Specify a start time, end time and a target temperature.
|
|
If the the current temperature is lower than the target temperature,
|
|
and the time is between start time and end time, the heater will
|
|
be turned on. Opposite if the the temperature is higher than the
|
|
target temperature the heater will be turned off.
|
|
|
|
If away mode is activated the target temperature is sat to a min
|
|
temperature (min_temp in config). The min temperature is also used
|
|
as target temperature when no other temperature is specified.
|
|
|
|
If the heater is manually turned on, the target temperature will
|
|
be sat to 100*C. Meaning
|
|
the thermostat probably will never turn off the heater.
|
|
If the heater is manually turned off, the target temperature will
|
|
be sat according to normal rules. (Based on target temperature
|
|
for given time intervals and the min temperature.)
|
|
|
|
A target temperature sat with the set_temperature function will
|
|
override all other rules for the target temperature.
|
|
|
|
```yaml
|
|
# Example configuration.yaml entry
|
|
thermostat:
|
|
platform: heat_control
|
|
name: Stue
|
|
|
|
# entity_id for heater switch, must be a toggle device
|
|
heater: switch.Ovn_stue
|
|
|
|
# entity_id for temperature sensor, target_sensor.state must be temperature
|
|
target_sensor: tellstick_sensor.Stue_temperature
|
|
|
|
# start_time-end_time:target_temp,
|
|
time_temp: 0700-0745:17,1500-1850:20
|
|
|
|
# minimum temperature, used when away mode is active or
|
|
# no other temperature specified.
|
|
min_temp: 10
|
|
```
|
|
|
|
For the example the heater will turn on at 0700 if the temperature
|
|
is lower than 17C away mode is false. Between 0700 and 0745 the
|
|
target temperature will be 17C. Between 0745 and 1500 no temperature
|
|
is specified. so the min_temp of 10C will be used. From 1500 to 1850
|
|
the target temperature is 20, but if away mode is true the target
|
|
temperature will be sat to 10C
|