title: Modbus
|
||
description: Instructions on how to integrate modbus and platforms.
|
||
ha_category:
|
||
- Hub
|
||
ha_release: pre 0.7
|
||
ha_iot_class: Local Polling
|
||
ha_codeowners:
|
||
- '@janiversen'
|
||
ha_domain: modbus
|
||
ha_platforms:
|
||
- binary_sensor
|
||
- climate
|
||
- cover
|
||
- fan
|
||
- light
|
||
- sensor
|
||
- switch
|
||
ha_quality_scale: gold
|
||
ha_integration_type: integration
|
||
---
|
||
|
||
[modbus](http://www.modbus.org/) is a communication protocol to control PLCs (Programmable Logic Controller) and RTUs (Remote Terminal Unit).
|
||
|
||
The integration adheres strictly to the [protocol specification](https://www.modbus.org/docs/Modbus_Application_Protocol_V1_1b3.pdf) using [pymodbus](https://github.com/pymodbus-dev/pymodbus) for the protocol implementation.
|
||
|
||
The modbus integration supports all devices adhering to the modbus standard. The communication to the device/devices can be serial (rs-485), TCP, or UDP connections. The modbus integration allows multiple communication channels e.g. a serial port connection combined with one or more TCP connections.
|
||
|
||
# Configuring modbus communication
|
||
|
||
Configure the modbus communication with modbus devices. This is a general setup needed establish access to the device.
|
||
|
||
The modbus integration allows you to use multiple connections each with multiple sensors etc.
|
||
|
||
The modbus integration provides a number of parameters to help communicate with "difficult" devices, these parameters are independent of the type of communication.
|
||
|
||
{% configuration %}
|
||
delay:
|
||
description: "Time to delay sending messages in seconds after connecting.
|
||
Some modbus devices need a delay of typically 1-2 seconds after connection is established to prepare the communication.
|
||
If a device does not respond to messages after connecting, then try this parameter.
|
||
**Remark:** solely affect the first message."
|
||
required: false
|
||
default: 0
|
||
type: integer
|
||
message_wait_milliseconds:
|
||
description: "Time to wait in milliseconds between requests."
|
||
required: false
|
||
default: 30 for serial connection, 0 for all other connections.
|
||
type: integer
|
||
name:
|
||
description: "Name of this hub. Must be unique."
|
||
required: true
|
||
type: string
|
||
timeout:
|
||
description: "Timeout while waiting for a response in seconds."
|
||
required: false
|
||
default: 5
|
||
type: integer
|
||
type:
|
||
description: "Type of modbus."
|
||
required: true
|
||
type: list
|
||
keys:
|
||
tcp:
|
||
description: "TCP/IP connection with socket framer, used with Ethernet enabled devices."
|
||
udp:
|
||
description: "UDP connection with socket framer, rarely used."
|
||
rtuovertcp:
|
||
description: "TCP/IP connection with rtu framer, used when connection to modbus forwarders."
|
||
serial:
|
||
description: "Serial connection with RTU framer, used with TTY port or USB rs485 converter."
|
||
|
||
{% endconfiguration %}
|
||
|
||
## Configuring tcp connection
|
||
|
||
`type: tcp` is required. Used for devices providing a TCP/IP interface directly.
|
||
|
||
{% configuration %}
|
||
host:
|
||
description: "IP address or name of your modbus device, e.g., `192.168.1.1`."
|
||
required: true
|
||
type: string
|
||
port:
|
||
description: "Network port for the communication."
|
||
required: true
|
||
type: integer
|
||
|
||
{% endconfiguration %}
|
||
|
||
### Example: typical tcp configuration
|
||
|
||
```yaml
|
||
# Example yaml: typical tcp connection
|
||
modbus:
|
||
- name: modbus_hub
|
||
type: tcp
|
||
host: IP_ADDRESS
|
||
port: 502
|
||
```
|
||
|
||
### Example: full tcp configuration
|
||
|
||
```yaml
|
||
# Example yaml: full tcp connection
|
||
modbus:
|
||
- name: modbus_hub
|
||
type: tcp
|
||
host: IP_ADDRESS
|
||
port: 502
|
||
|
||
delay: 0
|
||
message_wait_milliseconds: 30
|
||
timeout: 5
|
||
```
|
||
|
||
## Configuring a TCP-RTU connection
|
||
|
||
`type: rtuovertcp` is required. Used for devices providing a TCP/IP interface directly.
|
||
|
||
This is typically used, when communicating with a modbus-forwarder, a device that
|
||
has a TCP/IP connection upwards, and one or more serial connections downwards. lets also
|
||
write more here, to see if the error moves.
|
||
|
||
{% configuration %}
|
||
host:
|
||
description: "IP address or name of your modbus device, e.g., `192.168.1.1`."
