KNX Climate | Instructions on how to integrate KNX thermostats with Home Assistant. |
|
0.25 | Local Push | knx |
The knx
integration must be configured correctly to use this integration, see KNX Integration.
The knx
climate platform is used as an interface to KNX thermostats and room controllers.
To use your KNX thermostats in your installation, add the following lines to your configuration.yaml
file:
# Example configuration.yaml entry
climate:
- platform: knx
name: HASS-Kitchen.Temperature
temperature_address: '5/1/1'
setpoint_shift_address: '5/1/2'
setpoint_shift_state_address: '5/1/3'
target_temperature_state_address: '5/1/4'
operation_mode_address: '5/1/5'
operation_mode_state_address: '5/1/6'
Alternatively, if your device has dedicated binary group addresses for frost/night/comfort mode:
# Example configuration.yaml entry
climate:
- platform: knx
name: HASS-Kitchen.Temperature
temperature_address: '5/1/1'
setpoint_shift_address: '5/1/2'
setpoint_shift_state_address: '5/1/3'
target_temperature_state_address: '5/1/4'
operation_mode_frost_protection_address: '5/1/5'
operation_mode_night_address: '5/1/6'
operation_mode_comfort_address: '5/1/7'
operation_mode_state_address: '5/1/8'
If your device doesn't support setpoint_shift calculations (i.e., if you don't provide a setpoint_shift_address
value) please set the min_temp
and max_temp
attributes of the climate device to avoid issues with exceeding valid temperature values in the frontend. Please do also make sure to add the target_temperature_address
to the configuration in this case.:
# Example configuration.yaml entry
climate:
- platform: knx
name: HASS-Kitchen.Temperature
temperature_address: '5/1/2'
target_temperature_address: '5/1/4'
target_temperature_state_address: '5/1/1'
operation_mode_frost_protection_address: '5/1/5'
operation_mode_night_address: '5/1/6'
operation_mode_comfort_address: '5/1/7'
operation_mode_state_address: '5/1/8'
min_temp: 7.0
max_temp: 32.0
operation_mode_frost_protection_address
/ operation_mode_night_address
/ operation_mode_comfort_address
are not necessary if operation_mode_address
is specified.
If the actor doesn't support explicit state communication objects the *_state_address can be configured with the same group address as the writeable *_address. The Read-Flag for the *_state_address communication object has to be set in ETS to support initial reading e.g., when starting Home Assistant.
The following values are valid for the hvac_mode
attribute:
- Off (maps internally to HVAC_MODE_OFF within Home Assistant)
- Auto (maps internally to HVAC_MODE_AUTO within Home Assistant)
- Heat (maps internally to HVAC_MDOE_HEAT within Home Assistant)
- Cool (maps internally to HVAC_MDOE_COOL within Home Assistant)
- Fan only (maps internally to HVAC_MODE_FAN_ONLY within Home Assistant)
- Dry (maps internally to HVAC_MODE_DRY within Home Assistant)
The following presets are valid for the preset_mode
attribute:
- Comfort (maps internally to PRESET_COMFORT within Home Assistant)
- Standby (maps internally to PRESET_AWAY within Home Assistant)
- Night (maps internally to PRESET_SLEEP within Home Assistant)
- Frost Protection (maps internally to PRESET_ECO within Home Assistant)
{% configuration %} name: description: A name for this device used within Home Assistant. required: false default: KNX Climate type: string temperature_address: description: KNX group address for reading current room temperature from KNX bus. DPT 9.001 required: true type: string target_temperature_address: description: KNX group address for setting target temperature. DPT 9.001 required: false type: string target_temperature_state_address: description: KNX group address for reading current target temperature from KNX bus. DPT 9.001 required: true type: string setpoint_shift_address: description: KNX address for setpoint_shift. DPT 6.010 required: false type: string setpoint_shift_state_address: description: KNX address for reading setpoint_shift. DPT 6.010 required: false type: string setpoint_shift_step: description: Defines the step size in Kelvin for each step of setpoint_shift. required: false default: 0.5 type: float setpoint_shift_min: description: Minimum value of setpoint shift. required: false default: -6 type: float setpoint_shift_max: description: Maximum value of setpoint shift. required: false default: 6 type: float operation_mode_address: description: KNX address for setting operation mode (Frost protection/night/comfort). DPT 20.102 required: false type: string operation_mode_state_address: description: KNX address for reading operation mode. DPT 20.102 required: false type: string controller_status_address: description: KNX address for HVAC controller status (in accordance with KNX AN 097/07 rev 3). required: false type: string controller_status_state_address: description: KNX address for reading HVAC controller status. required: false type: string controller_mode_address: description: KNX address for setting HVAC controller modes. DPT 20.105 required: false type: string controller_mode_state_address: description: KNX address for reading HVAC Control Mode. DPT 20.105 required: false type: string operation_mode_frost_protection_address: description: KNX address for switching on/off frost/heat protection mode. required: false type: string operation_mode_night_address: description: KNX address for switching on/off night mode. required: false type: string operation_mode_comfort_address: description: KNX address for switching on/off comfort mode. required: false type: string operation_modes: description: Overrides the supported operation modes. required: false type: list on_off_address: description: KNX address for switching the climate device on/off. required: false type: string on_off_invert: description: Value for switching the climate device on/off is inverted. required: false default: false type: boolean on_off_state_address: description: KNX address for gathering the current state (on/off) of the climate device. required: false type: string min_temp: description: Override the minimum temperature. required: false type: float max_temp: description: Override the maximum temperature. required: false type: float {% endconfiguration %}