title: KNX
|
|
description: Instructions on how to integrate KNX components with Home Assistant.
|
|
featured: true
|
|
ha_category:
|
|
- Binary sensor
|
|
- Button
|
|
- Climate
|
|
- Cover
|
|
- Date
|
|
- Fan
|
|
- Hub
|
|
- Light
|
|
- Notifications
|
|
- Number
|
|
- Scene
|
|
- Select
|
|
- Sensor
|
|
- Switch
|
|
- Text
|
|
- Time
|
|
- Weather
|
|
ha_release: 0.24
|
|
ha_iot_class: Local Push
|
|
ha_codeowners:
|
|
- '@Julius2342'
|
|
- '@farmio'
|
|
- '@marvin-w'
|
|
ha_domain: knx
|
|
ha_quality_scale: platinum
|
|
ha_platforms:
|
|
- binary_sensor
|
|
- button
|
|
- climate
|
|
- cover
|
|
- date
|
|
- diagnostics
|
|
- fan
|
|
- light
|
|
- notify
|
|
- number
|
|
- scene
|
|
- select
|
|
- sensor
|
|
- switch
|
|
- text
|
|
- time
|
|
- weather
|
|
ha_config_flow: true
|
|
ha_integration_type: hub
|
|
---
|
|
|
|
The [KNX](https://www.knx.org) integration for Home Assistant allows you to connect to KNX/IP devices.
|
|
|
|
The integration requires a local KNX/IP interface or router. Through this, it will establish a connection between Home Assistant and your KNX bus.
|
|
|
|
There is currently support for the following device types within Home Assistant:
|
|
|
|
- [Binary sensor](#binary-sensor)
|
|
- [Button](#button)
|
|
- [Climate](#climate)
|
|
- [Cover](#cover)
|
|
- [Date](#date)
|
|
- [Fan](#fan)
|
|
- [Light](#light)
|
|
- [Notify](#notify)
|
|
- [Number](#number)
|
|
- [Scene](#scene)
|
|
- [Select](#select)
|
|
- [Sensor](#sensor)
|
|
- [Switch](#switch)
|
|
- [Text](#text)
|
|
- [Time](#time)
|
|
- [Weather](#weather)
|
|
|
|
## Free KNX online training
|
|
|
|
As a Home Assistant KNX user, you can start a FREE KNX online training and get a discounted ETS Home license on the [KNX website](https://www.knx.org/knx-en/for-your-home/home-assistant/).
|
|
|
|
{% include integrations/config_flow.md %}
|
|
|
|
## Basic configuration
|
|
|
|
In order to make use of the various platforms that KNX offers you will need to add the relevant configuration sections to your setup. This could either all be in the Home Assistant main `configuration.yaml` file, or in a separate YAML file that you include in the main file or even be split into multiple dedicated files. See [Splitting up the configuration](/docs/configuration/splitting_configuration/).
|
|
|
|
```yaml
|
|
knx:
|
|
# configure platforms directly in configuration.yaml
|
|
binary_sensor:
|
|
- name: "My first binary sensor"
|
|
state_address: "1/2/3"
|
|
# etc...
|
|
# or outsource platform configuration to separate files
|
|
sensor: !include knx_sensor.yaml
|
|
```
|
|
|
|
Please see the dedicated platform sections below about how to configure them correctly.
|
|
|
|
### Group addresses
|
|
|
|
Group addresses are configured as strings or integers in the format "1/2/3" for 3-level GA-structure, "1/2" for 2-level GA-structure or "1" for free GA-structure.
|
|
|
|
The HA KNX integration uses configured `state_address` or `*_state_address` to update the state of a function. These addresses are read by GroupValueRead requests on startup and when there was no incoming telegram for one hour (default `sync_state`).
|
|
|
|
It is possible to configure passive/listening group addresses for all functions of every KNX platform (except `expose` and `notify`). This allows having multiple group addresses to update the state of its function (e.g., the brightness of a light). When group addresses are configured as a list of strings, the first item is the active sending or state-reading address and the rest is registered as passive addresses. This schema behaves like in ETS configuration where the first is the "sending" address and others are just for updating the group object.
|
|
|
|
If your KNX device provides active state group objects it is advised to use `*_state_address` instead of passive addresses as it reduces configuration complexity and avoids wrong states (e.g., when channels are logically locked).
|
|
|
|
```yaml
|
|
knx:
|
|
switch:
|
|
- name: "Switch without passive addresses"
|
|
address: "1/1/1" # this is the address that will be sent to
|
|
state_address: "8/8/8" # this is the address GroupValueRead requests are sent to
|
|
- name: "Switch with passive addresses"
|
|
address:
|
|
- "1/1/1" # this is the address that will be sent to
|
|
- "1/1/2" # this and following are passive addresses
|
|
- "1/1/3"
|
|
state_address:
|
|
- "8/8/8" # this is the address GroupValueRead requests are sent to
|
|
- "8/8/2" # this and following are passive addresses
|
|
- "8/8/3"
|
|
```
|
|
|
|
## Connection
|
|
|
|
Connection parameters are set up when adding the integration and can be changed from the `Integrations` panel.
|
|
|
|
Use `route back` if your tunneling server is located on a different network.
|
|
|
|
### KNX Secure
|
|
|
|
The KNX integration supports IP Secure and Data Secure .
|
|
|
|
You can configure the IP Secure credentials either manually or by providing a `.knxkeys` file, which you can obtain by exporting the keyring in ETS as seen in the screenshot below.
|
|
Data Secure credentials are always sourced from a `.knxkeys` file. You can import or update the Keyring file from the integrations settings.
|
|
|
|
For Data Secure, please make sure that all secured group addresses you want to use in Home Assistant are assigned to a tunnel of your interface or a dummy device in ETS and all participating devices are updated accordingly.
|
|
|
|

|
|
|
|
If you decide to configure IP Secure manually you will need the user ID, the user password and the device authentication password.
|
|
|
|
The user id 0 is reserved and the user id 1 is used for management tasks, thus you will need to specify a user id that is 2 or higher according to the tunneling channel you would like to use.
|
|
|
|
The following screenshot will show how you can get the device authentication password in ETS.
|
|
|
|

|
|
|
|
The user password can be obtained almost the same way as seen in the below screenshot.
|
|
|
|

|
|
|
|
## Events
|
|
|
|
```yaml
|
|
knx:
|
|
event:
|
|
- address:
|
|
- "0/1/*"
|
|
- address:
|
|
- "1/2/*"
|
|
- "1/3/2-4"
|
|
type: "2byte_unsigned"
|
|
- address:
|
|
- "3/4/5"
|
|
type: "2byte_float"
|
|
```
|
|
|
|
{% configuration %}
|
|
address:
|
|
description: Defines a list of patterns for matching KNX group addresses. Telegrams with destination addresses matching one of the patterns are sent to the Home Assistant event bus as `knx_event`.
|
|
required: true
|
|
type: [list, string]
|
|
type:
|
|
description: Telegram payloads in `knx_event` events will be decoded using the configured type (DPT) for the addresses in the same block. The decoded value will be written to the event data `value` key. If not configured the `value` key will be `None` - the `data` key will still hold the raw payload (use this for DPT 1, 2, 3). All sensor types are valid types - see [KNX Sensor](#sensor) (e.g., "2byte_float" or "1byte_signed").
|
|
type: [string, integer]
|
|
required: false
|
|
{% endconfiguration %}
|
|
|
|
Every telegram that matches an address pattern with its destination field will be announced on the event bus as a `knx_event` event containing data attributes
|
|
|
|
- `data` contains the raw payload data (e.g., 1 or "[12, 55]").
|
|
- `destination` the KNX group address the telegram is sent to as string (e.g., "1/2/3").
|
|
- `direction` the direction of the telegram as string ("Incoming" / "Outgoing").
|
|
- `source` the KNX individual address of the sender as string (e.g., "1.2.3").
|
|
- `telegramtype` the APCI service of the telegram. "GroupValueWrite", "GroupValueRead" or "GroupValueResponse" generate a knx_event.
|
|
- `value` contains the decoded payload value if `type` is configured for the address. Will be `None` for "GroupValueRead" telegrams.
|
|
|
|
## Services
|
|
|
|
In order to directly interact with the KNX bus, you can use the following services:
|
|
|
|
### Send
|
|
|
|
```txt
|
|
Domain: knx
|
|
Service: send
|
|
Service Data: {"address": "1/0/15", "payload": 0, "type": "temperature"}
|
|
```
|
|
|
|
{% configuration %}
|
|
address:
|
|
description: KNX group address.
|
|
type: string
|
|
payload:
|
|
description: Payload to send to the bus. When `type` is not set, raw bytes are sent. Integers are then treated as DPT 1/2/3 payloads. For DPTs > 6 bits send a list. Each value represents 1 octet (0-255). Pad with 0 to DPT byte length.
|
|
type: [integer, list]
|
|
type:
|
|
description: If set, the payload will not be sent as raw bytes, but encoded as given DPT. KNX sensor types are valid values - see table in [KNX Sensor](#sensor).
|
|
type: [string, integer, float]
|
|
response:
|
|
description: If set to `true`, the telegram will be sent as a `GroupValueResponse` instead of a `GroupValueWrite`.
|
|
type: boolean
|
|
default: false
|
|
{% endconfiguration %}
|
|
|
|
### Read
|
|
|
|
You can use the `homeassistant.update_entity` service call to issue GroupValueRead requests for all `*state_address` of an entity.
|
|
To manually send GroupValueRead requests use the `knx.read` service. The response can be used from `knx_event` and will be processed in KNX entities.
|
|
|
|
```txt
|
|
Domain: knx
|
|
Service: read
|
|
Service Data: {"address": "1/0/15"}
|
|
```
|
|
|
|
{% configuration %}
|
|
address:
|
|
description: Group address(es) to send read request to. Lists will read multiple group addresses.
|
|
type: [string, list]
|
|
{% endconfiguration %}
|
|
|
|
```yaml
|
|
# Example automation to update a cover position after 10 seconds of movement initiation
|
|
automation:
|
|
- trigger:
|
|
- platform: event
|
|
event_type: knx_event
|
|
event_data:
|
|
# Cover move trigger
|
|
destination: "0/4/20"
|
|
action:
|
|
- delay: 0:0:10
|
|
- service: knx.read
|
|
data:
|
|
# Cover position address
|
|
address: "0/4/21"
|
|
|
|
- trigger:
|
|
- platform: homeassistant
|
|
event: start
|
|
action:
|
|
# Register the group address to trigger a knx_event
|
|
- service: knx.event_register
|
|
data:
|
|
# Cover move trigger
|
|
address: "0/4/20"
|
|
- service: knx.read
|
|
data:
|
|
# Cover position address
|
|
address: "0/4/21"
|
|
```
|
|
|
|
### Register event
|
|
|
|
The `knx.event_register` service can be used to register (or unregister) group addresses to fire `knx_event` Events. Events for group addresses configured in the `event` key in `configuration.yaml` cannot be unregistered. See [knx_event](#events)
|
|
|
|
{% configuration %}
|
|
address:
|
|
description: Group address that shall be added or removed.
|
|
required: true
|
|
type: [string, list]
|
|
remove:
|
|
description: If `True` the group address will be removed.
|
|
required: false
|
|
type: boolean
|
|
default: false
|
|
type:
|
|
description: If set, the payload will be decoded as given DPT in the event data `value` key. KNX sensor types are valid values [KNX Sensor](#sensor) (e.g., "2byte_float" or "1byte_signed").