|
||
required: true
|
||
type: string
|
||
port:
|
||
description: "Network port for the communication."
|
||
required: true
|
||
type: integer
|
||
|
||
{% endconfiguration %}
|
||
|
||
### Example: typical TCP-RTU configuration
|
||
|
||
```yaml
|
||
# Example yaml: typical tcp-rtu connection
|
||
modbus:
|
||
- name: modbus_hub
|
||
type: rtuovertcp
|
||
host: IP_ADDRESS
|
||
port: 502
|
||
```
|
||
|
||
### Example: full TCP-RTU configuration
|
||
|
||
```yaml
|
||
# Example yaml: full tcp-rtu connection
|
||
modbus:
|
||
- name: modbus_hub
|
||
type: rtuovertcp
|
||
host: IP_ADDRESS
|
||
port: 502
|
||
|
||
delay: 0
|
||
message_wait_milliseconds: 30
|
||
timeout: 5
|
||
```
|
||
|
||
## Configuring a UDP connection
|
||
|
||
`type: udp` is required. This is rarely used, and only for very special configurations.
|
||
|
||
{% configuration %}
|
||
host:
|
||
description: "IP address or name of your modbus device, e.g., `192.168.1.1`."
|
||
required: true
|
||
type: string
|
||
port:
|
||
description: "Network port for the communication."
|
||
required: true
|
||
type: integer
|
||
|
||
{% endconfiguration %}
|
||
|
||
### Example: typical udp configuration
|
||
|
||
```yaml
|
||
# Example yaml: typical udp connection
|
||
modbus:
|
||
- name: modbus_hub
|
||
type: udp
|
||
host: IP_ADDRESS
|
||
port: 502
|
||
```
|
||
|
||
### Example: full UDP configuration
|
||
|
||
```yaml
|
||
# Example yaml: full udp connection
|
||
modbus:
|
||
- name: modbus_hub
|
||
type: udp
|
||
host: IP_ADDRESS
|
||
port: 502
|
||
|
||
delay: 0
|
||
message_wait_milliseconds: 30
|
||
timeout: 5
|
||
```
|
||
|
||
## Configuring serial connection
|
||
|
||
`type: serial` is required. This is used for devices providing a serial rs485 interface.
|
||
|
||
The physical interface is typically a USB serial-rs485 converter or an rs232-rs485 connected to a serial port.
|
||
|
||
{% configuration %}
|
||
baudrate:
|
||
description: "Speed of the serial connection, higher speed gives better performance."
|
||
required: true
|
||
type: integer
|
||
bytesize:
|
||
description: "Data size in bits of each byte."
|
||
required: true
|
||
type: list
|
||
keys:
|
||
"5":
|
||
description: "5 bit for data, rarely used."
|
||
"6":
|
||
description: "6 bit for data, rarely used."
|
||
"7":
|
||
description: "7 bit for data, used for very old devices."
|
||
"8":
|
||
description: "8 bit for data, standard."
|
||
method:
|
||
description: "Method of the connection to modbus."
|
||
required: true
|
||
type: list
|
||
keys:
|
||
rtu:
|
||
description: "Binary data transmission preceded by slave id and followed by a crc, standard."
|
||
ascii:
|
||
description: "ASCII data transmission preceded by slave id and followed by a crc, used for few devices."
|
||
parity:
|
||
description: "Parity of the data bytes."
|
||
required: true
|
||
type: list
|
||
keys:
|
||
E:
|
||
description: "Even parity bit."
|
||
O:
|
||
description: "Odd parity bit."
|
||
N:
|
||
description: "No parity bit, standard."
|
||
port:
|
||
description: "Serial port or USB device where your modbus device is connected to your Home Assistant host."
|
||
required: true
|
||
type: string
|
||
stopbits:
|
||
description: "Stopbits of the data bytes."
|
||
required: true
|
||
type: list
|
||
keys:
|
||
'1':
|
||
description: "1 stop bit."
|
||
'2':
|
||
description: "2 stop bits, standard."
