2025-02-05 13:46:37 +01:00

7.2 KiB

title, description, ha_category, ha_release, ha_iot_class, ha_config_flow, ha_codeowners, ha_domain, ha_platforms, ha_integration_type
title description ha_category ha_release ha_iot_class ha_config_flow ha_codeowners ha_domain ha_platforms ha_integration_type
VeSync Instructions on how to set up VeSync switches, outlets, and fans within Home Assistant.
Fan
Light
Number
Switch
0.66 Cloud Polling true
@markperdue
@webdjoe
@thegardenmonkey
@cdnninja
@iprak
vesync
binary_sensor
diagnostics
fan
humidifier
light
number
sensor
switch
integration

The VeSync {% term integration %} enables you to control smart switches and outlets connected to the VeSync App.

The devices must be added to the VeSync App before this {% term integration %} can discover them.

The following platforms are supported:

  • fan
  • humidifier
  • light
  • number
  • sensor
  • switch

Supported devices

This {% term integration %} supports devices controllable by the VeSync App. The following devices are supported by this {% term integration %}:

Bulbs

  • Etekcity WiFi Dimmable LED Bulb (ESL100)
  • Etekcity WiFi Dimmable and Tunable White LED Bulb (ESL100CW)

Wall switches

  • Etekcity In Wall Smart Switch (EWSL01-USA)
  • Etekcity Wifi Dimmer Switch (ESD16)
  • Etekcity Wifi Dimmer Switch (ESWD16)

Outlet plugs

  • Etekcity 7 Amp US outlet - ESW01-USA (Round)
  • Etekcity 10 Amp US outlet - ESW10-USA (Round)
  • Etekcity 10 Amp EU outlet - ESW10-EU (Round)
  • Etekcity 15 Amp US outlet - ESW15-USA (Rectangular)
  • Etekcity 2 Plug Outdoor Outlet - ESO15-TB

Fans

  • Core 200S: Smart True HEPA Air Purifier
  • Core 300S: Smart True HEPA Air Purifier
  • Core 400S: Smart True HEPA Air Purifier
  • Core 600S: Smart True HEPA Air Purifier
  • EverestAir: Smart Air Purifier
  • Vital 100S Smart True HEPA Air Purifier (LAP-V102S-WUS)
  • Vital 200S Smart True HEPA Air Purifier (LAP-V201S-WUS)
  • LEVOIT Smart Wifi Air Purifier (LV-PUR131S)
  • LEVOIT Smart Tower Fan (LTF-F422S-WUS)

Humidifiers

  • Classic200S: Classic 200S Smart Ultrasonic Cool Mist Humidifier
  • Classic300S: Classic 300S Ultrasonic Smart Humidifier

Prerequisite

Before you can use this {% term integration %}, all devices must be registered with the VeSync App. Once registration is complete, continue with the steps described in the configuration section below.

{% include integrations/config_flow.md %}

Actions

Action Description
update_devices Poll Vesync server to find and add any new devices

Power & energy sensors

Many VeSync outlets support power & energy monitoring. This data is exposed as sensor entities alongside the outlet itself. Note that prior versions of the {% term integration %} exposed these as state attributes on the outlet switch {% term entity %}.

Sensor Description Example
sensor.<outlet name>_current_power The present power consumption of the switch in watts 7.89
sensor.<outlet name>_energy_use_today The kilowatt hours used by the switch during the previous 24 hours 0.12
sensor.<outlet name>_voltage The present voltage of the switch in Volts as a diagnostic sensor 120.32
sensor.<outlet name>_energy_use_weekly Total energy usage for week starting from Monday 12:01AM in kWh 14.74
sensor.<outlet name>_energy_use_monthly Total energy usage for month starting from 12:01AM on the first in kWh 52.30
sensor.<outlet name>_energy_use_yearly Total energy usage for year start from 12:01AM on Jan 1 in kWh 105.25

Fan & air quality sensors

All VeSync air purifiers expose the remaining filter lifetime, and some also expose air quality measurements.

Sensor Description Example
filter_life Remaining percentage of the filter. (LV-PUR131S, Core200S/300s/400s/600s/EverestAir) 142
air_quality The current air quality reading. (LV-PUR131S, Core300s/400s/600s) excellent
pm2_5 The current air quality reading. (Core300s/400s/600s/EverestAir) 8

Fan exposed attributes

VeSync air purifiers will expose the following details depending on the features supported by the model:

Attribute Description Example
mode The current mode the device is in. (LV-PUR131S, Core200S/300s/400s) manual
speed The current speed setting of the device. (LV-PUR131S, Core200S/300s/400s) high
speed_list The available list of speeds supported by the device. (LV-PUR131S) high
active_time The number of seconds since the device has been in a non-off mode. (LV-PUR131S) 1598
screen_status The current status of the screen. (LV-PUR131S) on
night_light The current status of the night light (Core200S/Core400s) off
child_lock The current status of the child lock (Core200S/300s/400s) off

Humidifier

Sensors and settings exposed by VeSync humidifiers.

Sensor Description Example
humidity Current humidity (in %) 35
Number Description Example
mist_level Mist level intensity (Range: 1-9, Step: 1) 1

Extracting attribute data

In order to get the attributes readings from supported devices, such as voltage from outlets or fan attributes, you'll have to create a template sensor.

In the example below, change all of the vesync_switch's to match your device's entity ID.

Adapted from the TP-Link integration.

{% raw %}

template:
  - sensor:
    - name: "Vesync voltage"
      state: "{{ state_attr('switch.vesync_switch', 'voltage') | float(default=0) }}"