|
|
type: [string, integer]
|
|
required: false
|
|
{% endconfiguration %}
|
|
|
|
### Register exposure
|
|
|
|
The `knx.exposure_register` service can be used to register (or unregister) exposures to the KNX bus. Exposures defined in `configuration.yaml` can not be unregistered. Per address only one exposure can be registered. See [expose](#exposing-entity-states-entity-attributes-or-time-to-knx-bus)
|
|
|
|
{% configuration %}
|
|
remove:
|
|
description: In addition to the configuration variables of [expose](#exposing-entity-states-entity-attributes-or-time-to-knx-bus) `remove` set to `True` can be used to remove exposures. Only `address` is required for removal.
|
|
required: false
|
|
type: boolean
|
|
default: false
|
|
{% endconfiguration %}
|
|
|
|
## Exposing entity states, entity attributes or time to KNX bus
|
|
|
|
KNX integration is able to expose entity states or attributes to KNX bus. The integration will broadcast any change of the exposed value to the KNX bus and answer read requests to the specified group address.
|
|
It is also possible to expose the current time and date. These are sent to the bus every hour.
|
|
|
|
<div class='note'>
|
|
|
|
Expose is only triggered on state changes. If you need periodical telegrams, use an automation with the `knx.send` service to send the value to the bus.
|
|
|
|
</div>
|
|
|
|
```yaml
|
|
# Example configuration.yaml entry
|
|
knx:
|
|
expose:
|
|
- type: temperature
|
|
entity_id: sensor.owm_temperature
|
|
address: "0/0/2"
|
|
cooldown: 600
|
|
- type: string
|
|
address: "0/6/4"
|
|
entity_id: sensor.owm_weather
|
|
- type: binary
|
|
entity_id: binary_sensor.kitchen_window
|
|
address: "0/6/5"
|
|
- type: binary
|
|
entity_id: light.office
|
|
address: "0/3/0"
|
|
default: false
|
|
- type: percentU8
|
|
entity_id: light.office
|
|
attribute: brightness
|
|
default: 0
|
|
address: "0/3/1"
|
|
- type: time
|
|
address: "0/0/1"
|
|
- type: datetime
|
|
address: "0/0/23"
|
|
```
|
|
|
|
{% configuration %}
|
|
address:
|
|
description: Group address state or attribute updates will be sent to. GroupValueRead requests will be answered.
|
|
type: string
|
|
required: true
|
|
type:
|
|
description: Type of the exposed value. Either `binary`, `time` *DPT 10.001*, `date` *DPT 11.001*, `datetime` *DPT 19.001* or any supported type of [KNX Sensor](#sensor) (e.g., "temperature" or "humidity").
|
|
type: [string, integer]
|
|
required: true
|
|
entity_id:
|
|
description: Entity ID to be exposed. Not needed for types `time`, `date` and `datetime`.
|
|
type: string
|
|
required: false
|
|
attribute:
|
|
description: Attribute of the entity that shall be sent to the KNX bus. If not set (or `None`) the state will be sent.
|
|
For example for a light the state is either "on" or "off". With `attribute` you can expose its "brightness".
|
|
type: string
|
|
required: false
|
|
default:
|
|
description: Default value to send to the bus if the state or attribute value is `None`.
|
|
For example a light with state "off" has no brightness attribute so a default value of `0` could be used.
|
|
If not set (or `None`) no value would be sent to the bus and a GroupReadRequest to the address would return the last known value.
|
|
type: [boolean, string, integer, float]
|
|
default: None
|
|
required: false
|
|
cooldown:
|
|
description: Minimum time in seconds between two sent telegrams. This can be used to avoid flooding the KNX bus when exposing frequently changing states. If the state changes multiple times within the cooldown period the most recent value will be sent.
|
|
type: float
|
|
default: 0
|
|
required: false
|
|
respond_to_read:
|
|
description: Respond to GroupValueRead telegrams received to the configured `address`.
|
|
required: false
|
|
type: boolean
|
|
default: true
|
|
{% endconfiguration %}
|
|
|
|
## Binary sensor
|
|
|
|
The KNX binary sensor platform allows you to monitor [KNX](https://www.knx.org/) binary sensors.
|
|
|
|
Binary sensors are read-only. To write to the KNX bus configure an exposure [KNX Integration Expose](/integrations/knx/#exposing-entity-states-entity-attributes-or-time-to-knx-bus).
|
|
|
|
```yaml
|
|
knx:
|
|
binary_sensor:
|
|
- name: "Sensor 1"
|
|
state_address: "6/0/2"
|
|
```
|
|
|
|
{% configuration %}
|
|
state_address:
|
|
description: KNX group address of the binary sensor. *DPT 1*
|
|
required: true
|
|
type: [string, list]
|
|
name:
|
|
description: A name for this device used within Home Assistant.
|
|
required: false
|
|
type: string
|
|
sync_state:
|
|
description: Actively read the value from the bus. The maximum time interval (`<minutes>`) is 1440. The following values are valid
|
|
|
|
- `true` equivalent to "expire 60" (default)
|
|
|
|
- `false` no GroupValueRead telegrams will be sent to the bus
|
|
|
|
- `every <minutes>` to update it regularly every \<minutes\>
|
|
|
|
- `expire <minutes>` to read the state from the KNX bus when no telegram was received for \<minutes\>
|
|
|
|
- `<minutes>` equivalent to "expire \<minutes\>"
|
|
|
|
- `init` to just initialize the state on startup
|
|
|
|
required: false
|
|
type: [boolean, string, integer]
|
|
default: true
|
|
device_class:
|
|
description: Sets the [class of the device](/integrations/binary_sensor/), changing the device state and icon that is displayed on the frontend.
|
|
required: false
|
|
type: string
|
|
reset_after:
|
|
description: Reset back to "off" state after specified seconds.
|
|
required: false
|
|
type: float
|
|
invert:
|
|
description: Invert the telegrams payload before processing. This is applied before `context_timeout` or `reset_after` is evaluated.
|
|
required: false
|
|
type: boolean
|
|
default: false
|
|
ignore_internal_state:
|
|
description: Specifies if telegrams should ignore the internal state and always trigger a Home Assistant state update.
|
|
required: false
|
|
type: boolean
|
|
default: false
|
|
context_timeout:
|
|
description: The time in seconds between multiple identical telegram payloads would count towards the internal counter that is used for automations. Ex. You have automations in place that trigger your lights on button press and another set of lights if you click that button twice. This setting defines the time that a second button press would count toward, so if you set this 3.0 you can take up to 3 seconds in order to trigger the second button press. If set `ignore_internal_state` will be set to `true` internally. Maximum value is 10.0.
|
|
required: false
|
|
type: float
|
|
default: None
|
|
entity_category:
|
|
description: The [category](https://developers.home-assistant.io/docs/core/entity#generic-properties) of the entity.
|
|
required: false
|
|
type: string
|
|
default: None
|
|
{% endconfiguration %}
|
|
|
|
### Support for automations
|
|
|
|
You can use a built in event in order to trigger an automation (e.g. to switch on a light when a switch was pressed).
|
|
|
|
Let's pretend you have a binary sensor with the name `Livingroom.Switch` and you want to switch one light on when the button was pressed once and two other lights when the button was pressed twice. `context_timeout` has to be configured in order for this to work.
|
|
|
|
```yaml
|
|
# Example automation.yaml entry
|
|
automation:
|
|
- trigger:
|
|
platform: numeric_state
|
|
entity_id: binary_sensor.livingroom_switch
|
|
attribute: counter
|
|
above: 0
|
|
below: 2
|
|
condition:
|
|
- condition: state
|
|
entity_id: binary_sensor.cover_abstell
|
|
state: "on"
|
|
action:
|
|
- entity_id: light.hue_color_lamp_1
|
|
service: light.turn_on
|
|
- trigger:
|
|
platform: numeric_state
|
|
entity_id: binary_sensor.livingroom_switch
|
|
attribute: counter
|
|
above: 1
|
|
below: 3
|
|
condition:
|
|
- condition: state
|
|
entity_id: binary_sensor.cover_abstell
|
|
state: "on"
|
|
action:
|
|
- entity_id: light.hue_bloom_1
|
|
service: homeassistant.turn_on
|
|
- entity_id: light.hue_bloom_2
|
|
service: homeassistant.turn_on
|
|
```
|
|
|
|
{% configuration %}
|
|
name:
|
|
description: A name for this device used within Home Assistant.
|
|
required: false
|
|
type: string
|
|
counter:
|
|
description: Set to 2 if you only want the action to be executed if the button was pressed twice. Set to 3 for three times button pressed.
|
|
required: false
|
|
type: integer
|
|
default: 1
|
|
hook:
|
|
description: Indicates if the automation should be executed on what state of the binary sensor. Values are "on" or "off".
|
|
required: false
|
|
type: string
|
|
default: "on"
|
|
action:
|
|
description: Specify a list of actions analog to the [automation rules](/docs/automation/action/).
|
|
required: false
|
|
type: list
|
|
{% endconfiguration %}
|
|
|
|
## Button
|
|
|
|
The KNX button platform allows to send concurrent predefined values via the frontend or a platform service. When a user presses the button, the assigned generic raw payload is sent to the KNX bus.
|
|
|
|
<div class='note'>
|
|
|
|
Telegrams received on the KNX bus for the group address of a button are not reflected in a new button state. Use `knx_event` if you want to automate on a specific payload received on a group address.
|
|
|
|
</div>
|
|
|
|
```yaml
|
|
# Example configuration.yaml entry
|
|
knx:
|
|
button:
|
|
- name: "DPT 1 - True button"
|
|
address: "0/0/1"
|
|
- name: "100% button"
|
|
address: "0/0/2"
|
|
payload: 0xFF
|
|
payload_length: 1
|
|
- name: "Temperature button"
|
|
address: "0/0/3"
|
|
value: 21.5
|
|
type: temperature
|
|
```
|
|
|
|
<div class='note'>
|
|
|
|
When `type` is used `value` is required, `payload` is invalid.
|
|
When `payload_length` is used `value` is invalid.
|
|
|
|
</div>
|
|
|
|
{% configuration %}
|
|
name:
|
|
description: A name for this device used within Home Assistant.
|
|
required: false
|
|
type: string
|
|
address:
|
|
description: Group address to send to.
|
|
required: true
|
|
type: string
|
|
payload:
|
|
description: The raw payload that shall be sent.
|
|
required: false
|
|
type: integer
|
|
default: 1
|
|
payload_length:
|
|
description: The length of the payload data in the telegram. Use `0` for DPT 1, 2 or 3.
|
|
required: false
|
|
type: integer
|
|
default: 0
|
|
value:
|
|
description: The value that shall be sent encoded by `type`.
|
|
required: false
|
|
type: [integer, float, string]
|
|
type:
|
|
description: A type from the [value types table](/integrations/knx/#value-types) to encode the configured `value`.
|
|
required: false
|
|
type: [string, integer]
|
|
entity_category:
|
|
description: The [category](https://developers.home-assistant.io/docs/core/entity#generic-properties) of the entity.
|
|
required: false
|
|
type: string
|
|
default: None
|
|
{% endconfiguration %}
|
|
|
|
## Climate
|
|
|
|
The KNX climate platform is used as an interface to KNX thermostats and room controllers.
