mirror of
https://github.com/home-assistant/home-assistant.io.git
synced 2025-06-01 07:46:49 +00:00

* Sets front matter defaults * Removes default front matter from section templates/pages * Removes default front matter from addon pages * Removes default front matter from integration pages * Removes default front matter from posts * Removes default front matter from docs pages * Removes default front matter from other pages * Fixes blog category pages
154 lines
4.4 KiB
Markdown
154 lines
4.4 KiB
Markdown
---
|
|
title: "Modbus"
|
|
description: "Instructions on how to integrate Modbus within Home Assistant."
|
|
logo: modbus.png
|
|
ha_category:
|
|
- Hub
|
|
ha_release: pre 0.7
|
|
ha_iot_class: Local Push
|
|
---
|
|
|
|
|
|
[Modbus](http://www.modbus.org/) is a serial communication protocol to control PLCs (Programmable logic controller).
|
|
It currently supports sensors and switches which can be controlled over serial, TCP, and UDP connections.
|
|
|
|
## Configuration
|
|
|
|
The configuration for adding modbus to your installation depends on the connection type, either a network or serial connection.
|
|
|
|
### Network connection
|
|
|
|
For a network connection, add the following to your `configuration.yaml` file:
|
|
|
|
```yaml
|
|
# Example configuration.yaml entry for a TCP connection
|
|
modbus:
|
|
name: hub1
|
|
type: tcp
|
|
host: IP_ADDRESS
|
|
port: 2020
|
|
```
|
|
|
|
{% configuration %}
|
|
type:
|
|
description: Type of the connection to Modbus. Possible values are `tcp` (Modbus TCP protocol according to "MODBUS Messaging Implementation Guide version 1.0b" provided by Schneider Automation.), `udp`(Modbus TCP form, but using UDP for transport. It removes the overheads required for TCP.) and `rtuovertcp` (Modbus RTU message transmitted with a TCP/IP wrapper and sent over a network instead of serial lines.).
|
|
required: true
|
|
type: string
|
|
host:
|
|
description: The IP address of your Modbus device, e.g., 192.168.1.1.
|
|
required: true
|
|
type: string
|
|
port:
|
|
description: The network port for the communication.
|
|
required: true
|
|
type: integer
|
|
name:
|
|
description: Name for this hub. Must be unique, so it is required when setting up multiple instances.
|
|
required: false
|
|
default: default
|
|
type: string
|
|
timeout:
|
|
description: Timeout for slave response in seconds.
|
|
required: false
|
|
default: 3
|
|
type: integer
|
|
{% endconfiguration %}
|
|
|
|
### Serial connection
|
|
|
|
For a serial connection, add the following to your `configuration.yaml` file:
|
|
|
|
```yaml
|
|
# Example configuration.yaml entry for a serial connection
|
|
modbus:
|
|
name: hub1
|
|
type: serial
|
|
method: rtu
|
|
port: /dev/ttyUSB0
|
|
baudrate: 9600
|
|
stopbits: 1
|
|
bytesize: 8
|
|
parity: N
|
|
```
|
|
|
|
{% configuration %}
|
|
type:
|
|
description: "Type of the connection to Modbus, needs to be `serial` for this setup."
|
|
required: true
|
|
type: string
|
|
method:
|
|
description: "Method of the connection to Modbus, either `rtu` or `ascii`."
|
|
required: true
|
|
type: string
|
|
port:
|
|
description: The port where your Modbus device is connected to your Home Assistant host.
|
|
required: true
|
|
type: string
|
|
baudrate:
|
|
description: The speed for the serial connection.
|
|
required: true
|
|
type: integer
|
|
stopbits:
|
|
description: "The stopbits for the serial connection, either `1` or `2`."
|
|
required: true
|
|
type: integer
|
|
bytesize:
|
|
description: "The bytesize for the serial connection; can be `5`, `6`, `7` or `8`."
|
|
required: true
|
|
type: integer
|
|
parity:
|
|
description: "The parity for the serial connection; can be `E`, `O` or `N`."
|
|
required: true
|
|
type: string
|
|
name:
|
|
description: Name for this hub. Must be unique, so it is required when setting up multiple instances.
|
|
required: false
|
|
default: default
|
|
type: string
|
|
timeout:
|
|
description: Timeout for slave response in seconds.
|
|
required: false
|
|
default: 3
|
|
type: integer
|
|
{% endconfiguration %}
|
|
|
|
### Multiple connections
|
|
|
|
Multiple connections are possible, add something like the following to your `configuration.yaml` file:
|
|
|
|
```yaml
|
|
# Example configuration.yaml entry for multiple TCP connections
|
|
modbus:
|
|
- type: tcp
|
|
host: IP_ADDRESS_1
|
|
port: 2020
|
|
name: hub1
|
|
|
|
- type: tcp
|
|
host: IP_ADDRESS_2
|
|
port: 501
|
|
name: hub2
|
|
```
|
|
|
|
### Services
|
|
|
|
|
|
| Service | Description |
|
|
| ------- | ----------- |
|
|
| write_register | Write register. Requires `hub`, `unit`, `address` and `value` fields. `value` can be either single value or an array |
|
|
|
|
#### Service Data Attributes
|
|
|
|
| Attribute | Description |
|
|
| --------- | ----------- |
|
|
| name | Hub name (defaults to 'default' when omitted) |
|
|
| unit | Slave address (set to 255 you talk to Modbus via TCP) |
|
|
| address | Address of the Register (e.g., 138) |
|
|
| value | A single value or an array of 16-bit values. Single value will call modbus function code 6. Array will call modbus function code 16. Array might need reverse ordering. E.g., to set 0x0004 you might need to set `[4,0]` |
|
|
|
|
## Building on top of Modbus
|
|
|
|
- [Modbus Binary Sensor](/components/binary_sensor.modbus/)
|
|
- [Modbus Sensor](/components/sensor.modbus/)
|
|
- [Modbus Switch](/components/switch.modbus/)
|