page Modbus Binary Sensor Instructions on how to set up Modbus binary sensors within Home Assistant. 2016-09-13 12:02 true false true true modbus.png Binary Sensor 0.28

The modbus binary sensor allows you to gather data from Modbus coils.

To use your Modbus binary sensors in your installation, add the following to your configuration.yaml file:

# Example configuration.yml entry
binary_sensor:
  platform: modbus
  coils:
    - name: Sensor1
      slave: 1
      coil: 100
    - name: Sensor2
      slave: 1
      coil: 110

Configuration variables:

  • coils array (Required): The array contains a list of coils to read from.
    • name (Required): Name of the sensor.
    • slave (Required): The number of the slave (Optional for tcp and upd Modbus).
    • coil (Required): Coil number.