|
|
|
|
To use your KNX thermostats in your installation, add the following lines to your top level [KNX Integration](/integrations/knx) configuration key in `configuration.yaml`:
|
|
|
|
```yaml
|
|
# Example configuration.yaml entry
|
|
knx:
|
|
climate:
|
|
- name: "Kitchen"
|
|
temperature_address: "5/1/1"
|
|
setpoint_shift_address: "5/1/2"
|
|
setpoint_shift_state_address: "5/1/3"
|
|
target_temperature_state_address: "5/1/4"
|
|
operation_mode_address: "5/1/5"
|
|
operation_mode_state_address: "5/1/6"
|
|
```
|
|
|
|
Alternatively, if your device has dedicated binary group addresses for frost/night/comfort mode:
|
|
|
|
```yaml
|
|
# Example configuration.yaml entry
|
|
knx:
|
|
climate:
|
|
- name: "Kitchen"
|
|
temperature_address: "5/1/1"
|
|
setpoint_shift_address: "5/1/2"
|
|
setpoint_shift_state_address: "5/1/3"
|
|
target_temperature_state_address: "5/1/4"
|
|
operation_mode_frost_protection_address: "5/1/5"
|
|
operation_mode_night_address: "5/1/6"
|
|
operation_mode_comfort_address: "5/1/7"
|
|
operation_mode_state_address: "5/1/8"
|
|
```
|
|
|
|
If your device doesn't support setpoint_shift calculations (i.e., if you don't provide a `setpoint_shift_address` value) please set the `min_temp` and `max_temp`
|
|
attributes of the climate device to avoid issues with exceeding valid temperature values in the frontend. Please do also make sure to add the `target_temperature_address` to the configuration in this case.:
|
|
|
|
```yaml
|
|
# Example configuration.yaml entry
|
|
knx:
|
|
climate:
|
|
- name: "Kitchen"
|
|
temperature_address: "5/1/2"
|
|
target_temperature_address: "5/1/4"
|
|
target_temperature_state_address: "5/1/1"
|
|
operation_mode_frost_protection_address: "5/1/5"
|
|
operation_mode_night_address: "5/1/6"
|
|
operation_mode_comfort_address: "5/1/7"
|
|
operation_mode_state_address: "5/1/8"
|
|
operation_mode_standby_address: "5/1/9"
|
|
min_temp: 7.0
|
|
max_temp: 32.0
|
|
```
|
|
|
|
`setpoint_shift_mode` allows the two following DPTs to be used:
|
|
|
|
- DPT6010 (for 1 byte signed integer with scale factor)
|
|
- DPT9002 (for 2 byte float)
|
|
|
|
Example:
|
|
|
|
```yaml
|
|
# Example configuration.yaml entry
|
|
knx:
|
|
climate:
|
|
- name: "Kitchen"
|
|
temperature_address: "5/1/1"
|
|
setpoint_shift_address: "5/1/2"
|
|
setpoint_shift_state_address: "5/1/3"
|
|
setpoint_shift_mode: "DPT9002"
|
|
target_temperature_state_address: "5/1/4"
|
|
operation_mode_address: "5/1/5"
|
|
operation_mode_state_address: "5/1/6"
|
|
```
|
|
|
|
`operation_mode_frost_protection_address` / `operation_mode_night_address` / `operation_mode_comfort_address` / `operation_mode_standby_address` are not necessary if `operation_mode_address` is specified.
|
|
If the actor doesn't support explicit state group objects the `*_state_address` can be configured with the same group address as the writeable `*_address`. The read flag for the `*_state_address` group object has to be set in ETS to support initial reading e.g., when starting Home Assistant.
|
|
|
|
The following values are valid for the `heat_cool_address` and the `heat_cool_state_address`:
|
|
|
|
- `0` (cooling)
|
|
- `1` (heating)
|
|
|
|
The following values are valid for the Home Assistant [Climate](/integrations/climate/) `hvac_mode` attribute. Supported values for your KNX thermostats can be specified via `controller_modes` configuration variable:
|
|
|
|
- `Off` (maps internally to `HVAC_MODE_OFF` within Home Assistant)
|
|
- `Auto` (maps internally to `HVAC_MODE_AUTO` within Home Assistant)
|
|
- `Heat` (maps internally to `HVAC_MODE_HEAT` within Home Assistant)
|
|
- `Cool` (maps internally to `HVAC_MODE_COOL` within Home Assistant)
|
|
- `Fan only` (maps internally to `HVAC_MODE_FAN_ONLY` within Home Assistant)
|
|
- `Dry` (maps internally to `HVAC_MODE_DRY` within Home Assistant)
|
|
|
|
The following presets are valid for the Home Assistant [Climate](/integrations/climate/) `preset_mode` attribute. Supported values for your KNX thermostats can be specified via `operation_modes` configuration variable:
|
|
|
|
- `Auto` (maps to `none` of the Home Assistant [Climate](/integrations/climate/) `preset_mode` attribute)
|
|
- `Comfort` (maps to `comfort` of the Home Assistant [Climate](/integrations/climate/) `preset_mode` attribute)
|
|
- `Standby` (maps to `away` of the Home Assistant [Climate](/integrations/climate/) `preset_mode` attribute)
|
|
- `Night` (maps to `sleep` of the Home Assistant [Climate](/integrations/climate/) `preset_mode` attribute)
|
|
- `Frost Protection` (maps to `eco` of the Home Assistant [Climate](/integrations/climate/) `preset_mode` attribute)
|
|
|
|
{% configuration %}
|
|
name:
|
|
description: A name for this device used within Home Assistant.
|
|
required: false
|
|
default: KNX Climate
|
|
type: string
|
|
temperature_address:
|
|
description: KNX group address for reading current room temperature from KNX bus. *DPT 9.001*
|
|
required: true
|
|
type: [string, list]
|
|
temperature_step:
|
|
description: Defines the step size in Kelvin for each step of setpoint_shift (scale factor). For non setpoint-shift configurations this is used to set the step of temperature sliders in UI.
|
|
required: false
|
|
type: float
|
|
default: 0.1
|
|
target_temperature_address:
|
|
description: KNX group address for setting target temperature. *DPT 9.001*
|
|
required: false
|
|
type: [string, list]
|
|
target_temperature_state_address:
|
|
description: KNX group address for reading current target temperature from KNX bus. *DPT 9.001*
|
|
required: true
|
|
type: [string, list]
|
|
setpoint_shift_address:
|
|
description: KNX address for setpoint_shift. *DPT 6.010 or DPT 9.002 based on setpoint_shift_mode*
|
|
required: false
|
|
type: [string, list]
|
|
setpoint_shift_state_address:
|
|
description: KNX address for reading setpoint_shift. *DPT 6.010 or DPT 9.002 based on setpoint_shift_mode*
|
|
required: false
|
|
type: [string, list]
|
|
setpoint_shift_mode:
|
|
description: Defines the internal device DPT used. Either 'DPT6010', 'DPT9002' or None. When `None` or omitted the DPT is auto-assigned from the first incoming telegram.
|
|
required: false
|
|
type: string
|
|
default: None
|
|
setpoint_shift_min:
|
|
description: Minimum value of setpoint shift.
|
|
required: false
|
|
default: -6
|
|
type: float
|
|
setpoint_shift_max:
|
|
description: Maximum value of setpoint shift.
|
|
required: false
|
|
default: 6
|
|
type: float
|
|
active_state_address:
|
|
description: KNX address for reading current activity. `0` is idle, `1` is active. *DPT 1*
|
|
required: false
|
|
type: [string, list]
|
|
command_value_state_address:
|
|
description: KNX address for reading current command value in percent. `0` sets the climate entity to idle if `active_state_address` is not set. *DPT 5.001*
|
|
required: false
|
|
type: [string, list]
|
|
operation_mode_address:
|
|
description: KNX address for setting operation mode (Frost protection/night/comfort). *DPT 20.102*
|
|
required: false
|
|
type: [string, list]
|
|
operation_mode_state_address:
|
|
description: KNX address for reading operation mode. *DPT 20.102*
|
|
required: false
|
|
type: [string, list]
|
|
controller_status_address:
|
|
description: KNX address for HVAC controller status (in accordance with KNX AN 097/07 rev 3).
|
|
required: false
|
|
type: [string, list]
|
|
controller_status_state_address:
|
|
description: KNX address for reading HVAC controller status.
|
|
required: false
|
|
type: [string, list]
|
|
controller_mode_address:
|
|
description: KNX address for setting HVAC controller modes. *DPT 20.105*
|
|
required: false
|
|
type: [string, list]
|
|
controller_mode_state_address:
|
|
description: KNX address for reading HVAC control mode. *DPT 20.105*
|
|
required: false
|
|
type: [string, list]
|
|
heat_cool_address:
|
|
description: KNX address for switching between heat/cool mode. *DPT 1.100*
|
|
required: false
|
|
type: [string, list]
|
|
heat_cool_state_address:
|
|
description: KNX address for reading heat/cool mode. *DPT 1.100*
|
|
required: false
|
|
type: [string, list]
|
|
operation_mode_frost_protection_address:
|
|
description: KNX address for switching on/off frost/heat protection mode. *DPT 1*
|
|
required: false
|
|
type: [string, list]
|
|
operation_mode_night_address:
|
|
description: KNX address for switching on/off night mode. *DPT 1*
|
|
required: false
|
|
type: [string, list]
|
|
operation_mode_comfort_address:
|
|
description: KNX address for switching on/off comfort mode. *DPT 1*
|
|
required: false
|
|
type: [string, list]
|
|
operation_mode_standby_address:
|
|
description: KNX address for switching on/off standby mode. *DPT 1*
|
|
required: false
|
|
type: [string, list]
|
|
operation_modes:
|
|
description: Overrides the supported operation modes. Provide the supported `preset_mode` values for your device.
|
|
required: false
|
|
type: list
|
|
controller_modes:
|
|
description: Overrides the supported controller modes. Provide the supported `hvac_mode` values for your device.
|
|
required: false
|
|
type: list
|
|
default_controller_mode:
|
|
description: Overrides the default controller mode. Any Home Assistant `hvac_mode` can be configured. This can, for example, be set to "cool" for cooling-only devices.
|
|
required: false
|
|
default: "heat"
|
|
type: string
|
|
on_off_address:
|
|
description: KNX address for switching the climate device on/off. *DPT 1*
|
|
required: false
|
|
type: [string, list]
|
|
on_off_invert:
|
|
description: Value for switching the climate device on/off is inverted.
|
|
required: false
|
|
default: false
|
|
type: boolean
|
|
on_off_state_address:
|
|
description: KNX address for gathering the current state (on/off) of the climate device. *DPT 1*
|
|
required: false
|
|
type: [string, list]
|
|
min_temp:
|
|
description: Override the minimum temperature.
|
|
required: false
|
|
type: float
|
|
max_temp:
|
|
description: Override the maximum temperature.
|
|
required: false
|
|
type: float
|
|
entity_category:
|
|
description: The [category](https://developers.home-assistant.io/docs/core/entity#generic-properties) of the entity.
|
|
required: false
|
|
type: string
|
|
default: None
|
|
{% endconfiguration %}
|
|
|
|
## Cover
|
|
|
|
The KNX cover platform is used as an interface to KNX covers.
|
|
|
|
<div class='note'>
|
|
|
|
Unlike most KNX devices, Home Assistant defines 0% as closed and 100% as fully open in regards to covers. The corresponding value inversion is done internally by the KNX integration.
|
|
|
|
Home Assistant will, by default, `close` a cover by moving it in the `DOWN` direction in the KNX nomenclature, and `open` a cover by moving it in the `UP` direction.
|
|
|
|
</div>
|
|
|
|
To use your KNX covers in your installation, add the following lines to your top level [KNX Integration](/integrations/knx) configuration key in `configuration.yaml`:
|
|
|
|
```yaml
|
|
# Example configuration.yaml entry
|
|
knx:
|
|
cover:
|
|
- name: "Kitchen shutter"
|
|
move_long_address: "3/0/0"
|
|
move_short_address: "3/0/1"
|
|
stop_address: "3/0/4"
|
|
position_address: "3/0/3"
|
|
position_state_address: "3/0/2"
|
|
travelling_time_down: 51
|
|
travelling_time_up: 61
|
|
```
|
|
|
|
{% configuration %}
|
|
name:
|
|
description: A name for this device used within Home Assistant.