|
||
|
||
{% endconfiguration %}
|
||
|
||
### Example: typical serial configuration
|
||
|
||
```yaml
|
||
# Example yaml: typical serial connection
|
||
modbus:
|
||
- name: modbus_hub
|
||
type: serial
|
||
port: /dev/ttyUSB0
|
||
baudrate: 9600
|
||
bytesize: 8
|
||
method: rtu
|
||
parity: E
|
||
stopbits: 1
|
||
```
|
||
|
||
### Example: full serial configuration
|
||
|
||
```yaml
|
||
# Example yaml: full udp connection
|
||
modbus:
|
||
- name: modbus_hub
|
||
type: serial
|
||
port: /dev/ttyUSB0
|
||
baudrate: 9600
|
||
bytesize: 8
|
||
method: rtu
|
||
parity: E
|
||
stopbits: 1
|
||
|
||
delay: 0
|
||
message_wait_milliseconds: 30
|
||
timeout: 5
|
||
```
|
||
|
||
|
||
## Configuring multiple connections
|
||
|
||
Multiple connections can freely mix different communications:
|
||
|
||
```yaml
|
||
# Example yaml: multiple tcp connections
|
||
modbus:
|
||
- name: modbus_hub
|
||
type: tcp
|
||
host: IP_ADDRESS_1
|
||
port: 2020
|
||
|
||
- name: modbus_hub2
|
||
type: tcp
|
||
host: IP_ADDRESS_2
|
||
port: 502
|
||
```
|
||
|
||
|
||
```yaml
|
||
# Example yaml: tcp connection and serial connection
|
||
modbus:
|
||
- name: modbus_hub
|
||
type: tcp
|
||
host: IP_ADDRESS_1
|
||
port: 2020
|
||
|
||
- name: modbus_hub2
|
||
type: serial
|
||
port: /dev/ttyUSB0
|
||
baudrate: 9600
|
||
bytesize: 8
|
||
method: rtu
|
||
parity: E
|
||
stopbits: 1
|
||
```
|
||
|
||
# Configuring modbus entities
|
||
|
||
modbus entities are grouped below each modbus communication entry.
|
||
|
||
All modbus entities have the following parameters:
|
||
|
||
Please refer to [Parameter usage](#parameters-usage-matrix) for conflicting parameters.
|
||
|
||
{% configuration %}
|
||
address:
|
||
description: "Address of coil/register."
|
||
required: true
|
||
type: integer
|
||
name:
|
||
description: "Name of the entity which must be unique within the entity type."
|
||
required: true
|
||
type: string
|
||
scan_interval:
|
||
description: "Update interval in seconds.
|
||
scan_interval = 0 for no polling.
|
||
Entities are read shortly after startup and then according to scan_interval.
|
||
Remark, when restarting HA the last known value is restored."
|
||
required: false
|
||
type: integer
|
||
default: 15
|
||
slave:
|
||
description: "Identical to `device_address`"
|
||
required: false
|
||
type: integer
|
||
default: 0
|
||
device_address:
|
||
description: "Id of the device. Used to address multiple devices on a rs485 bus or devices connected to a modbus repeater."
|
||
required: false
|
||
type: integer
|
||
default: 0
|
||
unique_id:
|
||
description: "ID that uniquely identifies this entity.
|
||
Slaves will be given a unique_id of <<unique_id>>_<<slave_index>>.
|
||
If two enities have the same unique ID, Home Assistant will raise an exception."
|
||
required: false
|
||
type: string
|
||
|
||
{% endconfiguration %}
|
||
|
||
## Example: entities grouping
|
||
|
||
```yaml
|
||
# Example yaml: entities grouping
|
||
modbus:
|
||
- type: tcp
|
||
host: IP_ADDRESS_1
|
||
port: 2020
|
||
name: "modbus_hub"
|
||
binary_sensors:
|
||
- name: binary_sensor1
|
||
address: 100
|
||
climates:
|
||
- name: "Watlow F4T"
|
||
address: 200
|
||
covers:
|
||
- name: Door1
|
||
address: 300
|
||
fans:
|
||
- name: Fan1
|
||
address: 400
|
||
lights:
|
||
- name: light1
|
||
address: 500
|
||
sensors:
|
||
- name: sensor1
|
||
address: 600
|
||
switches:
|
||
- name: Switch1
|
||
address: 700
|
||
```
|
||
|
||
The different types of entities are detailed in the following.
|
||
|
||
## Configuring binary sensor entities
|
||
|
||
The Modbus binary sensor allows you to gather data from coils which as per standard have state ON/OFF.
|
||
|
||
Normally, a register contains 16 coils, giving different addresses depending on the request used.
|
||
|
||
```yaml
|
||
Register 512: Coil 1 - 16
|
||
Register 513: Coil 17 - 32
|
||
```
|
||
|
||
`input_type: coils` would use addresses from 1 through 32, while `input_type: input` would use addresses 512 and 513.
|
||
For that reason, many devices (especially older ones) do not share the coil address space with the register address space,
|
||
and this `input` would read from a different address space than `coil`. The problem is present in devices with
|
||
shared address space and are a frequent cause of problems when configuring entities.
|
||
|
||
Please refer to [Parameter usage](#parameters-usage-matrix) for conflicting parameters.
|
||
|
||
{% configuration %}
|
||
binary_sensors:
|
||
description: "A list of all binary sensors configured for this connection."
