title: Min/Max
|
|
description: Instructions on how to integrate min/max sensors into Home Assistant.
|
|
ha_category:
|
|
- Utility
|
|
- Sensor
|
|
ha_iot_class: Local Polling
|
|
ha_release: 0.31
|
|
ha_quality_scale: internal
|
|
ha_codeowners:
|
|
- '@fabaff'
|
|
ha_domain: min_max
|
|
---
|
|
|
|
The `min_max` sensor platform consumes the state from other sensors to determine the minimum, maximum, latest (last), mean and median of the collected states. The sensor will always show you the lowest/highest/latest value which was received from all monitored sensors. If you have spikes in your values, it's recommended to filter/equalize your values with a [statistics sensor](/integrations/statistics) first.
|
|
|
|
This sensor is an alternative to the [template sensor](/integrations/template)'s `value_template:` to get the average or the median of multiple sensors.
|
|
|
|
{% raw %}
|
|
```yaml
|
|
{{ ((float(states('sensor.kitchen_temperature')) +
|
|
float(states('sensor.living_room_temperature')) +
|
|
float(states('sensor.office_temperature'))) / 3) | round(2)
|
|
}}
|
|
```
|
|
{% endraw %}
|
|
|
|
Sensors with an unknown state will be ignored in the calculation. If the unit of measurement of the sensors differs, the `min_max` sensor will go to an error state where the value is `UNKNOWN` and unit of measurement is `ERR`.
|
|
|
|
## Configuration
|
|
|
|
To enable the `min_max` sensor, add the following lines to your `configuration.yaml`:
|
|
|
|
```yaml
|
|
# Example configuration.yaml entry
|
|
sensor:
|
|
- platform: min_max
|
|
entity_ids:
|
|
- sensor.kitchen_temperature
|
|
- sensor.living_room_temperature
|
|
- sensor.office_temperature
|
|
```
|
|
|
|
{% configuration %}
|
|
entity_ids:
|
|
description: At least two entities to monitor. The unit of measurement of the first entry will be the one that's used. All entities must use the same unit of measurement.
|
|
required: true
|
|
type: [list, string]
|
|
type:
|
|
description: "The type of sensor: `min`, `max`, `last`, `mean` or `median`."
|
|
required: false
|
|
default: max
|
|
type: string
|
|
name:
|
|
description: Name of the sensor to use in the frontend.
|
|
required: false
|
|
type: string
|
|
round_digits:
|
|
description: Round mean or median value to specified number of digits.
|
|
required: false
|
|
type: integer
|
|
default: 2
|
|
{% endconfiguration %}
|