|
|
required: false
|
|
default: KNX Cover
|
|
type: string
|
|
move_long_address:
|
|
description: KNX group address for moving the cover full up or down. *DPT 1*
|
|
required: false
|
|
type: [string, list]
|
|
move_short_address:
|
|
description: KNX group address for moving the cover stepwise up or down. Used by some covers also as the means to stop the cover. Stepwise moves are only mapped to tilt angle functions in Home Assistant, as no stepwise move of cover position is generally supported by the architecture. If tilt angle is not supported, prefer the use of a `stop_address`. *DPT 1*
|
|
required: false
|
|
type: [string, list]
|
|
stop_address:
|
|
description: KNX group address for stopping the current movement of the cover. *DPT 1*
|
|
required: false
|
|
type: [string, list]
|
|
position_address:
|
|
description: KNX group address for moving the cover to the dedicated position. *DPT 5.001*
|
|
required: false
|
|
type: [string, list]
|
|
position_state_address:
|
|
description: Separate KNX group address for requesting the current position of the cover. *DPT 5.001*
|
|
required: false
|
|
type: [string, list]
|
|
angle_address:
|
|
description: KNX group address for tilting the cover to the dedicated angle. *DPT 5.001*
|
|
required: false
|
|
type: [string, list]
|
|
angle_state_address:
|
|
description: Separate KNX group address for requesting the current tilt angle of the cover. *DPT 5.001*
|
|
required: false
|
|
type: [string, list]
|
|
travelling_time_down:
|
|
description: Time cover needs to travel down in seconds. Needed to calculate the intermediate positions of cover while traveling.
|
|
required: false
|
|
default: 25
|
|
type: integer
|
|
travelling_time_up:
|
|
description: Time cover needs to travel up in seconds. Needed to calculate the intermediate positions of cover while traveling.
|
|
required: false
|
|
default: 25
|
|
type: integer
|
|
invert_updown:
|
|
description: Set this to `true` to invert the up/down commands from/to your KNX actuator. Default is to consider `UP` (0) as opening of a cover and `DOWN` (1) as closing of a cover.
|
|
required: false
|
|
default: false
|
|
type: boolean
|
|
invert_position:
|
|
description: Set this to `true` if your actuator reports fully down position as 0% in KNX.
|
|
required: false
|
|
default: false
|
|
type: boolean
|
|
invert_angle:
|
|
description: Set this to `true` if your actuator reports fully closed tilt as 0% in KNX.
|
|
required: false
|
|
default: false
|
|
type: boolean
|
|
device_class:
|
|
description: Sets the [class of the device](/integrations/cover/), changing the device state and icon that is displayed on the frontend.
|
|
required: false
|
|
type: string
|
|
entity_category:
|
|
description: The [category](https://developers.home-assistant.io/docs/core/entity#generic-properties) of the entity.
|
|
required: false
|
|
type: string
|
|
default: None
|
|
{% endconfiguration %}
|
|
|
|
## Date
|
|
|
|
The KNX date platform allows to send date values to the KNX bus and update its state from received telegrams. It can optionally respond to read requests from the KNX bus.
|
|
|
|
<div class='note'>
|
|
|
|
Date entities without a `state_address` will restore their last known state after Home Assistant was restarted.
|
|
|
|
Dates that have a `state_address` configured request their current state from the KNX bus.
|
|
|
|
</div>
|
|
|
|
<div class='note'>
|
|
|
|
DPT 11.001 covers the range 1990 to 2089. Year values outside of this range are not allowed.
|
|
|
|
</div>
|
|
|
|
```yaml
|
|
# Example configuration.yaml entry
|
|
knx:
|
|
date:
|
|
- name: "Date"
|
|
address: "0/0/2"
|
|
state_address: "0/0/2"
|
|
```
|
|
|
|
{% configuration %}
|
|
name:
|
|
description: A name for this device used within Home Assistant.
|
|
required: false
|
|
type: string
|
|
address:
|
|
description: The group address to which new values will be sent. *DPT 11.001*
|
|
required: true
|
|
type: [string, list]
|
|
state_address:
|
|
description: Group address for retrieving the state from the KNX bus. *DPT 11.001*
|
|
required: false
|
|
type: [string, list]
|
|
respond_to_read:
|
|
description: Respond to GroupValueRead telegrams received to the configured `address`.
|
|
required: false
|
|
type: boolean
|
|
default: false
|
|
sync_state:
|
|
description: Actively read the value from the bus. The maximum time interval (`<minutes>`) is 1440. The following values are valid
|
|
|
|
- `true` equivalent to "expire 60" (default)
|
|
|
|
- `false` no GroupValueRead telegrams will be sent to the bus
|
|
|
|
- `every <minutes>` to update it regularly every \<minutes\>
|
|
|
|
- `expire <minutes>` to read the state from the KNX bus when no telegram was received for \<minutes\>
|
|
|
|
- `<minutes>` equivalent to "expire \<minutes\>"
|
|
|
|
- `init` to just initialize the state on startup
|
|
|
|
required: false
|
|
type: [boolean, string, integer]
|
|
default: true
|
|
entity_category:
|
|
description: The [category](https://developers.home-assistant.io/docs/core/entity#generic-properties) of the entity.
|
|
required: false
|
|
type: string
|
|
default: None
|
|
{% endconfiguration %}
|
|
|
|
## DateTime
|
|
|
|
The KNX datetime platform allows to send datetime values to the KNX bus and update its state from received telegrams. It can optionally respond to read requests from the KNX bus.
|
|
|
|
<div class='note'>
|
|
|
|
Date entities without a `state_address` will restore their last known state after Home Assistant was restarted.
|
|
|
|
DateTimes that have a `state_address` configured request their current state from the KNX bus.
|
|
|
|
</div>
|
|
|
|
<div class='note'>
|
|
|
|
System timezone is used as DPT 19.001 doesn't provide timezone information.
|
|
Year values outside of the range 1900 to 2155 are invalid.
|
|
|
|
</div>
|
|
|
|
```yaml
|
|
# Example configuration.yaml entry
|
|
knx:
|
|
datetime:
|
|
- name: "DateTime"
|
|
address: "0/0/3"
|
|
state_address: "0/0/4"
|
|
```
|
|
|
|
{% configuration %}
|
|
name:
|
|
description: A name for this device used within Home Assistant.
|
|
required: false
|
|
type: string
|
|
address:
|
|
description: The group address to which new values will be sent. *DPT 19.001*
|
|
required: true
|
|
type: [string, list]
|
|
state_address:
|
|
description: Group address for retrieving the state from the KNX bus. *DPT 19.001*
|
|
required: false
|
|
type: [string, list]
|
|
respond_to_read:
|
|
description: Respond to GroupValueRead telegrams received to the configured `address`.
|
|
required: false
|
|
type: boolean
|
|
default: false
|
|
sync_state:
|
|
description: Actively read the value from the bus. The maximum time interval (`<minutes>`) is 1440. The following values are valid
|
|
|
|
- `true` equivalent to "expire 60" (default)
|
|
|
|
- `false` no GroupValueRead telegrams will be sent to the bus
|
|
|
|
- `every <minutes>` to update it regularly every \<minutes\>
|
|
|
|
- `expire <minutes>` to read the state from the KNX bus when no telegram was received for \<minutes\>
|
|
|
|
- `<minutes>` equivalent to "expire \<minutes\>"
|
|
|
|
- `init` to just initialize the state on startup
|
|
|
|
required: false
|
|
type: [boolean, string, integer]
|
|
default: true
|
|
entity_category:
|
|
description: The [category](https://developers.home-assistant.io/docs/core/entity#generic-properties) of the entity.
|
|
required: false
|
|
type: string
|
|
default: None
|
|
{% endconfiguration %}
|
|
|
|
## Fan
|
|
|
|
The KNX fan integration is used to control KNX fans. Following control types are supported:
|
|
|
|
- Percentage controlled: Fans that set the percentage directly from 0-100%.
|
|
- Step controlled: Fans which have a fixed amount of steps to set. The integration will convert percentage to step automatically. The `max_step` attribute is set to the number of steps of the fan, not counting the `off`-step. Example: A fan supports the steps 0 to 3. To use this fan the `max_step` attribute has to be set to `3`. The integration will convert the percentage `66 %` to the step `2` when sending data to KNX.
|
|
|
|
To use your KNX fan in your installation, add the following lines to your top level [KNX Integration](/integrations/knx) configuration key in `configuration.yaml`:
|
|
|
|
```yaml
|
|
# Example configuration.yaml entry
|
|
knx:
|
|
fan:
|
|
- name: "Ceiling fan"
|
|
address: "9/0/1"
|
|
state_address: "9/0/2"
|
|
```
|
|
|
|
{% configuration %}
|
|
name:
|
|
description: A name for this device used within Home Assistant.
|
|
required: false
|
|
type: string
|
|
address:
|
|
description: KNX group address for setting the percentage or step of the fan. *DPT 5.001* or *DPT 5.010*
|
|
required: true
|
|
type: [string, list]
|
|
state_address:
|
|
description: KNX group address for retrieving the percentage or step of the fan. *DPT 5.001* or *DPT 5.010*
|
|
required: false
|
|
type: [string, list]
|
|
oscillation_address:
|
|
description: KNX group address for switching the fan oscillation on or off. *DPT 1*
|
|
required: false
|
|
type: [string, list]
|
|
oscillation_state_address:
|
|
description: KNX group address for retrieving the state of the fan oscillation. *DPT 1*
|
|
required: false
|
|
type: [string, list]
|
|
max_step:
|
|
description: The maximum amount of steps for a step-controlled fan. If set, the integration will convert percentages to steps automatically.
|
|
required: false
|
|
type: integer
|
|
entity_category:
|
|
description: The [category](https://developers.home-assistant.io/docs/core/entity#generic-properties) of the entity.
|
|
required: false
|
|
type: string
|
|
default: None
|
|
{% endconfiguration %}
|
|
|
|
## Light
|
|
|
|
The KNX light integration is used as an interface to control KNX actuators for lighting applications such as:
|
|
|
|
- Switching actuators
|
|
- Dimming actuators
|
|
- LED controllers
|
|
- DALI gateways
|
|
|
|
To use your KNX light in your installation, add the following lines to your top level [KNX Integration](/integrations/knx) configuration key in `configuration.yaml`:
|
|
|
|
```yaml
|
|
# Example configuration.yaml entry
|
|
knx:
|
|
light:
|
|
- name: "Kitchen"
|
|
address: "1/0/9"
|
|
```
|
|
|
|
{% configuration %}
|
|
address:
|
|
description: KNX group address for switching the light on and off. *DPT 1.001*
|
|
required: true
|
|
type: [string, list]
|
|
state_address:
|
|
description: KNX group address for retrieving the switch state of the light. *DPT 1.001*
|
|
required: false
|
|
type: [string, list]
|
|
name:
|
|
description: A name for this device used within Home Assistant.
