TED5000 electricity monitoring How to add a TED5000 to Home Assistant. ted.png
Energy
0.30 Local Polling
/components/sensor.ted5000/

The ted 5000 monitors electricity consumption/production by connecting to the TED gateway, itself connected to one or several Measuring Transmitting Units (MTU). The platform creates up to two sensors per MTU, one for Wattage the other for Voltage.

If you want to enable the ted5000 sensor, add the following lines to your configuration.yaml:

# Example configuration.yaml entry
sensor:
  - platform: ted5000
    host: 192.168.1.100

{% configuration %} host: description: The IP address of your ted gateway. required: true type: string port: description: The port of your ted gateway. required: false type: integer default: 80 name: description: Name of the ted gateway. required: false type: string default: ted {% endconfiguration %}

For each plugged MTU, using an index starting at 1, the platform creates 2 sensors:

sensor.<name>_mtu<MTU id>_power
sensor.<name>_mtu<MTU id>_voltage