title: Ness Alarm
|
|
description: Instructions on how to integrate a Ness D8x/D16x alarm system with Home Assistant.
|
|
ha_category:
|
|
- Alarm
|
|
- Binary sensor
|
|
ha_release: 0.85
|
|
ha_iot_class: Local Push
|
|
ha_codeowners:
|
|
- '@nickw444'
|
|
ha_domain: ness_alarm
|
|
ha_platforms:
|
|
- alarm_control_panel
|
|
- binary_sensor
|
|
ha_integration_type: integration
|
|
related:
|
|
- docs: /docs/configuration/
|
|
title: Configuration file
|
|
ha_quality_scale: legacy
|
|
---
|
|
|
|
The `ness_alarm` {% term integration %} will allow Home Assistant users who own a Ness D8x/D16x alarm system to leverage their alarm system and its sensors to provide Home Assistant with information about their homes. Connectivity between Home Assistant and the alarm is accomplished through a IP232 module that must be connected to the alarm.
|
|
|
|
There is currently support for the following device types within Home Assistant:
|
|
|
|
- Binary sensor: Reports on zone statuses
|
|
- Alarm control panel: Reports on alarm status, and can be used to arm/disarm the system
|
|
|
|
The module communicates via the [Ness D8x/D16x ASCII protocol](https://ia802202.us.archive.org/16/items/ness-d-8x-d-16x-serial-interface.-ascii-protocol/Ness%20D8x%20D16x%20Serial%20Interface.%20ASCII%20Protocol.pdf).
|
|
|
|
## Configuration
|
|
|
|
A `ness_alarm` section must be present in the {% term "`configuration.yaml`" %} file and contain the following options as required:
|
|
{% include integrations/restart_ha_after_config_inclusion.md %}
|
|
|
|
```yaml
|
|
# Example configuration.yaml entry
|
|
ness_alarm:
|
|
host: alarm.local
|
|
port: 2401
|
|
zones:
|
|
- name: Garage
|
|
id: 1
|
|
- name: Storeroom
|
|
id: 2
|
|
- name: Kitchen
|
|
id: 3
|
|
- name: Front Entrance
|
|
id: 4
|
|
- name: Front Door
|
|
id: 5
|
|
type: door
|
|
```
|
|
|
|
{% configuration %}
|
|
host:
|
|
description: The hostname of the IP232 module on your home network.
|
|
required: true
|
|
type: string
|
|
port:
|
|
description: The port on which the IP232 module listens for clients.
|
|
required: true
|
|
type: integer
|
|
scan_interval:
|
|
description: "Time interval between updates. Supported formats: `scan_interval: 'HH:MM:SS'`, `scan_interval: 'HH:MM'` and Time period dictionary (see example below)."
|
|
required: false
|
|
default: "00:01:00"
|
|
type: time
|
|
infer_arming_state:
|
|
description: Infer the disarmed arming state only via system status events. This works around a bug with some panels (`<v5.8`) which emit `update.status = []` when they are armed.
|
|
required: false
|
|
default: false
|
|
type: boolean
|
|
zones:
|
|
description: List of zones to add
|
|
required: false
|
|
type: list
|
|
keys:
|
|
zone_id:
|
|
description: ID of the zone on the alarm system (i.e Zone 1 -> Zone 16).
|
|
required: true
|
|
type: integer
|
|
name:
|
|
description: Name of the zone.
|
|
required: true
|
|
type: string
|
|
type:
|
|
description: The zone type. Can be any [binary_sensor device class](/integrations/binary_sensor/#device-class).
|
|
required: false
|
|
default: motion
|
|
type: string
|
|
{% endconfiguration %}
|
|
|
|
### Time period dictionary example
|
|
|
|
```yaml
|
|
scan_interval:
|
|
# At least one of these must be specified:
|
|
days: 0
|
|
hours: 0
|
|
minutes: 0
|
|
seconds: 10
|
|
milliseconds: 0
|
|
```
|
|
|
|
### Alarm System Configuration
|
|
|
|
As part of the installation process of the IP232 module, the device will need to be configured with the correct settings. From the [iComms Manual](https://ness.zendesk.com/hc/en-us/articles/360021989074-iComms-Manual), there are 3 essential steps:
|
|
1. Setting up the IP232 module with the correct baud rate (9600).
|
|
2. Ensuring connectivity of the device on either a DHCP assigned or Static IP address.
|
|
3. Setting the alarm panel up to allow for serial control. On D8x/D16x panels this is enabled by setting `P 199 E` `1E` to `6E` to be `ON` (6E available on v6 panels and later only).
|
|
|
|
If the settings in steps 1 and 2 are not set correctly, the integration will not be able to communicate properly with the device. If the `P 199 E` from step 3 is not configured properly, data will not be sent to the integration when events occur.
|
|
|
|
{% important %}
|
|
Incorrect configuration of these settings will prevent the integration from functioning properly.
|
|
{% endimportant %}
|
|
|
|
## Actions
|
|
|
|
### Action `aux`
|
|
|
|
Trigger an aux output. This requires PCB version 7.8 or higher.
|
|
|
|
| Data attribute | Optional | Description |
|
|
| ---------------------- | -------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
|
|
| `output_id` | No | The aux output you wish to change. A number from 1-8. |
|
|
| `state` | Yes | The On/Off State, represented as true/false. Default is true. If P14xE 8E is enabled then a value of true will pulse output x for the time specified in P14(x+4)E. |
|
|
|
|
### Action `panic`
|
|
|
|
Trigger a panic
|
|
|
|
| Data attribute | Optional | Description |
|
|
| ---------------------- | -------- | ------------------------------------------ |
|
|
| `code` | No | The user code to use to trigger the panic. |
|