|
|
required: false
|
|
type: string
|
|
brightness_address:
|
|
description: KNX group address for setting the brightness of the light in percent (absolute dimming). *DPT 5.001*
|
|
required: false
|
|
type: [string, list]
|
|
brightness_state_address:
|
|
description: KNX group address for retrieving the brightness of the light in percent. *DPT 5.001*
|
|
required: false
|
|
type: [string, list]
|
|
color_address:
|
|
description: KNX group address for setting the RGB color of the light. *DPT 232.600*
|
|
required: false
|
|
type: [string, list]
|
|
color_state_address:
|
|
description: KNX group address for retrieving the RGB color of the light. *DPT 232.600*
|
|
required: false
|
|
type: [string, list]
|
|
rgbw_address:
|
|
description: KNX group address for setting the RGBW color of the light. *DPT 251.600*
|
|
required: false
|
|
type: [string, list]
|
|
rgbw_state_address:
|
|
description: KNX group address for retrieving the RGBW color of the light. *DPT 251.600*
|
|
required: false
|
|
type: [string, list]
|
|
hue_address:
|
|
description: KNX group address for setting the hue of the light color in degrees. *DPT 5.003*
|
|
required: false
|
|
type: [string, list]
|
|
hue_state_address:
|
|
description: KNX group address for retrieving the hue of the light color in degrees. *DPT 5.003*
|
|
required: false
|
|
type: [string, list]
|
|
saturation_address:
|
|
description: KNX group address for setting the saturation of the light color in percent. *DPT 5.001*
|
|
required: false
|
|
type: [string, list]
|
|
saturation_state_address:
|
|
description: KNX group address for retrieving the saturation of the light color in percent. *DPT 5.001*
|
|
required: false
|
|
type: [string, list]
|
|
xyy_address:
|
|
description: KNX group address for setting the xyY color of the light. *DPT 242.600*
|
|
required: false
|
|
type: [string, list]
|
|
xyy_state_address:
|
|
description: KNX group address for retrieving the xyY color of the light. *DPT 242.600*
|
|
required: false
|
|
type: [string, list]
|
|
individual_colors:
|
|
description: Used when the actuator only supports individual group addresses for colors. When `individual_colors` is used the root `address` key may be omitted.
|
|
required: false
|
|
type: map
|
|
keys:
|
|
red:
|
|
description: Group addresses for the red component.
|
|
type: map
|
|
required: true
|
|
keys:
|
|
address:
|
|
description: KNX group address to switch the red component. *DPT 1.001*
|
|
type: [string, list]
|
|
required: false
|
|
state_address:
|
|
description: KNX group address for the state of the red component. *DPT 1.001*
|
|
type: [string, list]
|
|
required: false
|
|
brightness_address:
|
|
description: KNX group address to set the brightness of the red component. *DPT 5.001*
|
|
type: [string, list]
|
|
required: true
|
|
brightness_state_address:
|
|
description: KNX group address for the current brightness of the red component. *DPT 5.001*
|
|
type: [string, list]
|
|
required: false
|
|
green:
|
|
description: Group addresses for the green component. Same keys available as for red component above.
|
|
type: map
|
|
required: true
|
|
blue:
|
|
description: Group addresses for the blue component. Same keys available as for red component above.
|
|
type: map
|
|
required: true
|
|
white:
|
|
description: Group addresses for the white component. Same keys available as for red component above.
|
|
type: map
|
|
required: false
|
|
color_temperature_address:
|
|
description: KNX group address for setting the color temperature of the light. *DPT 5.001, 7.600 or 9 based on color_temperature_mode*
|
|
required: false
|
|
type: [string, list]
|
|
color_temperature_state_address:
|
|
description: KNX group address for retrieving the color temperature of the light. *DPT 5.001, 7.600 or 9 based on color_temperature_mode*
|
|
required: false
|
|
type: [string, list]
|
|
color_temperature_mode:
|
|
description: Color temperature group address data type. `absolute` for color temperature in Kelvin (2 byte unsigned integer). *color_temperature_address -> DPT 7.600*. `absolute_float` for color temperature represented in 2 byte float. *color_temperature_address -> DPT 9*. `relative` color temperature in percent cold white (0% warmest; 100% coldest). *color_temperature_address -> DPT 5.001*
|
|
required: false
|
|
type: string
|
|
default: absolute
|
|
min_kelvin:
|
|
description: Warmest possible color temperature in Kelvin. Used in combination with `color_temperature_address`.
|
|
required: false
|
|
type: integer
|
|
default: 2700
|
|
max_kelvin:
|
|
description: Coldest possible color temperature in Kelvin. Used in combination with `color_temperature_address`.
|
|
required: false
|
|
type: integer
|
|
default: 6000
|
|
entity_category:
|
|
description: The [category](https://developers.home-assistant.io/docs/core/entity#generic-properties) of the entity.
|
|
required: false
|
|
type: string
|
|
default: None
|
|
{% endconfiguration %}
|
|
|
|
Many KNX devices can change their state internally without a message to the switch address on the KNX bus, e.g., if you configure a scene or a timer on a channel. The optional `state_address` can be used to inform Home Assistant about these state changes. If a KNX message is seen on the bus addressed to the given `state_address` (in most cases from the light actuator), it will overwrite the state of the object.
|
|
|
|
For switching/light actuators that are only controlled by a single group address and don't have dedicated state group objects you can set `state_address` to the same value as `address`.
|
|
|
|
*Note on tunable white:* Home Assistant uses Mireds as the unit for color temperature, whereas KNX typically uses Kelvin. The Kelvin/Mireds relationship is reciprocal, not linear, therefore the color temperature pickers (sliders) in Home Assistant may not align with ones of KNX visualizations. This is the expected behavior.
|
|
|
|
### Extended configuration examples
|
|
|
|
```yaml
|
|
knx:
|
|
light:
|
|
# dimmable light
|
|
# color mode: brightness
|
|
- name: "Dimmable light"
|
|
address: "1/0/9"
|
|
state_address: "1/1/9"
|
|
brightness_address: "1/2/9"
|
|
brightness_state_address: "1/3/9"
|
|
# XYY light
|
|
# color mode: xy
|
|
- name: "XYY light"
|
|
address: "1/0/9"
|
|
state_address: "1/1/9"
|
|
brightness_address: "1/2/9" # optional - if not set brightness will be sent over the xyy data point
|
|
brightness_state_address: "1/3/9"
|
|
xyy_address: "1/4/9"
|
|
xyy_state_address: "1/5/9"
|
|
# HS light
|
|
# color mode: hs
|
|
- name: "HS light"
|
|
address: "1/0/9"
|
|
state_address: "1/1/9"
|
|
brightness_address: "1/2/9" # required for HS
|
|
brightness_state_address: "1/3/9"
|
|
hue_address: "1/4/8"
|
|
hue_state_address: "1/5/8" # required for HS
|
|
saturation_address: "1/4/9"
|
|
saturation_state_address: "1/5/9" # required for HS
|
|
# RGB light
|
|
# color mode: rgb
|
|
- name: "RGB light"
|
|
address: "1/0/9"
|
|
state_address: "1/1/9"
|
|
brightness_address: "1/2/9" # optional for RGB lights
|
|
brightness_state_address: "1/3/9"
|
|
color_address: "1/4/9"
|
|
color_state_address: "1/5/9"
|
|
# RGBW light
|
|
# color mode: rgbw
|
|
- name: "RGBW light"
|
|
address: "0/4/83"
|
|
state_address: "0/4/84"
|
|
brightness_address: "0/4/85" # optional for RGBW lights
|
|
brightness_state_address: "0/4/86"
|
|
rgbw_address: "0/4/87"
|
|
rgbw_state_address: "0/4/88"
|
|
# RGB(W) individual object light
|
|
# color mode: rgb / rgbw
|
|
- name: "RGBW individual light"
|
|
address: "1/0/9" # optional for individual color lights
|
|
individual_colors:
|
|
red:
|
|
brightness_address: "0/4/61"
|
|
brightness_state_address: "0/5/61"
|
|
green:
|
|
brightness_address: "0/4/62"
|
|
brightness_state_address: "0/5/62"
|
|
blue:
|
|
brightness_address: "0/4/63"
|
|
brightness_state_address: "0/5/63"
|
|
white:
|
|
brightness_address: "0/4/64"
|
|
brightness_state_address: "0/5/64"
|
|
# tunable white light
|
|
# color mode: color_temp
|
|
- name: "TW light"
|
|
address: "1/0/21"
|
|
state_address: "1/1/21"
|
|
brightness_address: "1/2/21"
|
|
brightness_state_address: "1/3/21"
|
|
color_temperature_address: "1/4/21"
|
|
color_temperature_state_address: "1/5/21"
|
|
color_temperature_mode: absolute
|
|
min_kelvin: 2550
|
|
max_kelvin: 6200
|
|
# actuator without dedicated state group object
|
|
# color mode: onoff
|
|
- name: "Simple light"
|
|
address: "1/0/5"
|
|
state_address: "1/0/5"
|
|
```
|
|
|
|
## Notify
|
|
|
|
The KNX notify platform allows you to send notifications to [KNX](https://www.knx.org/) devices as DPT16 strings.
|
|
|
|
```yaml
|
|
knx:
|
|
notify:
|
|
- name: "Alarm"
|
|
address: "5/1/10"
|
|
```
|
|
|
|
{% configuration %}
|
|
address:
|
|
description: KNX group address of the notification. *DPT 16.000*
|
|
required: true
|
|
type: [string, list]
|
|
name:
|
|
description: A name for this device used within Home Assistant.
|
|
required: false
|
|
type: string
|
|
type:
|
|
description: A DPT identifier representing a text value ("string" or "latin_1" - see [KNX Sensor](#sensor)) used to encode the notification.
|
|
required: false
|
|
default: "latin_1"
|
|
type: string
|
|
{% endconfiguration %}
|
|
|
|
## Number
|
|
|
|
The KNX number platform allows to send generic numeric values to the KNX bus and update its state from received telegrams. It can optionally respond to read requests from the KNX bus.
|
|
|
|
<div class='note'>
|
|
|
|
Number entities without a `state_address` will restore their last known state after Home Assistant was restarted.
|
|
|
|
Numbers that have a `state_address` configured request their current state from the KNX bus.
|
|
|
|
</div>
|
|
|
|
```yaml
|
|
# Example configuration.yaml entry
|
|
knx:
|
|
number:
|
|
- name: "Duration"
|
|
address: "0/0/1"
|
|
type: time_period_sec
|
|
- name: "Volume"
|
|
address: "0/0/2"
|
|
state_address: "0/0/3"
|
|
type: percent
|
|
- name: "Temperature threshold"
|
|
address: "0/0/4"
|
|
respond_to_read: true
|
|
type: temperature
|
|
min: 20
|
|
max: 24.5
|
|
step: 0.1
|
|
mode: slider
|
|
```
|
|
|
|
{% configuration %}
|
|
name:
|
|
description: A name for this device used within Home Assistant.
|
|
required: false
|
|
type: string
|
|
address:
|
|
description: The group address to which new values will be sent.
|
|
required: true
|
|
type: [string, list]
|
|
state_address:
|
|
description: Group address for retrieving the state from the KNX bus.
|
|
required: false
|
|
type: [string, list]
|
|
type:
|
|
description: Any supported type of [KNX Sensor](#sensor) representing a numeric value (e.g., "percent" or "temperature").
|
|
required: true
|
|
type: [string, integer]
|
|
respond_to_read:
|
|
description: Respond to GroupValueRead telegrams received to the configured `address`.
|
|
required: false
|
|
type: boolean
|
|
default: false
|
|
min:
|
|
description: Minimum value that can be sent. Defaults to the `type` DPT minimum value.
|
|
required: false
|
|
type: float
|
|
max:
|
|
description: Maximum value that can be sent. Defaults to the `type` DPT maximum value.
|
|
required: false
|
|
type: float
|
|
step:
|
|
description: Step value. Defaults to the step size defined for the DPT in the KNX specifications.
|
|
required: false
|
|
type: float
|
|
mode:
|
|
description: Specifies the mode used in the UI. `auto`, `box` or `slider` are valid.
|
|
required: false
|
|
type: string
|
|
default: auto
|
|
entity_category:
|
|
description: The [category](https://developers.home-assistant.io/docs/core/entity#generic-properties) of the entity.
