Markdown
---
|
|
title: IamMeter
|
|
description: Instructions on how to integrate IAMMETER sensor within Home Assistant.
|
|
ha_category:
|
|
- Energy
|
|
- Sensor
|
|
ha_release: 0.107
|
|
ha_iot_class: Local Polling
|
|
ha_domain: iammeter
|
|
ha_codeowners:
|
|
- '@lewei50'
|
|
ha_platforms:
|
|
- sensor
|
|
ha_integration_type: integration
|
|
---
|
|
|
|
[IAMMETER](https://www.iammeter.com/) provides both a bi-directional single-phase energy meter([WEM3080](https://www.iammeter.com/products/single-phase-meter)) and a bi-directional three-phase energy monitor ([WEM3080T](https://www.iammeter.com/products/three-phase-meter)). Both of them can be integrated into Home Assistant.
|
|
|
|
|
|
## Configuration
|
|
|
|
To use this sensor in your installation, add the following to your `configuration.yaml` file:
|
|
|
|
```yaml
|
|
# Example configuration.yaml entry
|
|
sensor:
|
|
- platform: iammeter
|
|
host: IP_ADDRESS_OF_HOST
|
|
```
|
|
|
|
{% configuration %}
|
|
host:
|
|
description: The IP address of your IAMMETER.
|
|
required: true
|
|
type: string
|
|
port:
|
|
description: port of your IAMMETER.
|
|
required: false
|
|
default: 80
|
|
type: integer
|
|
name:
|
|
description: Name for the sensor entity.
|
|
required: false
|
|
type: string
|
|
default: IamMeter
|
|
{% endconfiguration %}
|
|
|
|
## Sensors
|
|
|
|
Sensors available in the library:
|
|
|
|
### Single-phase energy meter (WEM3080/WEM3162)
|
|
|
|
| name | Unit | Description |
|
|
| -------------------- | ---- | :--------------------------- |
|
|
| wem3080_voltage | V | Voltage. |
|
|
| wem3080_current | A | current. |
|
|
| wem3080_power | W | active power. |
|
|
| wem3080_importenergy | kWh | Energy consumption from grid |
|
|
| wem3080_exportgrid | kWh | Energy export to grid |
|
|
|
|
### Three-phase energy meter (WEM3080T)
|
|
|
|
| name | Unit | Description |
|
|
| ----------------------- | ---- | :-------------------- |
|
|
| wem3080t_voltage_a | V | A phase voltage |
|
|
| wem3080t_current_a | A | A phase current |
|
|
| wem3080t_power_a | W | A phase active power |
|
|
| wem3080t_importenergy_a | kWh | A phase import energy |
|
|
| wem3080t_exportgrid_a | kWh | A phase export energy |
|
|
| wem3080t_frequency_a | Hz | A phase frequency |
|
|
| wem3080t_pf_a | | A phase power factor |
|
|
| | | |
|
|
| wem3080t_voltage_b | V | B phase voltage |
|
|
| wem3080t_current_b | A | B phase current |
|
|
| wem3080t_power_b | W | B phase active power |
|
|
| wem3080t_importenergy_b | kWh | B phase import energy |
|
|
| wem3080t_exportgrid_b | kWh | B phase export energy |
|
|
| wem3080t_frequency_b | Hz | B phase frequency |
|
|
| wem3080t_pf_b | | B phase power factor |
|
|
| | | |
|
|
| wem3080t_voltage_c | V | C phase voltage |
|
|
| wem3080t_current_c | A | C phase current |
|
|
| wem3080t_power_c | W | C phase active power |
|
|
| wem3080t_importenergy_c | kWh | C phase import energy |
|
|
| wem3080t_exportgrid_c | kWh | C phase export energy |
|
|
| wem3080t_frequency_c | Hz | C phase frequency |
|
|
| wem3080t_pf_c | | C phase power factor |
|