title: Nobø Ecohub
|
|
description: Instructions on how to integrate Nobø Ecohub into Home Assistant.
|
|
ha_category:
|
|
- Climate
|
|
ha_release: '2022.10'
|
|
ha_iot_class: Local Push
|
|
ha_config_flow: true
|
|
ha_codeowners:
|
|
- '@echoromeo'
|
|
- '@oyvindwe'
|
|
ha_domain: nobo_hub
|
|
ha_platforms:
|
|
- climate
|
|
- select
|
|
- sensor
|
|
ha_integration_type: hub
|
|
---
|
|
|
|
Integrates [Nobø Ecohub](https://www.glendimplex.no/produkter/varmestyring/11123610/noboe-hub/c-77/p-330)
|
|
into Home Assistant. This integration is not officially supported or endorsed by Glen Dimplex Nordic AS,
|
|
and the authors/maintainers are not official partners of Glen Dimplex Nordic AS.
|
|
|
|
To configure the integration, you need the 3 last digits of the serial number of your hub. The serial number is located
|
|
on the back of the hub. If the hub is on a different network than Home Assistant (i.e., IoT VLAN or another routable network from Home Assistant), you also need to provide the IP address of the hub.
|
|
|
|
{% include integrations/config_flow.md %}
|
|
|
|
# Heaters
|
|
|
|
Each zone containing floor or wall mounted heaters is represented as an HVAC entity. Adding and removing zones
|
|
and heaters must be done using the Nobø Energy mobile app.
|
|
|
|
## Operation modes
|
|
|
|
Currently, you can see and change operation and preset for zones and set eco/comfort temperatures if you have
|
|
a thermostat that supports remote control of the temperature settings.
|
|
|
|
The possible operation modes are as follows:
|
|
|
|
- "Auto" - In this mode, the zone is in the default setting and preset shows which state the zone is in right now
|
|
(according to calendar setup).
|
|
- "Heat" - In this mode the zone is overridden and in the state selected by the preset ("Away", "Eco"
|
|
or "Comfort").
|
|
|
|
This can be utilized the following ways:
|
|
|
|
- Changing preset to "Away", "Eco", or "Comfort" will automatically change operation mode to "Heat".
|
|
- Changing preset to none will automatically change operation to "Auto" and update preset.
|
|
- Changing operation to "Auto" will automatically update preset.
|
|
- Changing operation to "Heat" will set preset to "Comfort".
|
|
|
|
### Preset override duration
|
|
|
|
By default, all overrides (when operation is not in "Auto" mode) are constant. It is possible to change this
|
|
to let overrides end when the week profile changes next (same as duration "Now" in the Nobø Energy mobile app)
|
|
in the integration configuration.
|
|
|
|
### Week profiles
|
|
|
|
The week profiles are retrieved from the hub. It is possible to change the current week profile for a zone
|
|
using a selector. Week profiles must be created and edited using the Nobø Energy mobile app.
|
|
|
|
### No preset "Off"
|
|
|
|
Nobø heaters do not support preset "Off". This is not a limitation of the integration, but a safety mechanism in the
|
|
Nobø system (perhaps related to frozen pipes due to frost in Nordic regions).
|
|
"Away" temperature is fixed to 7°C and cannot be altered. On/off receivers will be off when the zone is in "Away" status.
|
|
|
|
To turn heaters completely off, follow these steps (this is a workaround solution):
|
|
1. In the Nobø Energy mobile app, create a week profile.
|
|
- In this profile, set all days to state off.
|
|
2. To turn a zone off, select this week profile for the zone.
|
|
3. To turn a zone on again, switch to the normal week profile for the zone.
|
|
|
|
For more information, see the [Nobø Ecohub manual](https://help.nobo.no/en/user-manual/before-you-start/what-is-a-weekly-program/).
|
|
|
|
## Global override
|
|
|
|
To override all zones to a given preset (except the zones configured to not respect global override), use the global
|
|
override selector. Global override duration respects the same configuration as preset override duration.
|
|
|
|
# Nobø Switch
|
|
|
|
Each Nobø Switch (SW4) is represented as a temperature sensor. If a switch is linked to a zone, the temperature is
|
|
also available as the current temperature of the HVAC entity.
|