|
|
required: false
|
|
type: string
|
|
default: None
|
|
{% endconfiguration %}
|
|
|
|
## Scene
|
|
|
|
The KNX scenes platform allows you to trigger [KNX](https://www.knx.org/) scenes. These entities are write-only.
|
|
|
|
```yaml
|
|
# Example configuration.yaml entry
|
|
knx:
|
|
scene:
|
|
- name: "Romantic"
|
|
address: 8/8/8
|
|
scene_number: 23
|
|
```
|
|
|
|
{% configuration %}
|
|
address:
|
|
description: KNX group address for the scene. *DPT 17.001*
|
|
required: true
|
|
type: [string, list]
|
|
scene_number:
|
|
description: KNX scene number to be activated (range 1..64 ).
|
|
required: true
|
|
type: integer
|
|
name:
|
|
description: A name for this device used within Home Assistant.
|
|
required: false
|
|
type: string
|
|
entity_category:
|
|
description: The [category](https://developers.home-assistant.io/docs/core/entity#generic-properties) of the entity.
|
|
required: false
|
|
type: string
|
|
default: None
|
|
{% endconfiguration %}
|
|
|
|
## Select
|
|
|
|
The KNX select platform allows the user to define a list of values that can be selected via the frontend and can be used within conditions of automation. When a user selects a new item, the assigned generic raw payload is sent to the KNX bus. A received telegram updates the state of the select entity. It can optionally respond to read requests from the KNX bus.
|
|
|
|
<div class='note'>
|
|
|
|
Select entities without a `state_address` will restore their last known state after Home Assistant was restarted.
|
|
|
|
Selects that have a `state_address` configured request their current state from the KNX bus.
|
|
|
|
</div>
|
|
|
|
```yaml
|
|
# Example configuration.yaml entry
|
|
knx:
|
|
select:
|
|
- name: "DPT 2 selector"
|
|
address: "0/0/1"
|
|
payload_length: 0
|
|
options:
|
|
- option: "No control"
|
|
payload: 0
|
|
- option: "Control On"
|
|
payload: 0b10
|
|
- option: "Control Off"
|
|
payload: 0b11
|
|
- name: "DHWMode"
|
|
address: "0/0/2"
|
|
state_address: "0/0/3"
|
|
payload_length: 1
|
|
options:
|
|
- option: "Auto"
|
|
payload: 0
|
|
- option: "LegioProtect"
|
|
payload: 1
|
|
- option: "Normal"
|
|
payload: 2
|
|
- option: "Reduced"
|
|
payload: 3
|
|
- option: "Off/FrostProtect"
|
|
payload: 4
|
|
```
|
|
|
|
{% configuration %}
|
|
name:
|
|
description: A name for this device used within Home Assistant.
|
|
required: false
|
|
type: string
|
|
address:
|
|
description: The group address to which new values will be sent.
|
|
required: true
|
|
type: [string, list]
|
|
state_address:
|
|
description: Group address for retrieving the state from the KNX bus.
|
|
required: false
|
|
type: [string, list]
|
|
payload_length:
|
|
description: The length of the payload expected for the DPT. Use `0` for DPT 1, 2 or 3.
|
|
required: true
|
|
type: integer
|
|
options:
|
|
description: List of options to choose from. Each `option` and `payload` have to be unique.
|
|
type: list
|
|
required: true
|
|
keys:
|
|
option:
|
|
description: The name of the option used to trigger the assigned `payload`.
|
|
required: true
|
|
type: string
|
|
payload:
|
|
description: The raw payload assigned to the `option`.
|
|
required: true
|
|
type: integer
|
|
respond_to_read:
|
|
description: Respond to GroupValueRead telegrams received to the configured `address`.
|
|
required: false
|
|
type: boolean
|
|
default: false
|
|
sync_state:
|
|
description: Actively read the value from the bus. The maximum time interval (`<minutes>`) is 1440. The following values are valid
|
|
|
|
- `true` equivalent to "expire 60" (default)
|
|
|
|
- `false` no GroupValueRead telegrams will be sent to the bus
|
|
|
|
- `every <minutes>` to update it regularly every \<minutes\>
|
|
|
|
- `expire <minutes>` to read the state from the KNX bus when no telegram was received for \<minutes\>
|
|
|
|
- `<minutes>` equivalent to "expire \<minutes\>"
|
|
|
|
- `init` to just initialize the state on startup
|
|
|
|
required: false
|
|
type: [boolean, string, integer]
|
|
default: true
|
|
entity_category:
|
|
description: The [category](https://developers.home-assistant.io/docs/core/entity#generic-properties) of the entity.
|
|
required: false
|
|
type: string
|
|
default: None
|
|
{% endconfiguration %}
|
|
|
|
## Sensor
|
|
|
|
The KNX sensor platform allows you to monitor [KNX](https://www.knx.org/) sensors.
|
|
|
|
Sensors are read-only. To write to the KNX bus configure a [Number](#number), an exposure [KNX Integration Expose](/integrations/knx/#exposing-entity-states-entity-attributes-or-time-to-knx-bus) or use the `knx.send` service.
|
|
|
|
```yaml
|
|
# Example configuration.yaml entry
|
|
knx:
|
|
sensor:
|
|
- name: "Heating Valve 1"
|
|
state_address: "2/0/0"
|
|
type: percent
|
|
```
|
|
|
|
In order to actively read the sensor data from the bus every 30 minutes you can add the following lines to your `configuration.yaml`:
|
|
|
|
```yaml
|
|
# Example configuration.yaml entry
|
|
knx:
|
|
sensor:
|
|
- name: "Heating Valve 1"
|
|
state_address: "2/0/0"
|
|
type: percent
|
|
sync_state: every 30
|
|
```
|
|
|
|
{% configuration %}
|
|
state_address:
|
|
description: KNX group address of the sensor.
|
|
required: true
|
|
type: [string, list]
|
|
type:
|
|
description: A type from the [value types table](/integrations/knx/#value-types) below must be defined. The DPT of the group address should match the expected KNX DPT to be parsed correctly.
|
|
required: true
|
|
type: [string, integer]
|
|
name:
|
|
description: A name for this device used within Home Assistant.
|
|
required: false
|
|
type: string
|
|
sync_state:
|
|
description: Actively read the value from the bus. The maximum time interval (`<minutes>`) is 1440. The following values are valid
|
|
|
|
- `true` equivalent to "expire 60" (default)
|
|
|
|
- `false` no GroupValueRead telegrams will be sent to the bus
|
|
|
|
- `every <minutes>` to update it regularly every \<minutes\>
|
|
|
|
- `expire <minutes>` to read the state from the KNX bus when no telegram was received for \<minutes\>
|
|
|
|
- `<minutes>` equivalent to "expire \<minutes\>"
|
|
|
|
- `init` to just initialize the state on startup
|
|
|
|
required: false
|
|
type: [boolean, string, integer]
|
|
default: true
|
|
always_callback:
|
|
description: Defines if telegrams with equal payload as the previously received telegram should trigger a state update within Home Assistant.
|
|
required: false
|
|
type: boolean
|
|
default: false
|
|
state_class:
|
|
description: Sets the [state_class](https://developers.home-assistant.io/docs/core/entity/sensor#available-state-classes) of the sensor.
|
|
required: false
|
|
type: string
|
|
entity_category:
|
|
description: The [category](https://developers.home-assistant.io/docs/core/entity#generic-properties) of the entity.
|
|
required: false
|
|
type: string
|
|
default: None
|
|
device_class:
|
|
description: Overrides the [class of the device](/integrations/sensor/), changing the device state and icon that is displayed on the frontend.
|
|
required: false
|
|
type: string
|
|
{% endconfiguration %}
|
|
|
|
### Value types
|
|
|
|
| KNX DPT | type | size in byte | range | unit |
|
|
| ------: | ----------------------------- | -----------: | :------------------------: | -------------- |
|
|
| 5 | 1byte_unsigned | 1 | 0 ... 255 | |
|
|
| 5.001 | percent | 1 | 0 ... 100 | % |
|
|
| 5.003 | angle | 1 | 0 ... 360 | ° |
|
|
| 5.004 | percentU8 | 1 | 0 ... 255 | % |
|
|
| 5.005 | decimal_factor | 1 | 0 ... 255 | |
|
|
| 5.006 | tariff | 1 | 0 ... 254 | |
|
|
| 5.010 | pulse | 1 | 0 ... 255 | counter pulses |
|
|
| 6 | 1byte_signed | 1 | -128 ... 127 | |
|
|
| 6.001 | percentV8 | 1 | -128 ... 127 | % |
|
|
| 6.010 | counter_pulses | 1 | -128 ... 127 | counter pulses |
|
|
| 7 | 2byte_unsigned | 2 | 0 ... 65535 | |
|
|
| 7.001 | pulse_2byte | 2 | 0 ... 65535 | pulses |
|
|
| 7.002 | time_period_msec | 2 | 0 ... 65535 | ms |
|
|
| 7.003 | time_period_10msec | 2 | 0 ... 65535 | ms |
|
|
| 7.004 | time_period_100msec | 2 | 0 ... 65535 | ms |
|
|
| 7.005 | time_period_sec | 2 | 0 ... 65535 | s |
|
|
| 7.006 | time_period_min | 2 | 0 ... 65535 | min |
|
|
| 7.007 | time_period_hrs | 2 | 0 ... 65535 | h |
|
|
| 7.011 | length_mm | 2 | 0 ... 65535 | mm |
|
|
| 7.012 | current | 2 | 0 ... 65535 | mA |
|
|
| 7.013 | brightness | 2 | 0 ... 65535 | lx |
|
|
| 7.600 | color_temperature | 2 | 0 ... 65535 | K |
|
|
| 8 | 2byte_signed | 2 | -32768 ... 32767 | |
|
|
| 8.001 | pulse_2byte_signed | 2 | -32768 ... 32767 | pulses |
|
|
| 8.002 | delta_time_ms | 2 | -32768 ... 32767 | ms |
|
|
| 8.003 | delta_time_10ms | 2 | -32768 ... 32767 | ms |
|
|
| 8.004 | delta_time_100ms | 2 | -32768 ... 32767 | ms |
|
|
| 8.005 | delta_time_sec | 2 | -32768 ... 32767 | s |
|
|
| 8.006 | delta_time_min | 2 | -32768 ... 32767 | min |
|
|
| 8.007 | delta_time_hrs | 2 | -32768 ... 32767 | h |
|
|
| 8.010 | percentV16 | 2 | -32768 ... 32767 | % |
|
|
| 8.011 | rotation_angle | 2 | -32768 ... 32767 | ° |
|
|
| 8.012 | length_m | 2 | -32768 ... 32767 | m |
|
|
| 9 | 2byte_float | 2 | -671088.64 ... 670760.96 | |
|
|
| 9.001 | temperature | 2 | -273 ... 670760 | °C |
|
|
| 9.002 | temperature_difference_2byte | 2 | -670760 ... 670760 | K |
|
|
