Integrates MySensors switches into Home Assistant. See the [main component] for configuration instructions.
|
|
|
|
The following actuator types are supported:
|
|
|
|
##### MySensors version 1.4 and higher
|
|
|
|
S_TYPE | V_TYPE
|
|
---------|-------------------
|
|
S_DOOR | V_ARMED
|
|
S_MOTION | V_ARMED
|
|
S_SMOKE | V_ARMED
|
|
S_LIGHT | V_LIGHT
|
|
S_LOCK | V_LOCK_STATUS
|
|
S_IR | V_IR_SEND, V_LIGHT
|
|
|
|
##### MySensors version 1.5 and higher
|
|
|
|
S_TYPE | V_TYPE
|
|
-------------|----------------------
|
|
S_LIGHT | V_STATUS
|
|
S_BINARY | [V_STATUS or V_LIGHT]
|
|
S_SPRINKLER | V_STATUS
|
|
S_WATER_LEAK | V_ARMED
|
|
S_SOUND | V_ARMED
|
|
S_VIBRATION | V_ARMED
|
|
S_MOISTURE | V_ARMED
|
|
|
|
##### MySensors version 2.0 and higher
|
|
|
|
S_TYPE | V_TYPE
|
|
----------------|---------
|
|
S_WATER_QUALITY | V_STATUS
|
|
|
|
All V_TYPES for each S_TYPE above are required to activate the actuator for the platform. Use either V_LIGHT or V_STATUS depending on library version for cases where that V_TYPE is required.
|
|
|
|
For more information, visit the [serial api] of MySensors.
|
|
|
|
### {% linkable_title Services %}
|
|
|
|
The MySensors switch platform exposes a service to change an IR code attribute for an IR switch device and turn the switch on. The IR switch will automatically be turned off after being turned on, if `optimistic` is set to `true` in the [config](/components/mysensors/#configuration) for the MySensors component. This will simulate a push button on a remote. If `optimistic` is `false`, the MySensors device will have to report its updated state to reset the switch. See the [example sketch](#ir-switch-sketch) for the IR switch below.
|
|
|
|
| Service | Description |
|
|
| ------- | ----------- |
|
|
| mysensors_send_ir_code | Set an IR code as a state attribute for a MySensors IR device switch and turn the switch on.|
|
|
|
|
The service can be used as part of an automation script. For example:
|
|
|
|
```yaml
|
|
# Example configuration.yaml automation entry
|
|
automation:
|
|
- alias: turn hvac on
|
|
trigger:
|
|
platform: time
|
|
at: '5:30:00'
|
|
action:
|
|
service: switch.mysensors_send_ir_code
|
|
entity_id: switch.hvac_1_1
|
|
data:
|
|
V_IR_SEND: '0xC284' # the IR code to send
|
|
|
|
- alias: turn hvac off
|
|
trigger:
|
|
platform: time
|
|
at: '0:30:00'
|
|
action:
|
|
service: switch.mysensors_send_ir_code
|
|
entity_id: switch.hvac_1_1
|
|
data:
|
|
V_IR_SEND: '0xC288' # the IR code to send
|
|
```
|
|
|
|
### {% linkable_title Example sketches %}
|
|
|
|
#### {% linkable_title Switch sketch %}
|
|
```cpp
|
|
/*
|
|
* Documentation: http://www.mysensors.org
|
|
* Support Forum: http://forum.mysensors.org
|
|
*
|
|
* http://www.mysensors.org/build/relay
|
|
*/
|
|
|
|
#include <MySensor.h>
|
|
#include <SPI.h>
|
|
|
|
#define SN "Relay"
|
|
#define SV "1.0"
|
|
#define CHILD_ID 1
|
|
#define RELAY_PIN 3
|
|
|
|
MySensor gw;
|
|
MyMessage msgRelay(CHILD_ID, V_STATUS);
|
|
|
|
void setup()
|
|
{
|
|
gw.begin(incomingMessage);
|
|
gw.sendSketchInfo(SN, SV);
|
|
// Initialize the digital pin as an output.
|
|
pinMode(RELAY_PIN, OUTPUT);
|
|
gw.present(CHILD_ID, S_BINARY);
|
|
gw.send(msgRelay.set(0));
|
|
}
|
|
|
|
void loop()
|
|
{
|
|
gw.process();
|
|
}
|
|
|
|
void incomingMessage(const MyMessage &message)
|
|
{
|
|
if (message.type == V_STATUS) {
|
|
// Change relay state.
|
|
digitalWrite(RELAY_PIN, message.getBool() ? 1 : 0);
|
|
gw.send(msgRelay.set(message.getBool() ? 1 : 0));
|
|
}
|
|
}
|
|
```
|
|
|
|
#### {% linkable_title IR switch sketch %}
|
|
```cpp
|
|
/*
|
|
* Documentation: http://www.mysensors.org
|
|
* Support Forum: http://forum.mysensors.org
|
|
*
|
|
* http://www.mysensors.org/build/ir
|
|
*/
|
|
|
|
#include <MySensor.h>
|
|
#include <SPI.h>
|
|
#include <IRLib.h>
|
|
|
|
#define SN "IR Sensor"
|
|
#define SV "1.0"
|
|
#define CHILD_ID 1
|
|
|
|
MySensor gw;
|
|
|
|
char code[10] = "abcd01234";
|
|
char oldCode[10] = "abcd01234";
|
|
MyMessage msgCodeRec(CHILD_ID, V_IR_RECEIVE);
|
|
MyMessage msgCode(CHILD_ID, V_IR_SEND);
|
|
MyMessage msgSendCode(CHILD_ID, V_LIGHT);
|
|
|
|
void setup()
|
|
{
|
|
gw.begin(incomingMessage);
|
|
gw.sendSketchInfo(SN, SV);
|
|
gw.present(CHILD_ID, S_IR);
|
|
// Send initial values.
|
|
gw.send(msgCodeRec.set(code));
|
|
gw.send(msgCode.set(code));
|
|
gw.send(msgSendCode.set(0));
|
|
}
|
|
|
|
void loop()
|
|
{
|
|
gw.process();
|
|
// IR receiver not implemented, just a dummy report of code when it changes
|
|
if (String(code) != String(oldCode)) {
|
|
Serial.print("Code received ");
|
|
Serial.println(code);
|
|
gw.send(msgCodeRec.set(code));
|
|
strcpy(oldCode, code);
|
|
}
|
|
}
|
|
|
|
void incomingMessage(const MyMessage &message) {
|
|
if (message.type==V_LIGHT) {
|
|
// IR sender not implemented, just a dummy print.
|
|
if (message.getBool()) {
|
|
Serial.print("Sending code ");
|
|
Serial.println(code);
|
|
}
|
|
gw.send(msgSendCode.set(message.getBool() ? 1 : 0));
|
|
// Always turn off device
|
|
gw.wait(100);
|
|
gw.send(msgSendCode.set(0));
|
|
}
|
|
if (message.type == V_IR_SEND) {
|
|
// Retrieve the IR code value from the incoming message.
|
|
String codestring = message.getString();
|
|
codestring.toCharArray(code, sizeof(code));
|
|
Serial.print("Changing code to ");
|
|
Serial.println(code);
|
|
gw.send(msgCode.set(code));
|
|
}
|
|
}
|
|
```
|
|
|
|
[main component]: /components/mysensors/
|
|