|
||
required: false
|
||
type: map
|
||
keys:
|
||
device_class:
|
||
description: "The [type/class](/integrations/binary_sensor/#device-class) to be used for the UI."
|
||
required: false
|
||
type: string
|
||
input_type:
|
||
description: "Type of request `discrete_input`, `coil`, `holding` or `input`"
|
||
required: false
|
||
default: coil
|
||
type: string
|
||
slave_count:
|
||
description: "Identical to `virtual_count`."
|
||
required: false
|
||
type: integer
|
||
virtual_count:
|
||
description: "Generate count+1 binary sensors (master + slaves).
|
||
Addresses are automatically incremented.
|
||
The parameter simplifies configuration and provides a much better performance by not using count+1 requests but a single request."
|
||
required: false
|
||
type: integer
|
||
unique_id:
|
||
description: "ID that uniquely identifies the entity. Slaves will automatically be given a unique_id of <<unique_id>>_<<slave_index>>. If two sensors have the same unique ID, Home Assistant will raise an exception."
|
||
required: false
|
||
type: string
|
||
|
||
{% endconfiguration %}
|
||
|
||
### Example: typical binary sensor configuration
|
||
|
||
```yaml
|
||
# Example yaml: typical binary_sensor
|
||
modbus:
|
||
- name: hub1
|
||
type: tcp
|
||
host: IP_ADDRESS
|
||
port: 502
|
||
binary_sensors:
|
||
- name: my_relay
|
||
address: 100
|
||
slave: 1
|
||
```
|
||
|
||
### Example: full binary sensor configuration
|
||
|
||
```yaml
|
||
# Example yaml: binary_sensor with all options
|
||
modbus:
|
||
- name: hub1
|
||
type: tcp
|
||
host: IP_ADDRESS
|
||
port: 502
|
||
binary_sensors:
|
||
- name: my_relay
|
||
address: 100
|
||
device_class: door
|
||
input_type: coil
|
||
scan_interval: 15
|
||
slave: 1
|
||
slave_count: 0
|
||
unique_id: my_relay
|
||
```
|
||
|
||
### Example: multiple identical binary sensor configuration
|
||
|
||
```yaml
|
||
# Example of 10 identical binary_sensor
|
||
modbus:
|
||
- name: hub1
|
||
type: tcp
|
||
host: IP_ADDRESS
|
||
port: 502
|
||
binary_sensors:
|
||
- name: my_relay
|
||
address: 100
|
||
slave: 1
|
||
slave_count: 10
|
||
unique_id: my_relay
|
||
```
|
||
|
||
This configuration will poll coil addresses 100 to 110 every 15 seconds and update the binary_sensors: `my_relay`
|
||
and `my_relay_1` to `my_relay_10`.
|
||
|
||
The master configuration like device_class are automatically copied to the slaves.
|
||
|
||
## Configuring climate entities
|
||
|
||
The Modbus climate platform allows you to monitor a thermostat or heaters as well as set a target temperature, HVAC mode and fan state.
|
||
|
||
Please refer to [Parameter usage](#parameters-usage-matrix) for conflicting parameters.
|
||
|
||
{% configuration %}
|
||
climates:
|
||
description: "A list of all climate entities in this modbus instance."
|
||
required: false
|
||
type: map
|
||
keys:
|
||
count:
|
||
description: "Number of registers to read.
|
||
**only valid for `data_type: custom` and `data_type: string`**, for other data types count is automatically calculated."
|
||
required: false
|
||
type: integer
|
||
data_type:
|
||
description: "Response representation."
|
||
required: false
|
||
default: int16
|
||
type: list
|
||
keys:
|
||
custom:
|
||
description: "user defined format, `structure:` and `count:` must be configured."
|
||
float16:
|
||
description: "16 bit signed float (1 register holds 1 value)."
|
||
float32:
|
||
description: "32 bit signed float (2 registers holds 1 value)."
|
||
float64:
|
||
description: "64 bit signed float (4 register holds 1 value)."
|
||
int:
|
||
description: "**DEPRECATED** is silently converted to `int16`"
|
||
int16:
|
||
description: "16 bit signed integer (1 register holds 1 value)."
|
||
int32:
|
||
description: "32 bit signed integer (2 registers holds 1 value)."
|
||
int64:
|
||
description: "64 bit signed integer (4 registers holds 1 value)."
|
||
string:
|
||
description: "set of 8 bit characters, `count:` must be configured."
|
||
uint:
|
||
description: "**DEPRECATED** is silently converted to `uint16`"
|
||
uint16:
|
||
description: "16 bit unsigned integer (1 register holds 1 value)."
|
||
uint32:
|
||
description: "32 bit unsigned integer (2 registers holds 1 value)."
