The knx
climate platform is used as in interface with KNX thermostats.
The knx
component must be configured correctly, see KNX Component.
To use your KNX thermostats in your installation, add the following lines to your configuration.yaml
file:
climate:
- platform: knx
name: HASS-Kitchen.Temperature
temperature_address: '6/2/1'
setpoint_address: '5/1/2'
target_temperature_address: '5/1/1'
operation_mode_address: '5/1/3'
Alternatively, if your device has dedicated binary group addresses for frost/night/comfort mode:
climate:
- platform: knx
name: HASS-Kitchen.Temperature
temperature_address: '6/2/1'
setpoint_address: '5/1/2'
target_temperature_address: '5/1/1'
operation_mode_frost_protection_address: '5/1/3'
operation_mode_night_address: '5/1/4'
operation_mode_comfort_address: '5/1/5'
-
name (Optional): A name for this device used within Home Assistant.
-
temperature_address: KNX group address for reading current room temperature from KNX bus.
-
target_temperature_address: KNX group address for reading current target temperature from KNX bus.
-
setpoint_address: KNX group address for basis setpoint
-
operation_mode_address (Optional) KNX address for operation mode (Frost protection/night/comfort).
-
operation_mode_state_address (Optional) Explicit KNX address for reading operation mode
-
controller_status_address (Optional) KNX address for HVAC controller status (in accordance with KNX AN 097/07 rev 3)
-
controller_status_state_address (Optional) Explicit KNX address for reading HVAC controller status
-
operation_mode_frost_protection_address (Optional) KNX address for switching on/off frost/heat protection mode.
-
operation_mode_night_address (Optional) KNX address for switching on/off night nmode.
-
operation_mode_comfort_address (Optional) KNX address for switching on/off comfort mode.
operation_mode_frost_protection_address
/ operation_mode_night_address
/ operation_mode_comfort_address
are not necessary if operation_mode_address
was specified.