title: MELCloud
|
|
description: MELCloud integration
|
|
ha_category:
|
|
- Climate
|
|
ha_release: 0.106
|
|
ha_iot_class: Cloud Polling
|
|
ha_config_flow: true
|
|
ha_codeowners:
|
|
- '@vilppuvuorinen'
|
|
ha_domain: melcloud
|
|
---
|
|
|
|
The `melcloud` integration integrates Mitsubishi Electric's [MELCloud](https://www.melcloud.com/) enabled devices into Home Assistant.
|
|
|
|
## Device support
|
|
|
|
- Air-to-Air heat pumps, e.g., AC units - **Supported**
|
|
- Air-to-Water heat pumps - **Supported**
|
|
- Energy recovery ventilators - **Not supported**
|
|
- Other - **Not supported**
|
|
|
|
## Configuration
|
|
|
|
The integration should be configured through the user interface ("Configurations -> Integrations") using the MELCloud login details. While not optimal, **the provided password is not stored**.
|
|
|
|
An expired token needs to be updated manually by adding the MELCloud integration again with the same email address.
|
|
|
|
Configuration is also possible through `configuration.yaml`. The required authentication token can be found in `X-MitsContextKey` header when logged into the MELCloud. The language needs to be set to English and the "Remember me" option needs to be selected.
|
|
|
|
```yaml
|
|
melcloud:
|
|
username: xxxx@xxxxxxx
|
|
token: xxxxxxxxxxxxxxxxxxx
|
|
```
|
|
|
|
{% configuration %}
|
|
username:
|
|
description: Email address used to login to MELCloud
|
|
required: true
|
|
type: string
|
|
token:
|
|
description: X-MitsContextKey access token
|
|
required: true
|
|
type: string
|
|
{% endconfiguration %}
|
|
|
|
## Air-to-Air device
|
|
|
|
An Air-to-Air heat pump provides `climate` and `sensor` platforms. Device capabilities can limit the available parameters and sensors.
|
|
|
|
### Climate
|
|
|
|
The following parameters can be controlled for the `climate` platform entities:
|
|
|
|
- Power (using HVAC mode)
|
|
- Target temperature
|
|
- Operation mode (HVAC mode)
|
|
- Fan speed
|
|
- Horizontal and vertical vane positions
|
|
|
|
#### State attributes
|
|
|
|
|Attribute|Description|Example|
|
|
|---------|-----------|-------|
|
|
|`vane_horizontal` |Current horizontal vane position or mode|`auto`|
|
|
|`vane_horizontal_positions` |Available horizontal vane positions and modes|`auto, split, swing`|
|
|
|`vane_vertical` |Current vertical vane position or mode|`auto`|
|
|
|`vane_vertical_positions` |Available vertical vane positions and modes|`auto, split, swing`|
|
|
|
|
#### Controlling vanes
|
|
|
|
The horizontal and vertical vane positions can be controlled using the corresponding `melcloud.set_vane_horizontal` and `melcloud.set_vane_vertical` services.
|
|
|
|
Swing mode can also be used to control vertical vane position.
|
|
|
|
### Sensor
|
|
|
|
The following attributes are available for `sensor` platform entities:
|
|
|
|
- Room temperature
|
|
- Energy - The total consumed energy in kWh. **Not supported by all models.**
|
|
|
|
## Air-to-Water device
|
|
|
|
An Air-to-Water device provides `water_heater`, `climate` and `sensor` platforms.
|
|
|
|
### Climate
|
|
|
|
A `climate` platform entity is provided for each radiator zone in the air-to-water system. The following parameters can be controlled:
|
|
|
|
- Target room temperature
|
|
|
|
The radiators need to be configured to run in room temperature control mode either through the local HMI or MELCloud. Flow temperature and curve modes are not supported.
|
|
|
|
Some air-to-water devices allow cooling using the radiator zones. This feature has not been implemented due to the lack of sample devices.
|
|
|
|
The system cannot be turned on/off through the `climate` entities.
|
|
|
|
#### State attributes
|
|
|
|
|Attribute|Description|Example|
|
|
|---------|-----------|-------|
|
|
|`status` |Current operation status|`idle`|
|
|
|
|
### Sensor
|
|
|
|
The following attributes are available for `sensor` platform entities:
|
|
|
|
- Room temperature for each zone
|
|
- Tank water temperature
|
|
- Outside temperature - 1°C precision, polled every 1-2 hours.
|
|
- Zone flow temperature, polled every 1-2 hours
|
|
- Zone flow return temperature, polled every 1-2 hours
|
|
|
|
Unlike air-to-air devices, air-to-water devices do not report energy consumption in an easily accessible manner.
|
|
|
|
### Water heater
|
|
|
|
The following parameters can be controlled for the `water_heater` platform entities:
|
|
|
|
- Power - Controls the entire system.
|
|
- Target tank temperature
|
|
- Operation mode
|
|
|
|
#### State attributes
|
|
|
|
|Attribute|Description|Example|
|
|
|---------|-----------|-------|
|
|
|`status` |Current operation status|`heat`|
|