|
||
uint64:
|
||
description: "64 bit unsigned integer (4 registers holds 1 value)."
|
||
hvac_mode_register:
|
||
description: "Configuration of register for HVAC mode"
|
||
required: false
|
||
type: map
|
||
keys:
|
||
address:
|
||
description: "Address of HVAC mode register."
|
||
required: true
|
||
type: integer
|
||
write_registers:
|
||
description: "Request type, use `write_registers` if true else `write_register`.
|
||
If more than one value is specified for a specific mode, only the first one is used for writing to the register."
|
||
required: false
|
||
type: boolean
|
||
default: false
|
||
values:
|
||
description: "Mapping between the register values and HVAC modes"
|
||
required: true
|
||
type: map
|
||
keys:
|
||
state_off:
|
||
description: "Value corresponding to HVAC Off mode."
|
||
required: false
|
||
type: [integer, list]
|
||
state_heat:
|
||
description: "Value corresponding to HVAC Heat mode."
|
||
required: false
|
||
type: [integer, list]
|
||
state_cool:
|
||
description: "Value corresponding to HVAC Cool mode."
|
||
required: false
|
||
type: [integer, list]
|
||
state_auto:
|
||
description: "Value corresponding to HVAC Auto mode."
|
||
required: false
|
||
type: [integer, list]
|
||
state_dry:
|
||
description: "Value corresponding to HVAC Dry mode."
|
||
required: false
|
||
type: [integer, list]
|
||
state_fan_only:
|
||
description: "Value corresponding to HVAC Fan only mode."
|
||
required: false
|
||
type: [integer, list]
|
||
state_heat_cool:
|
||
description: "Value corresponding to HVAC Heat/Cool mode."
|
||
required: false
|
||
type: [integer, list]
|
||
fan_mode_register:
|
||
description: "Configuration of register for Fan mode"
|
||
required: false
|
||
type: map
|
||
keys:
|
||
address:
|
||
description: "Address of Fan mode register. (int to call write_register, list of 1 int to call write_registers)"
|
||
required: true
|
||
type: [integer, list]
|
||
values:
|
||
description: "Mapping between the register values and Fan modes
|
||
This is typically used to control one of: Speed, Direction or On/Off state."
|
||
required: true
|
||
type: map
|
||
keys:
|
||
state_fan_on:
|
||
description: "Value corresponding to Fan On mode."
|
||
required: false
|
||
type: integer
|
||
state_fan_off:
|
||
description: "Value corresponding to Fan Off mode."
|
||
required: false
|
||
type: integer
|
||
state_fan_low:
|
||
description: "Value corresponding to Fan Low mode."
|
||
required: false
|
||
type: integer
|
||
state_fan_medium:
|
||
description: "Value corresponding to Fan Medium mode."
|
||
required: false
|
||
type: integer
|
||
state_fan_high:
|
||
description: "Value corresponding to Fan High mode."
|
||
required: false
|
||
type: integer
|
||
state_fan_auto:
|
||
description: "Value corresponding to Fan Auto mode."
|
||
required: false
|
||
type: integer
|
||
state_fan_top:
|
||
description: "Value corresponding to Fan Top mode."
|
||
required: false
|
||
type: integer
|
||
state_fan_middle:
|
||
description: "Value corresponding to Fan Middle mode."
|
||
required: false
|
||
type: integer
|
||
state_fan_focus:
|
||
description: "Value corresponding to Fan Focus mode."
|
||
required: false
|
||
type: integer
|
||
state_fan_diffuse:
|
||
description: "Value corresponding to Fan Diffuse mode."
|
||
required: false
|
||
type: integer
|
||
hvac_onoff_register:
|
||
description: "Address of On/Off state.
|
||
When zero is read from this register, the HVAC state is set to Off, otherwise the `hvac_mode_register`
|
||
dictates the state of the HVAC. If no such register is defined, it defaults to Auto.
|
||
When the HVAC mode is set to Off, the value 0 is written to the register, otherwise the
|
||
value 1 is written."
|
||
required: false
|
||
type: integer
|
||
input_type:
|
||
description: Modbus register type for current temperature.
|
||
required: false
|
||
default: holding
|
||
type: list
|
||
keys:
|
||
holding:
|
||
description: "Holding register."
|
||
input:
|
||
description: "Input register."
|
||
max_temp:
|
||
description: "Maximum setpoint temperature."
|
||
required: false
|
||
type: integer
|
||
default: 35
|
||
min_temp:
|
||
description: "Minimum setpoint temperature."
|
||
required: false
|
||
type: integer
|
||
default: 5
|
||
offset:
|
||
description: "Final offset (output = scale * value + offset)."
