title, description, ha_category, ha_release, ha_codeowners, ha_domain
title | description | ha_category | ha_release | ha_codeowners | ha_domain | |||
---|---|---|---|---|---|---|---|---|
Honeywell Total Connect Alarm | Instructions on how to integrate TotalConnect alarms into Home Assistant. |
|
0.42 |
|
totalconnect |
The totalconnect
integration provides connectivity with the Honeywell TotalConnect alarm systems used by many alarm companies.
If you have issues running this component, you may require libxml2-dev
and libxmlsec1-dev
packages. To install these on Raspbian, run the command apt install libxml2-dev libxmlsec1-dev
with sudo.
Alarm Control Panel
The integration provides an Alarm Control Panel for each TotalConnect location. It uses the name of your location from TotalConnect. For example, if your location name in TotalConnect is "Home", then you will get alarm_control_panel.home
in Home Assistant.
The alarm control panel supports the following services: alarm_arm_away
, alarm_arm_home
, alarm_arm_night
and alarm_disarm
.
The triggered
state also provides a state attribute called triggered_source
giving more detail on what triggered the alarm:
Police/Medical
is when sensors detected a burglar and/or a person pushed the Police or Medical buttonFire/Smoke
is when fire or smoke is detected, or a person pushed the Fire buttonCarbon Monoxide
is when carbon monoxide is detected
Binary Sensor
The integration provides a Binary Sensor for each TotalConnect zone. To see zones in TotalConnect "fault" status, your TotalConnect account must have "Sensor Events" enabled. Your alarm monitoring company may charge an extra fee to enable this.
The TotalConnect API has limited zone type information. Home Assistant device class door
is assigned to TotalConnect door, window, perimeter, motion sensor, and most alarm panel buttons. The sensor will appear as True
if the door is open (either fault or triggered in TotalConnect) and False
otherwise. Device class smoke
is assigned to TotalConnect smoke detectors and buttons with physical alarm panel "Response Type" setting of "Fire No Verification". The sensor will appear as True
if smoke is detected. Device class gas
is assigned to TotalConnect carbon monoxide detectors. The sensor will appear as True
if gas is detected.
Configuration
To enable TotalConnect, add the following lines to your configuration.yaml
:
totalconnect:
username: YOUR_USERNAME
password: YOUR_PASSWORD
{% configuration %} name: description: Name of device in Home Assistant. required: false type: string username: description: Username used to sign into the TotalConnect app/web client. required: true type: string password: description: Password used to sign into the TotalConnect app/web client. required: true type: string {% endconfiguration %}
You are highly encouraged to create a Total Connect user account specifically for Home Assistant. It should not have full administrative privileges.
Automation example
automation:
- alias: "Alarm: Disarmed Daytime"
trigger:
platform: state
entity_id: alarm_control_panel.total_connect
to: 'disarmed'
condition:
condition: sun
before: sunset
action:
service: scene.turn_on
entity_id: scene.OnDisarmedDaytime
- alias: "Alarm: Armed Away"
trigger:
platform: state
entity_id: alarm_control_panel.total_connect
to: 'armed_away'
action:
service: scene.turn_on
entity_id: scene.OnArmedAway