title: apcupsd
|
|
description: Instructions on how to integrate apcupsd status with Home Assistant.
|
|
logo: apcupsd.png
|
|
ha_category:
|
|
- System Monitor
|
|
- Binary Sensor
|
|
- Sensor
|
|
ha_release: 0.13
|
|
ha_iot_class: Local Polling
|
|
ha_domain: apcupsd
|
|
ha_platforms:
|
|
- binary_sensor
|
|
- sensor
|
|
---
|
|
|
|
[Apcupsd](http://www.apcupsd.org/) status information can be integrated into Home Assistant when the Network Information Server (NIS) [is configured](http://www.apcupsd.org/manual/manual.html#nis-server-client-configuration-using-the-net-driver) on the APC device.
|
|
|
|
There is currently support for the following device types within Home Assistant:
|
|
|
|
- [Binary Sensor](#binary-sensor)
|
|
- [Sensor](#sensor)
|
|
|
|
## Home Assistant add-on installation
|
|
|
|
Install this [unofficial add-on](https://github.com/korylprince/hassio-apcupsd/) to use this integration with Home Assistant. Keep in mind that we can't give you support for this add-on.
|
|
|
|
After installation, follow the instructions on the GitHub page to configure the plugin. Then continue to follow the integration configurations below.
|
|
|
|
## Configuration
|
|
|
|
To enable this sensor, add the following lines to your `configuration.yaml`:
|
|
|
|
```yaml
|
|
# Example configuration.yaml entry
|
|
apcupsd:
|
|
```
|
|
|
|
{% configuration %}
|
|
host:
|
|
description: The hostname/IP address on which the apcupsd NIS is being served.
|
|
required: false
|
|
type: string
|
|
default: localhost
|
|
port:
|
|
description: The port on which the apcupsd NIS is listening.
|
|
required: false
|
|
type: integer
|
|
default: 3551
|
|
{% endconfiguration %}
|
|
|
|
<div class='note'>
|
|
|
|
If you get `ConnectionRefusedError: Connection refused` errors in the Home Assistant logs, ensure the [Apcupsd](http://www.apcupsd.org/) configuration directives used by its Network Information Server is set to permit connections from all addresses [NISIP 0.0.0.0](http://www.apcupsd.org/manual/manual.html#configuration-directives-used-by-the-network-information-server), else non-local addresses will not connect.
|
|
|
|
</div>
|
|
|
|
## Binary sensor
|
|
|
|
In addition to the [Apcupsd Sensor](#sensor) devices, you may also create a device which is simply "on" when the UPS status is online and "off" at all other times.
|
|
|
|
### Configuration
|
|
|
|
To enable this sensor, you first have to set up apcupsd integration (above), and add the following lines to your `configuration.yaml` file:
|
|
|
|
```yaml
|
|
# Example configuration.yaml entry
|
|
binary_sensor:
|
|
- platform: apcupsd
|
|
```
|
|
|
|
{% configuration %}
|
|
name:
|
|
description: Name to use in the frontend.
|
|
required: false
|
|
type: string
|
|
default: UPS Online Status
|
|
{% endconfiguration %}
|
|
|
|
## Sensor
|
|
|
|
The `apcupsd` sensor platform allows you to monitor a UPS (battery backup) by using data from the [apcaccess](https://linux.die.net/man/8/apcaccess) command.
|
|
|
|
### Configuration
|
|
|
|
To use this sensor platform, you first have to set up apcupsd integration (above), and add the following to your `configuration.yaml` file:
|
|
|
|
```yaml
|
|
# Example configuration.yaml entry
|
|
sensor:
|
|
- platform: apcupsd
|
|
resources:
|
|
- bcharge
|
|
- linev
|
|
```
|
|
|
|
{% configuration %}
|
|
resources:
|
|
description: Contains all entries to display.
|
|
required: true
|
|
type: list
|
|
{% endconfiguration %}
|
|
|
|
### Example
|
|
|
|
Given the following output from `apcaccess`:
|
|
|
|
```yaml
|
|
APC : 001,051,1149
|
|
DATE : 2016-02-09 17:13:31 +0000
|
|
HOSTNAME : localhost
|
|
VERSION : 3.14.12 (29 March 2014) redhat
|
|
UPSNAME : netrack
|
|
CABLE : Custom Cable Smart
|
|
DRIVER : APC Smart UPS (any)
|
|
UPSMODE : Stand Alone
|
|
STARTTIME: 2016-02-09 16:06:47 +0000
|
|
MODEL : SMART-UPS 1400
|
|
STATUS : TRIM ONLINE
|
|
LINEV : 247.0 Volts
|
|
LOADPCT : 13.0 Percent
|
|
BCHARGE : 100.0 Percent
|
|
TIMELEFT : 104.0 Minutes
|
|
MBATTCHG : 5 Percent
|
|
MINTIMEL : 3 Minutes
|
|
MAXTIME : 0 Seconds
|
|
MAXLINEV : 249.6 Volts
|
|
MINLINEV : 244.4 Volts
|
|
OUTPUTV : 218.4 Volts
|
|
[...]
|
|
```
|
|
|
|
Use the values from the left hand column (lower case required).
|
|
|
|
Full Example Configuration:
|
|
|
|
```yaml
|
|
sensor:
|
|
- platform: apcupsd
|
|
resources:
|
|
- apc
|
|
- date
|
|
- hostname
|
|
- version
|
|
- upsname
|
|
- cable
|
|
- driver
|
|
- upsmode
|
|
- starttime
|
|
- model
|
|
- status
|
|
- linev
|
|
- loadpct
|
|
- bcharge
|
|
- timeleft
|
|
- mbattchg
|
|
- mintimel
|
|
- maxtime
|
|
- maxlinev
|
|
- minlinev
|
|
- outputv
|
|
```
|