|
||
required: false
|
||
type: float
|
||
default: 0
|
||
precision:
|
||
description: "Number of valid decimals."
|
||
required: false
|
||
type: integer
|
||
default: 0
|
||
scale:
|
||
description: "Scale factor (output = scale * value + offset)."
|
||
required: false
|
||
type: float
|
||
default: 1
|
||
structure:
|
||
description: "If `data_type: custom` is specified a double-quoted Python struct is expected,
|
||
to format the string to unpack the value. See Python documentation for details.
|
||
Example: `>i`."
|
||
required: false
|
||
type: string
|
||
default: ">f"
|
||
swap:
|
||
description: "Swap the order of bytes/words, **not valid with `custom` and `datatype: string`**"
|
||
required: false
|
||
default: none
|
||
type: list
|
||
keys:
|
||
byte:
|
||
description: "Swap bytes AB -> BA."
|
||
word:
|
||
description: "Swap word ABCD -> CDAB, **not valid with data types: `int16`, `uint16`**"
|
||
word_byte:
|
||
description: "Swap word ABCD -> DCBA, **not valid with data types: `int16`, `uint16`**"
|
||
target_temp_register:
|
||
description: "Register address for target temperature (Setpoint)."
|
||
required: true
|
||
type: integer
|
||
target_temp_write_registers:
|
||
description: "If `true` use `write_registers` for target temperature."
|
||
required: false
|
||
type: boolean
|
||
default: false
|
||
temp_step:
|
||
description: "Step size target temperature."
|
||
required: false
|
||
type: float
|
||
default: 0.5
|
||
temperature_unit:
|
||
description: "Temperature unit reported by current_temp_register. C or F."
|
||
required: false
|
||
default: C
|
||
type: list
|
||
keys:
|
||
C:
|
||
description: "Celsius"
|
||
F:
|
||
description: "Fahrenheit"
|
||
write_registers:
|
||
description: "Request type, use `write_registers` if true else `write_register`."
|
||
required: false
|
||
type: boolean
|
||
default: false
|
||
|
||
{% endconfiguration %}
|
||
|
||
### Example: climate configuration
|
||
|
||
```yaml
|
||
# Example configuration.yaml entry
|
||
modbus:
|
||
- name: hub1
|
||
type: tcp
|
||
host: IP_ADDRESS
|
||
port: 502
|
||
climates:
|
||
- name: "Watlow F4T"
|
||
address: 27586
|
||
input_type: holding
|
||
count: 1
|
||
data_type: custom
|
||
max_temp: 35
|
||
min_temp: 15
|
||
offset: 0
|
||
precision: 1
|
||
scale: 0.1
|
||
max_temp: 30
|
||
structure: ">f"
|
||
target_temp_register: 2782
|
||
target_temp_write_registers: true
|
||
temp_step: 1
|
||
temperature_unit: C
|
||
```
|
||
|
||
## Configuring cover entities
|
||
|
||
The `modbus` cover platform allows you to control covers (such as blinds, a roller shutter, or a garage door).
|
||
|
||
At the moment, platform cover support the opening and closing of a cover. You can control your covers either using coils or holding registers.
|
||
|
||
Cover that uses `input_type: coil` is not able to determine intermediary states such as opening and closing. Coil stores only two states — "0" means cover closed, and "1" implies cover open. To allow detecting intermediary states, there is an optional `status_register` attribute. It will enable you to write your command (e.g., to open a cover) into a coil, and read current cover status back through the register. Additionally, you can specify values for `state_open`, `state_opening`, `state_closed`, and `state_closing` attributes. These will be matched with the value read from the `status_register`.
|
||
|
||
If your cover uses `input_type: holding` (default) to send commands, it can also read the intermediary states. To adjust which value represents what state, you can fine-tune the optional state attributes, like `state_open`. These optional state values are also used for specifying values written into the register. If you specify an optional status_register attribute, cover states will be read from status_register instead of the register used for sending commands.
|
||
|
||
Please refer to [Parameter usage](#parameters-usage-matrix) for conflicting parameters.
|
||
|
||
{% configuration %}
|
||
covers:
|
||
description: "A list of all cover entities configured for this connection."
|
||
required: true
|
||
type: map
|
||
keys:
|
||
device_class:
|
||
description: "The [type/class](/integrations/cover/#device-class) of the cover to set the icon in the frontend."
|
||
required: false
|
||
type: device_class
|
||
default: None
|
||
input_type:
|
||
description: "Cover register type."
|
||
default: holding
|
||
required: false
|
||
type: list
|
||
keys:
|
||
holding:
|
||
description: "Holding register."
|
||
input:
|
||
description: "Input register."
|
||
state_open:
|
||
description: "A value in `status_register` or `register` representing an open cover.
