* Sets front matter defaults * Removes default front matter from section templates/pages * Removes default front matter from addon pages * Removes default front matter from integration pages * Removes default front matter from posts * Removes default front matter from docs pages * Removes default front matter from other pages * Fixes blog category pages
64 lines
1.7 KiB
Markdown
64 lines
1.7 KiB
Markdown
---
|
|
title: "Danfoss Air"
|
|
description: "How to integrate Danfoss Air HRV in Home Assistant."
|
|
ha_category:
|
|
- Climate
|
|
- Binary Sensor
|
|
- Sensor
|
|
- Switch
|
|
ha_release: 0.87
|
|
logo: danfoss_air.png
|
|
ha_iot_class: Local Polling
|
|
redirect_from:
|
|
- /components/binary_sensor.danfoss_air/
|
|
- /components/sensor.danfoss_air/
|
|
- /components/switch.danfoss_air/
|
|
---
|
|
|
|
The `danfoss_air` integration allows you to access information from your Danfoss Air HRV unit.
|
|
|
|
*Note*: Danfoss Air CCM only accepts one TCP connection at a time. Due to this the integration will not work while you have the HRV PC-Tool open.
|
|
|
|
There is currently support for the following device types within Home Assistant:
|
|
|
|
- [Binary sensor](#binary-sensor)
|
|
- [Sensor](#sensor)
|
|
- [Switch](#switch)
|
|
|
|
```yaml
|
|
# Example configuration.yaml entry
|
|
danfoss_air:
|
|
host: IP_ADDRESS_OF_CCM
|
|
```
|
|
|
|
{% configuration %}
|
|
host:
|
|
description: Danfoss Air CCM IP.
|
|
required: true
|
|
type: string
|
|
{% endconfiguration %}
|
|
|
|
## Binary sensor
|
|
|
|
The following binary sensor is supported.
|
|
|
|
- **Bypass active:** Indicator if heat recovery is currrently bypassed.
|
|
|
|
## Sensor
|
|
|
|
The following sensors are supported.
|
|
|
|
- **Outdoor temperature:** Outdoor air temperature.
|
|
- **Supply temperature:** Air temperature of the air supplied to the house.
|
|
- **Extract temperature:** Air temperature of the air extracted from the house.
|
|
- **Exhaust temperature:** Exhausted air temperature.
|
|
- **Remaining filter lifetime:** Reamining filter lifetime measured in percent.
|
|
|
|
## Switch
|
|
|
|
The following switches are supported.
|
|
|
|
- **Boost:** Switch to manually activate boost.
|
|
- **Bypass:** Switch to manually activate bypass.
|
|
- **Automatic bypass:** Switch to enable automatic bypass.
|