* explain integration methods * Update source/_integrations/integration.markdown Co-authored-by: Christian Adamini <christian.adamini@invision.de> * spelling Co-authored-by: Danny Tsang <567982+dannytsang@users.noreply.github.com> * grammar Co-authored-by: Danny Tsang <567982+dannytsang@users.noreply.github.com> --------- Co-authored-by: Christian Adamini <christian.adamini@invision.de> Co-authored-by: Danny Tsang <567982+dannytsang@users.noreply.github.com>
134 lines
5.4 KiB
Markdown
134 lines
5.4 KiB
Markdown
---
|
|
title: Integration - Riemann sum integral
|
|
description: Instructions on how to integrate Integration Sensor into Home Assistant.
|
|
ha_category:
|
|
- Energy
|
|
- Helper
|
|
- Sensor
|
|
- Utility
|
|
ha_release: 0.87
|
|
ha_iot_class: Local Push
|
|
ha_quality_scale: internal
|
|
ha_codeowners:
|
|
- '@dgomes'
|
|
ha_domain: integration
|
|
ha_config_flow: true
|
|
ha_platforms:
|
|
- sensor
|
|
ha_integration_type: helper
|
|
---
|
|
|
|
This integrations provides the [Riemann sum](https://en.wikipedia.org/wiki/Riemann_sum)
|
|
of the values provided by a source sensor. The Riemann sum is an approximation
|
|
of an **integral** by a finite sum.
|
|
|
|
The integration sensors are updated upon changes of the **source**. Fast
|
|
sampling source sensors provide more accurate results. In this implementation, the
|
|
default is the Trapezoidal method, but Left and Right methods can optionally
|
|
be used.
|
|
|
|
{% include integrations/config_flow.md %}
|
|
{% configuration_basic %}
|
|
Name:
|
|
description: The name the sensor should have. You can change it again later.
|
|
Input sensor:
|
|
description: The entity providing numeric readings to integrate.
|
|
Integral method:
|
|
description: Riemann sum method to be used.
|
|
Precision:
|
|
description: Round the calculated integration value to at most N decimal places.
|
|
Metric prefix:
|
|
description: Metric unit to prefix the integration result.
|
|
Integration time:
|
|
description: SI unit of time to integrate over.
|
|
{% endconfiguration_basic %}
|
|
|
|
|
|
## YAML configuration
|
|
|
|
Alternatively, this integration can be configured and set up manually via YAML
|
|
as well. To enable the Integration sensor in your installation, add the
|
|
following to your `configuration.yaml` file:
|
|
|
|
```yaml
|
|
# Example configuration.yaml entry
|
|
sensor:
|
|
- platform: integration
|
|
source: sensor.current_power
|
|
```
|
|
|
|
{% configuration %}
|
|
source:
|
|
description: The entity ID of the sensor providing numeric readings.
|
|
required: true
|
|
type: string
|
|
name:
|
|
description: Name to use in the frontend.
|
|
required: false
|
|
default: source entity ID integral
|
|
type: string
|
|
unique_id:
|
|
description: An ID that uniquely identifies the integration sensor. Set this to a unique value to allow customization through the UI.
|
|
required: false
|
|
type: string
|
|
round:
|
|
description: Round the calculated integration value to at most N decimal places.
|
|
required: false
|
|
default: 3
|
|
type: integer
|
|
unit_prefix:
|
|
description: "Metric unit to prefix the integration result. Available units are `k`, `M`, `G` and `T`."
|
|
required: false
|
|
default: None
|
|
type: string
|
|
unit_time:
|
|
description: "SI unit of time to integrate over. Available units are `s`, `min`, `h` and `d`."
|
|
required: false
|
|
default: h
|
|
type: string
|
|
method:
|
|
description: "Riemann sum method to be used. Available methods are `trapezoidal`, `left` and `right`."
|
|
required: false
|
|
type: string
|
|
default: trapezoidal
|
|
{% endconfiguration %}
|
|
|
|
In case you expect that your source sensor will provide several subsequent values that are equal, you should opt for the `left` method to get accurate readings.
|
|
|
|
The unit of `source` together with `unit_prefix` and `unit_time` is used to generate a unit for the integral product (e.g. a source in `W` with prefix `k` and time `h` would result in `kWh`). Note that `unit_prefix` and `unit_time` are _also_ relevant to the Riemann sum calculation.
|
|
|
|
## Integration method
|
|
|
|
Riemann Sum is a approximation of an integral by a finite sum and is therefore intrinsically inaccurate, nonetheless, depending on the method used, values can be more or less accurate.
|
|
|
|
Regardless of the method used the integration will be more accurate if the source updates more often. If your source is not updated, neither will the Riemann Sum sensor, as all this integration does is calculate the next step in the event of a source update.
|
|
|
|
### Trapezoidal
|
|
|
|
The `trapezoidal` method follows the [Trapezoidal rule](https://en.wikipedia.org/wiki/Trapezoidal_rule). This method is the most accurate of the currently implemented methods, **if** the source updates often, since it better fits the curve of the intrinsic source.
|
|
|
|
### Left
|
|
|
|
The `left` method follows the [Left rule](https://en.wikipedia.org/wiki/Riemann_sum#Left_rule). The method **underestimates** the intrinsic source, but is extremely accurate at estimating rectangular functions which are very stable for long periods of time and change very rapidly (e.g. such as the power function of a resistive load can jump instantly to a given value and stay at the same value for hours). If your source keeps its state for long periods of time, this method is preferable to the `trapezoidal`.
|
|
|
|
### Right
|
|
|
|
The `right` method follows the [Right rule](https://en.wikipedia.org/wiki/Riemann_sum#Right_rule). The method is similar to the left method, but **overestimates** the intrinsic source. Again it is only appropriate to be used with rectangular functions.
|
|
|
|
## Energy
|
|
|
|
An integration sensor is quite useful in energy billing scenarios since energy is generally billed in kWh and many sensors provide power in W (Watts).
|
|
|
|
If you have a sensor that provides you with power readings in Watts (uses W as `unit_of_measurement`, `device_class` of `power`), then you can use the `integration` sensor to track how much energy is being spent. Take the next manual YAML configuration as an example:
|
|
|
|
```yaml
|
|
sensor:
|
|
- platform: integration
|
|
source: sensor.current_power
|
|
name: energy_spent
|
|
unit_prefix: k
|
|
round: 2
|
|
```
|
|
|
|
This configuration will provide you with `sensor.energy_spent` which will have your energy in kWh, as a `device_class` of `energy`.
|