|
||
If your configuration uses the `register` attribute, this value will be written into the holding register to open the cover."
|
||
required: false
|
||
default: 1
|
||
type: integer
|
||
state_closed:
|
||
description: "A value in `status_register` or `register` representing a closed cover.
|
||
If your configuration uses the `register` attribute, this value will be written into the holding register to close the cover."
|
||
required: false
|
||
default: 0
|
||
type: integer
|
||
state_opening:
|
||
description: "A value in `status_register` or `register` representing an opening cover.
|
||
Note that this state should be also supported on your connected Modbus cover.
|
||
If it won't report the state, this state won't be detected."
|
||
required: false
|
||
default: 2
|
||
type: integer
|
||
state_closing:
|
||
description: "A value in `status_register` or `register` representing a closing cover.
|
||
Note that this state should be also supported on your connected Modbus cover.
|
||
If it will not report the state, this state won't be detected."
|
||
required: false
|
||
default: 3
|
||
type: integer
|
||
status_register:
|
||
description: "Address of register, from which all the cover states will be read.
|
||
If you specified `register` attribute, and not `status_register` attribute,
|
||
your main register will also be used as a status register."
|
||
required: false
|
||
type: integer
|
||
status_register_type:
|
||
description: Cover status register type (holding, input), default holding.
|
||
required: false
|
||
type: list
|
||
keys:
|
||
holding:
|
||
description: "Holding register."
|
||
input:
|
||
description: "Input register."
|
||
{% endconfiguration %}
|
||
|
||
### Example: Modbus cover
|
||
|
||
```yaml
|
||
# Example configuration.yaml entry
|
||
modbus:
|
||
- name: hub1
|
||
type: tcp
|
||
host: IP_ADDRESS
|
||
port: 502
|
||
covers:
|
||
- name: Door1
|
||
device_class: door
|
||
input_type: coil
|
||
address: 117
|
||
state_open: 1
|
||
state_opening: 2
|
||
state_closed: 0
|
||
state_closing: 3
|
||
status_register: 119
|
||
status_register_type: holding
|
||
- name: "Door2"
|
||
address: 118
|
||
```
|
||
|
||
|
||
### Example: Modbus cover controlled by a coil
|
||
|
||
This example shows a configuration for a Modbus cover controlled using a coil. Intermediary states like opening/closing are not supported. The cover state is polled from Modbus every 10 seconds.
|
||
|
||
```yaml
|
||
modbus:
|
||
- name: hub1
|
||
type: tcp
|
||
host: IP_ADDRESS
|
||
port: 502
|
||
covers:
|
||
- name: Door1
|
||
slave: 1
|
||
coil: 1
|
||
device_class: door
|
||
scan_interval: 10
|
||
- name: Door2
|
||
slave: 2
|
||
coil: 2
|
||
device_class: door
|
||
scan_interval: 10
|
||
```
|
||
|
||
### Example: Modbus cover controlled by a coil, its state is read from the register
|
||
|
||
This example shows a configuration for a Modbus cover controlled using a coil. Actual cover state is read from the `status_register`. We've also specified register values to match with the states open/opening/closed/closing. The cover state is polled from Modbus every 10 seconds.
|
||
|
||
```yaml
|
||
modbus:
|
||
- name: hub1
|
||
type: tcp
|
||
host: IP_ADDRESS
|
||
port: 502
|
||
covers:
|
||
- name: Door1
|
||
slave: 1
|
||
device_class: door
|
||
scan_interval: 10
|
||
coil: 1
|
||
status_register: 1
|
||
status_register_type: input
|
||
state_opening: 1
|
||
state_open: 2
|
||
state_closing: 3
|
||
state_closed: 4
|
||
```
|
||
|
||
### Example: Modbus cover controlled by a holding register
|
||
|
||
This example shows a configuration for a Modbus cover controlled using a holding register, from which we also read current cover state. We've also specified register values to match with the states open/opening/closed/closing. The cover state is polled from Modbus every 10 seconds.
|
||
|
||
```yaml
|
||
modbus:
|
||
- name: hub1
|
||
type: tcp
|
||
host: IP_ADDRESS
|
||
port: 502
|
||
covers:
|
||
- name: Door1
|
||
slave: 1
|
||
device_class: door
|
||
scan_interval: 10
|
||
register: 1
|
||
state_opening: 1
|
||
state_open: 2
|
||
state_closing: 3
|
||
state_closed: 4
|
||
```
|
||
|
||
### Example: Modbus cover controlled by a holding register, its state is read from the status register
|
||
|
||
This example shows a configuration for a Modbus cover controlled using a holding register. However, cover state is read from a `status_register`. In this case, we've specified only values for `state_open` and `state_closed`, for the rest, default values are used. The cover state is polled from Modbus every 10 seconds.
