[Modbus](http://www.modbus.org/) is a serial communication protocol to control PLCs (Programmable logic controller). It currently supports sensors and switches which can be controlled over serial, TCP, and UDP connections.
To add modbus to your installation, add the following to your `configuration.yaml` file:
For a network connection:
```yaml
# Example configuration.yaml entry for a TCP connection
modbus:
type: tcp
host: IP_ADDRESS
port: 2020
```
Configuration variables:
- **type** (*Required*): Type of the connection to Modbus.
- **host** (*Required*): The IP address of your Modbus device, eg. 192.168.1.1.
- **port** (*Required*): The port for the communication.
- **timeout** (*Optional*): Timeout for slave response in seconds. (default: 3)
For a serial connection:
```yaml
# Example configuration.yaml entry for a serial connection
modbus:
type: serial
method: rtu
port: /dev/ttyUSB0
baudrate: 9600
stopbits: 1
bytesize: 8
parity: N
```
Configuration variables:
- **type** (*Required*): Type of the connection to Modebus.
- **method** (*Required*): Method of the connection to Modbus.
- **port** (*Required*): The port where your Modbus device is connected to your Home Assistant host.
- **baudrate** (*Required*): The speed for the serial connection.
- **stopbits** (*Required*): The stopbits for the serial connection.
- **bytesize** (*Required*): The bytesize for the serial connection.
- **parity** (*Required*): The parity for the serial connection.
- **timeout** (*Optional*): Timeout for slave response in seconds. (default: 3)
### {% linkable_title Services %}
| Service | Description |
| ------- | ----------- |
| write_register | Write register. Requires `unit`, `address` and `value` fields. `value` can be either single value or an array |
## {% linkable_title Building on top of Modbus %}
- [Modbus Binary Sensor](/components/binary_sensor.modbus/)
- [Modbus Sensor](/components/sensor.modbus/)
- [Modbus Switch](/components/switch.modbus/)