| 9.003 | temperature_a | 2 | -670760 ... 670760 | K/h |
|
|
| 9.004 | illuminance | 2 | 0 ... 670760 | lx |
|
|
| 9.005 | wind_speed_ms | 2 | 0 ... 670760 | m/s |
|
|
| 9.006 | pressure_2byte | 2 | 0 ... 670760 | Pa |
|
|
| 9.007 | humidity | 2 | 0 ... 670760 | % |
|
|
| 9.008 | ppm | 2 | -671088.64 ... 670760.96 | ppm |
|
|
| 9.009 | air_flow | 2 | -671088.64 ... 670760.96 | m³/h |
|
|
| 9.010 | time_1 | 2 | -670760 ... 670760 | s |
|
|
| 9.011 | time_2 | 2 | -670760 ... 670760 | ms |
|
|
| 9.020 | voltage | 2 | -671088.64 ... 670760.96 | mV |
|
|
| 9.021 | curr | 2 | -671088.64 ... 670760.96 | mA |
|
|
| 9.022 | power_density | 2 | -671088.64 ... 670760.96 | W/m² |
|
|
| 9.023 | kelvin_per_percent | 2 | -671088.64 ... 670760.96 | K/% |
|
|
| 9.024 | power_2byte | 2 | -671088.64 ... 670760.96 | kW |
|
|
| 9.025 | volume_flow | 2 | -671088.64 ... 670760.96 | l/h |
|
|
| 9.026 | rain_amount | 2 | -671088.64 ... 670760.96 | l/m² |
|
|
| 9.027 | temperature_f | 2 | -459.6 ... 670760 | °F |
|
|
| 9.028 | wind_speed_kmh | 2 | 0 ... 670760 | km/h |
|
|
| 9.029 | absolute_humidity | 2 | 0 ... 670760 | g/m³ |
|
|
| 9.030 | concentration_ugm3 | 2 | 0 ... 670760 | μg/m³ |
|
|
| 9.? | enthalpy | 2 | -671088.64 ... 670760.96 | H |
|
|
| 12 | 4byte_unsigned | 4 | 0 ... 4294967295 | |
|
|
| 12.001 | pulse_4_ucount | 4 | 0 ... 4294967295 | counter pulses |
|
|
| 12.100 | long_time_period_sec | 4 | 0 ... 4294967295 | s |
|
|
| 12.101 | long_time_period_min | 4 | 0 ... 4294967295 | min |
|
|
| 12.102 | long_time_period_hrs | 4 | 0 ... 4294967295 | h |
|
|
| 12.1200 | volume_liquid_litre | 4 | 0 ... 4294967295 | l |
|
|
| 12.1201 | volume_m3 | 4 | 0 ... 4294967295 | m³ |
|
|
| 13 | 4byte_signed | 4 | -2147483648 ... 2147483647 | |
|
|
| 13.001 | pulse_4byte | 4 | -2147483648 ... 2147483647 | counter pulses |
|
|
| 13.002 | flow_rate_m3h | 4 | -2147483648 ... 2147483647 | m³/h |
|
|
| 13.010 | active_energy | 4 | -2147483648 ... 2147483647 | Wh |
|
|
| 13.011 | apparant_energy | 4 | -2147483648 ... 2147483647 | VAh |
|
|
| 13.012 | reactive_energy | 4 | -2147483648 ... 2147483647 | VARh |
|
|
| 13.013 | active_energy_kwh | 4 | -2147483648 ... 2147483647 | kWh |
|
|
| 13.014 | apparant_energy_kvah | 4 | -2147483648 ... 2147483647 | kVAh |
|
|
| 13.015 | reactive_energy_kvarh | 4 | -2147483648 ... 2147483647 | kVARh |
|
|
| 13.016 | active_energy_mwh | 4 | -2147483648 ... 2147483647 | MWh |
|
|
| 13.100 | long_delta_timesec | 4 | -2147483648 ... 2147483647 | s |
|
|
| 14 | 4byte_float | 4 | | |
|
|
| 14.000 | acceleration | 4 | | m/s² |
|
|
| 14.001 | acceleration_angular | 4 | | rad/s² |
|
|
| 14.002 | activation_energy | 4 | | J/mol |
|
|
| 14.003 | activity | 4 | | s⁻¹ |
|
|
| 14.004 | mol | 4 | | mol |
|
|
| 14.005 | amplitude | 4 | | |
|
|
| 14.006 | angle_rad | 4 | | rad |
|
|
| 14.007 | angle_deg | 4 | | ° |
|
|
| 14.008 | angular_momentum | 4 | | J s |
|
|
| 14.009 | angular_velocity | 4 | | rad/s |
|
|
| 14.010 | area | 4 | | m² |
|
|
| 14.011 | capacitance | 4 | | F |
|
|
| 14.012 | charge_density_surface | 4 | | C/m² |
|
|
| 14.013 | charge_density_volume | 4 | | C/m³ |
|
|
| 14.014 | compressibility | 4 | | m²/N |
|
|
| 14.015 | conductance | 4 | | S |
|
|
| 14.016 | electrical_conductivity | 4 | | S/m |
|
|
| 14.017 | density | 4 | | kg/m³ |
|
|
| 14.018 | electric_charge | 4 | | C |
|
|
| 14.019 | electric_current | 4 | | A |
|
|
| 14.020 | electric_current_density | 4 | | A/m² |
|
|
| 14.021 | electric_dipole_moment | 4 | | C m |
|
|
| 14.022 | electric_displacement | 4 | | C/m² |
|
|
| 14.023 | electric_field_strength | 4 | | V/m |
|
|
| 14.024 | electric_flux | 4 | | c |
|
|
| 14.025 | electric_flux_density | 4 | | C/m² |
|
|
| 14.026 | electric_polarization | 4 | | C/m² |
|
|
| 14.027 | electric_potential | 4 | | V |
|
|
| 14.028 | electric_potential_difference | 4 | | V |
|
|
| 14.029 | electromagnetic_moment | 4 | | A m² |
|
|
| 14.030 | electromotive_force | 4 | | V |
|
|
| 14.031 | energy | 4 | | J |
|
|
| 14.032 | force | 4 | | N |
|
|
| 14.033 | frequency | 4 | | Hz |
|
|
| 14.034 | angular_frequency | 4 | | rad/s |
|
|
| 14.035 | heatcapacity | 4 | | J/K |
|
|
| 14.036 | heatflowrate | 4 | | W |
|
|
| 14.037 | heat_quantity | 4 | | J |
|
|
| 14.038 | impedance | 4 | | Ω |
|
|
| 14.039 | length | 4 | | m |
|
|
| 14.040 | light_quantity | 4 | | lm s |
|
|
| 14.041 | luminance | 4 | | cd/m² |
|
|
| 14.042 | luminous_flux | 4 | | lm |
|
|
| 14.043 | luminous_intensity | 4 | | cd |
|
|
| 14.044 | magnetic_field_strength | 4 | | A/m |
|
|
| 14.045 | magnetic_flux | 4 | | Wb |
|
|
| 14.046 | magnetic_flux_density | 4 | | T |
|
|
| 14.047 | magnetic_moment | 4 | | A m² |
|
|
| 14.048 | magnetic_polarization | 4 | | T |
|
|
| 14.049 | magnetization | 4 | | A/m |
|
|
| 14.050 | magnetomotive_force | 4 | | A |
|
|
| 14.051 | mass | 4 | | kg |
|
|
| 14.052 | mass_flux | 4 | | kg/s |
|
|
| 14.053 | momentum | 4 | | N/s |
|
|
| 14.054 | phaseanglerad | 4 | | rad |
|
|
| 14.055 | phaseangledeg | 4 | | ° |
|
|
| 14.056 | power | 4 | | W |
|
|
| 14.057 | powerfactor | 4 | | |
|
|
| 14.058 | pressure | 4 | | Pa |
|
|
| 14.059 | reactance | 4 | | Ω |
|
|
| 14.060 | resistance | 4 | | Ω |
|
|
| 14.061 | resistivity | 4 | | Ωm |
|
|
| 14.062 | self_inductance | 4 | | H |
|
|
| 14.063 | solid_angle | 4 | | sr |
|
|
| 14.064 | sound_intensity | 4 | | W/m² |
|
|
| 14.065 | speed | 4 | | m/s |
|
|
| 14.066 | stress | 4 | | Pa |
|
|
| 14.067 | surface_tension | 4 | | N/m |
|
|
| 14.068 | common_temperature | 4 | | °C |
|
|
| 14.069 | absolute_temperature | 4 | | K |
|
|
| 14.070 | temperature_difference | 4 | | K |
|
|
| 14.071 | thermal_capacity | 4 | | J/K |
|
|
| 14.072 | thermal_conductivity | 4 | | W/mK |
|
|
| 14.073 | thermoelectric_power | 4 | | V/K |
|
|
| 14.074 | time_seconds | 4 | | s |
|
|
| 14.075 | torque | 4 | | Nm |
|
|
| 14.076 | volume | 4 | | m³ |
|
|
| 14.077 | volume_flux | 4 | | m³/s |
|
|
| 14.078 | weight | 4 | | N |
|
|
| 14.079 | work | 4 | | J |
|
|
| 14.080 | apparent_power | 4 | | VA |
|
|
| 16.000 | string | 14 | ASCII | |
|
|
| 16.001 | latin_1 | 14 | ISO 8859-1 / Latin-1 | |
|
|
| 17.001 | scene_number | 1 | 1 ... 64 | |
|
|
|
|
### More examples
|
|
|
|
```yaml
|
|
# Example configuration.yaml entry
|
|
knx:
|
|
sensor:
|
|
- name: "Heating Valve 1"
|
|
state_address: "2/0/0"
|
|
sync_state: init
|
|
type: percent
|
|
- name: "Kitchen Temperature"
|
|
state_address: "6/2/1"
|
|
sync_state: every 60
|
|
type: temperature
|
|
state_class: measurement
|
|
```
|
|
|
|
## Switch
|
|
|
|
The KNX switch platform is used as an interface to switching actuators.
|
|
|
|
```yaml
|
|
knx:
|
|
switch:
|
|
- name: "Kitchen coffee maker"
|
|
address: "1/1/6"
|
|
```
|
|
|
|
{% configuration %}
|
|
address:
|
|
description: KNX group address for switching the switch on/off. *DPT 1*
|
|
required: true
|
|
type: [string, list]
|
|
name:
|
|
description: A name for this device used within Home Assistant.
|
|
required: false
|
|
default: KNX Switch
|
|
type: string
|
|
state_address:
|
|
description: Separate KNX group address for retrieving the switch state. *DPT 1*
|
|
required: false
|
|
type: [string, list]
|
|
invert:
|
|
description: Invert the telegrams payload before processing or sending.
|
|
required: false
|
|
type: boolean
|
|
default: false
|
|
respond_to_read:
|
|
description: Respond to GroupValueRead telegrams received to the configured `address`.
|
|
required: false
|
|
type: boolean
|
|
default: false
|
|
entity_category:
|
|
description: The [category](https://developers.home-assistant.io/docs/core/entity#generic-properties) of the entity.
|
|
required: false
|
|
type: string
|
|
default: None
|
|
device_class:
|
|
description: Sets the [class of the device](/integrations/switch/), changing the device state and icon that is displayed on the frontend.
|
|
required: false
|
|
type: string
|
|
{% endconfiguration %}
|
|
|
|
The optional `state_address` can be used to inform Home Assistant about state changes not triggered by a telegram to the `address` e.g., if you configure a timer on a channel. If a KNX message is seen on the bus addressed to the given state address, this will overwrite the state of the switch object.
|
|
|
|
Switch entities without a `state_address` will restore their last known state after Home Assistant was restarted.
|
|
Switches that have a `state_address` configured request their current state from the KNX bus.
|
|
|
|
## Text
|
|
|
|
The KNX text platform allows to send text values to the KNX bus and update its state from received telegrams. It can optionally respond to read requests from the KNX bus.
|
|
|
|
<div class='note'>
|
|
|
|
Text entities without a `state_address` will restore their last known state after Home Assistant was restarted.
|
|
|
|
Texts that have a `state_address` configured request their current state from the KNX bus.
|
|
|
|
</div>
|
|
|
|
```yaml
|
|
# Example configuration.yaml entry
|
|
knx:
|
|
text:
|
|
- name: "Info"
|
|
address: "0/0/1"
|
|
- name: "ASCII Info"
|
|
address: "0/0/2"
|
|
state_address: "0/0/3"
|
|
type: string
|
|
- name: "Greeting"
|
|
address: "0/0/4"
|
|
respond_to_read: true
|
|
```
|
|
|
|
{% configuration %}
|
|
name:
|
|
description: A name for this device used within Home Assistant.
