Control and monitor your APsystems EZ1 microinverters locally without the cloud
Local Polling
true
2024.6
Energy
apsystems
binary_sensor
number
sensor
switch
device
@mawoka-myblock
@SonnenladenGmbH
The APsystems {% term integration %} allows you to read the data from your APsystems EZ1 microinverter. It also allows you to set the output limit to anything above 30 watts.
Sensors
Numerical sensors
Sensor ID
Unit
Description
total_power
W
Total current output of the inverter
lifetime_production_p1
kWh
Lifetime production of first input
lifetime_production_p2
kWh
Lifetime production of second input
lifetime_production
kWh
Lifetime production of both inputs combined
total_power_p1
W
Current input on first input
total_power_p2
W
Current input on second input
today_production
kWh
Today's production of both inputs combined
today_production_p1
kWh
Today's production of first input
today_production_p2
kWh
Today's production of second input
Binary sensors
Sensor ID
Description
off_grid_status
On when the inverter is not connected to the power grid
dc_1_short_circuit_error_status
Short circuit detected on first input
dc_2_short_circuit_error_status
Short circuit detected on second input
output_fault_status
Output because of any error deactivated
Settings
Setting ID
Type
Description
inverter_status
switch
Enables or disables the inverter's output
output_limit
number
Sets the max output of the inverter
Prerequisites