|
|
required: false
|
|
type: string
|
|
address:
|
|
description: The group address to which new values will be sent.
|
|
required: true
|
|
type: [string, list]
|
|
state_address:
|
|
description: Group address for retrieving the state from the KNX bus.
|
|
required: false
|
|
type: [string, list]
|
|
type:
|
|
description: Either `latin_1` for DPT 16.001 or `string` for DPT 16.000 (ASCII).
|
|
required: false
|
|
type: [string, integer]
|
|
default: latin_1
|
|
respond_to_read:
|
|
description: Respond to GroupValueRead telegrams received to the configured `address`.
|
|
required: false
|
|
type: boolean
|
|
default: false
|
|
mode:
|
|
description: Specifies the mode used in the UI. `text` or `password` are valid.
|
|
required: false
|
|
type: string
|
|
default: text
|
|
entity_category:
|
|
description: The [category](https://developers.home-assistant.io/docs/core/entity#generic-properties) of the entity.
|
|
required: false
|
|
type: string
|
|
default: None
|
|
{% endconfiguration %}
|
|
|
|
## Time
|
|
|
|
The KNX time platform allows to send time values to the KNX bus and update its state from received telegrams. It can optionally respond to read requests from the KNX bus.
|
|
|
|
<div class='note'>
|
|
|
|
Time entities without a `state_address` will restore their last known state after Home Assistant was restarted.
|
|
|
|
Times that have a `state_address` configured request their current state from the KNX bus.
|
|
|
|
</div>
|
|
|
|
<div class='note'>
|
|
|
|
The `day` field of the time telegram will always be set to 0 (`no day`).
|
|
|
|
</div>
|
|
|
|
```yaml
|
|
# Example configuration.yaml entry
|
|
knx:
|
|
time:
|
|
- name: "Time"
|
|
address: "0/0/2"
|
|
state_address: "0/0/2"
|
|
```
|
|
|
|
{% configuration %}
|
|
name:
|
|
description: A name for this device used within Home Assistant.
|
|
required: false
|
|
type: string
|
|
address:
|
|
description: The group address to which new values will be sent. *DPT 10.001*
|
|
required: true
|
|
type: [string, list]
|
|
state_address:
|
|
description: Group address for retrieving the state from the KNX bus. *DPT 10.001*
|
|
required: false
|
|
type: [string, list]
|
|
respond_to_read:
|
|
description: Respond to GroupValueRead telegrams received to the configured `address`.
|
|
required: false
|
|
type: boolean
|
|
default: false
|
|
sync_state:
|
|
description: Actively read the value from the bus. The maximum time interval (`<minutes>`) is 1440. The following values are valid
|
|
|
|
- `true` equivalent to "expire 60" (default)
|
|
|
|
- `false` no GroupValueRead telegrams will be sent to the bus
|
|
|
|
- `every <minutes>` to update it regularly every \<minutes\>
|
|
|
|
- `expire <minutes>` to read the state from the KNX bus when no telegram was received for \<minutes\>
|
|
|
|
- `<minutes>` equivalent to "expire \<minutes\>"
|
|
|
|
- `init` to just initialize the state on startup
|
|
|
|
required: false
|
|
type: [boolean, string, integer]
|
|
default: true
|
|
entity_category:
|
|
description: The [category](https://developers.home-assistant.io/docs/core/entity#generic-properties) of the entity.
|
|
required: false
|
|
type: string
|
|
default: None
|
|
{% endconfiguration %}
|
|
|
|
## Weather
|
|
|
|
The KNX weather platform is used as an interface to KNX weather stations.
|
|
|
|
To use your KNX weather station in your installation, add the following lines to your top level [KNX Integration](/integrations/knx) configuration key in `configuration.yaml`:
|
|
|
|
```yaml
|
|
# Example configuration.yaml entry
|
|
knx:
|
|
weather:
|
|
- name: "Home"
|
|
address_temperature: "7/0/0"
|
|
address_brightness_south: "7/0/1"
|
|
address_brightness_west: "7/0/2"
|
|
address_brightness_east: "7/0/3"
|
|
address_brightness_north: "7/0/11"
|
|
address_wind_speed: "7/0/4"
|
|
address_rain_alarm: "7/0/5"
|
|
address_frost_alarm: "7/0/6"
|
|
address_wind_alarm: "7/0/7"
|
|
address_day_night: "7/0/8"
|
|
address_air_pressure: "7/0/9"
|
|
address_humidity: "7/0/10"
|
|
sync_state: true
|
|
```
|
|
|
|
{% configuration %}
|
|
name:
|
|
description: A name for this device used within Home Assistant.
|
|
required: false
|
|
default: KNX Weather
|
|
type: string
|
|
address_temperature:
|
|
description: KNX group address for reading current outside temperature from KNX bus. *DPT 9.001*
|
|
required: true
|
|
type: [string, list]
|
|
address_brightness_south:
|
|
description: KNX group address for reading current brightness to south coordinate from KNX bus. *DPT 9.004*
|
|
required: false
|
|
type: [string, list]
|
|
address_brightness_west:
|
|
description: KNX group address for reading current brightness to west coordinate from KNX bus. *DPT 9.004*
|
|
required: false
|
|
type: [string, list]
|
|
address_brightness_east:
|
|
description: KNX group address for reading current brightness to east coordinate from KNX bus. *DPT 9.004*
|
|
required: false
|
|
type: [string, list]
|
|
address_brightness_north:
|
|
description: KNX group address for reading current brightness to north coordinate from KNX bus. *DPT 9.004*
|
|
required: false
|
|
type: [string, list]
|
|
address_wind_bearing:
|
|
description: KNX group address for reading current wind bearing from KNX bus. *DPT 5.003*
|
|
required: false
|
|
type: [string, list]
|
|
address_wind_speed:
|
|
description: KNX group address for reading current wind speed from KNX bus. *DPT 9.005*
|
|
required: false
|
|
type: [string, list]
|
|
address_rain_alarm:
|
|
description: KNX group address for reading if rain alarm is on/off.
|
|
required: false
|
|
type: [string, list]
|
|
address_frost_alarm:
|
|
description: KNX group address for reading if frost alarm is on/off.
|
|
required: false
|
|
type: [string, list]
|
|
address_wind_alarm:
|
|
description: KNX group address for reading if wind alarm is on/off.
|
|
required: false
|
|
type: [string, list]
|
|
address_day_night:
|
|
description: KNX group address for reading if it's day/night.
|
|
required: false
|
|
type: [string, list]
|
|
address_air_pressure:
|
|
description: KNX address reading current air pressure. *DPT 9.006*
|
|
required: false
|
|
type: [string, list]
|
|
address_humidity:
|
|
description: KNX address for reading current humidity. *DPT 9.007*
|
|
required: false
|
|
type: [string, list]
|
|
sync_state:
|
|
description: Actively read the value from the bus. The maximum time interval (`<minutes>`) is 1440. The following values are valid
|
|
|
|
- `true` equivalent to "expire 60" (default)
|
|
|
|
- `false` no GroupValueRead telegrams will be sent to the bus
|
|
|
|
- `every <minutes>` to update it regularly every \<minutes\>
|
|
|
|
- `expire <minutes>` to read the state from the KNX bus when no telegram was received for \<minutes\>
|
|
|
|
- `<minutes>` equivalent to "expire \<minutes\>"
|
|
|
|
- `init` to just initialize the state on startup
|
|
|
|
required: false
|
|
type: [boolean, string, integer]
|
|
default: true
|
|
entity_category:
|
|
description: The [category](https://developers.home-assistant.io/docs/core/entity#generic-properties) of the entity.
|
|
required: false
|
|
type: string
|
|
default: None
|
|
{% endconfiguration %}
|
|
|
|
## Troubleshooting / Common issues
|
|
|
|
### Logs for the KNX integration
|
|
|
|
`xknx`, the library used for KNX communication, provides various logging handlers for monitoring and debug purposes.
|
|
Add the following lines to your Home Assistant `configuration.yaml` to activate them:
|
|
|
|
```yaml
|
|
logger:
|
|
default: warning
|
|
logs:
|
|
# For most debugging needs `xnx.log` and `xknx.telegram` are a good choice.
|
|
xknx: info # sets the level of all loggers
|
|
# Loggers for different layers of KNX communication
|
|
xknx.log: debug # provides general information (connection, etc.)
|
|
xknx.telegram: debug # logs telegrams before they are being processed or sent
|
|
xknx.cemi: debug # logs incoming and outgoing CEMI frames
|
|
xknx.data_secure: debug # logs Data Secure relevant information
|
|
xknx.ip_secure: debug # logs IP Secure relevant information
|
|
xknx.knx: debug # logs incoming and outgoing KNX/IP frames
|
|
xknx.raw_socket: warning # logs incoming UDP/TCP frames in raw hex format at socket level
|
|
# Loggers for xknx internals
|
|
xknx.state_updater: warning # provides information about the state updater
|
|
```
|
|
|
|
You can use the service `logger.set_level` to change the log level of a handler on a running instance.
|
|
{% my developer_call_service badge service="logger.set_level" %}
|
|
|
|
### Group address can not be read
|
|
|
|
Every `*_state_address` is read on startup sequentially if not configured differently. If you see the following errors in your log, a group address could not be read by a GroupValueRead request from Home Assistant in time.
|
|
|
|
```log
|
|
> Could not sync group address '1/2/3' (Entity name - Feature)
|
|
> Error: KNX bus did not respond in time (2.0 secs) to GroupValueRead request for: '1/2/3'
|
|
```
|
|
|
|
#### No group object (GO) assigned to the group address (GA) has the Read-Flag set in ETS
|
|
|
|
- Enable the read flag for *one* GO assigned to the GA. Use the one most likely to hold the current state (e.g., for a light entity's `brightness_state_address` the according GO of the dimming actuator).
|
|
|
|
#### Response telegrams are not passing a line coupler, router or other filter in the installation
|
|
|
|
- Assign the group addresses used by Home Assistant to the used interface in ETS if your interface application supports that. ETS will generate filter tables that are applied to your line couplers after updating their application.
|
|
- If your interface application doesn't support that, use a dummy device in ETS for Home Assistant. These can be found in the ETS online catalog. Assign it to the line your interface connects Home Assistant to and link its group objects to the group addresses you are using in Home Assistant.
|
|
|
|
#### Unresponsive system
|
|
|
|
- The timeout for logging the errors (2 seconds) is started when the GroupValueRead request is scheduled to be sent. On systems experiencing high loads sending can be delayed (e.g., Raspberry Pi running lots of integrations at startup).
|
|
Incoming response telegrams are always processed, so no information gets lost.
|
|
|
|
### Duplicate entities
|
|
|
|
If you find following error in your log you seem to have a duplicated entity in your configuration.
|
|
|
|
```log
|
|
Platform knx does not generate unique IDs. ID 1/2/3 already exists - ignoring platform.name
|
|
```
|
|
|
|
The `unique_id` for KNX entities is generated based on required configuration values.
|
|
|
|
- binary_sensor: `state_address`
|
|
- climate: `temperature_address` `target_temperature_state_address` `target_temperature_address` `setpoint_shift_address`
|
|
- cover: `move_long_address` `position_address`
|
|
- fan: `address`
|
|
- light: `address` or all combined `brightness_address` if only `individual_colors` is used
|
|
- notify: `address`
|
|
- scene: `address` and `scene_number`
|
|
- sensor: `state_address`
|
|
- switch: `address`
|
|
- weather: `address_temperature`
|
|
|
|