|
||
|
||
```yaml
|
||
modbus:
|
||
- name: hub1
|
||
type: tcp
|
||
host: IP_ADDRESS
|
||
port: 502
|
||
|
||
covers:
|
||
- name: Door1
|
||
slave: 1
|
||
device_class: door
|
||
scan_interval: 10
|
||
register: 1
|
||
status_register: 2
|
||
register_type: holding
|
||
state_open: 1
|
||
state_closed: 0
|
||
```
|
||
|
||
## Configuring fan entities
|
||
|
||
The `modbus` fan platform allows you to control [Modbus](http://www.modbus.org/) coils or registers.
|
||
|
||
Please refer to [Parameter usage](#parameters-usage-matrix) for conflicting parameters.
|
||
|
||
{% configuration %}
|
||
fans:
|
||
description: "A list of all fan entities in this modbus instance."
|
||
required: true
|
||
type: map
|
||
keys:
|
||
command_on:
|
||
description: "Value to write to turn on the fan."
|
||
required: false
|
||
default: 0x01
|
||
type: integer
|
||
command_off:
|
||
description: "Value to write to turn off the fan."
|
||
required: false
|
||
default: 0x00
|
||
type: integer
|
||
write_type:
|
||
description: Type of write request.
|
||
required: false
|
||
default: holding
|
||
type: list
|
||
keys:
|
||
holding:
|
||
description: "write_register is called."
|
||
holdings:
|
||
description: "write_registers is called."
|
||
coil:
|
||
description: "write_coil is called."
|
||
coils:
|
||
description: "write_coils is called."
|
||
verify:
|
||
description: "Read from Modbus device to verify fan.
|
||
If used without attributes, it uses the toggle register configuration.
|
||
If omitted, no verification is done, but the state of the fan is set with each toggle."
|
||
required: false
|
||
type: map
|
||
keys:
|
||
address:
|
||
description: "Address to read from."
|
||
required: false
|
||
default: write address
|
||
type: integer
|
||
delay:
|
||
description: "Delay between write and verify."
|
||
required: false
|
||
default: 0
|
||
type: integer
|
||
input_type:
|
||
description: Type of address.
|
||
required: false
|
||
default: same as `write_type`
|
||
type: list
|
||
keys:
|
||
coil:
|
||
description: "Coil (1bit relay)."
|
||
discrete:
|
||
description: "Discret input (1bit relay)."
|
||
holding:
|
||
description: "Holding register."
|
||
input:
|
||
description: "Input register."
|
||
state_on:
|
||
description: "Value when the fan is on."
|
||
required: false
|
||
default: same as `command_on`
|
||
type: integer
|
||
state_off:
|
||
description: "Value when the fan is off."
|
||
required: false
|
||
default: same as `command_off`
|
||
type: integer
|
||
{% endconfiguration %}
|
||
|
||
### Example: fan configuration
|
||
|
||
```yaml
|
||
# Example configuration.yaml entry
|
||
modbus:
|
||
- type: tcp
|
||
host: IP_ADDRESS
|
||
port: 502
|
||
fans:
|
||
- name: "Fan1"
|
||
address: 13
|
||
write_type: coil
|
||
- name: "Fan2"
|
||
slave: 2
|
||
address: 14
|
||
write_type: coil
|
||
verify:
|
||
- name: "Register1"
|
||
address: 11
|
||
command_on: 1
|
||
command_off: 0
|
||
verify:
|
||
input_type: holding
|
||
address: 127
|
||
state_on: 25
|
||
state_off: 1
|
||
```
|
||
|
||
## Configuring light entities
|
||
|
||
The `modbus` light platform allows you to control [Modbus](http://www.modbus.org/) coils or registers.
|
||
|
||
Please refer to [Parameter usage](#parameters-usage-matrix) for conflicting parameters.
|
||
|
||
{% configuration %}
|
||
lights:
|
||
description: "A list of all light entities in this modbus instance."
|
||
required: true
|
||
type: map
|
||
keys:
|
||
command_on:
|
||
description: "Value to write to turn on the light."
|
||
required: false
|
||
default: 0x01
|
||
type: integer
|
||
command_off:
|
||
description: "Value to write to turn off the light."
|
||
required: false
|
||
default: 0x00
|
||
type: integer
|
||
write_type:
|
||
description: "Type of write request."
|
||
required: false
|
||
default: holding
|
||
type: list
|
||
keys:
|
||
holding:
|
||
description: "write_register is called."
|
||
holdings:
|
||
description: "write_registers is called."
|
||
coil:
|
||
description: "write_coil is called."
|
||
coils:
|
||
description: "write_coils is called."
|
||
verify:
|
||
description: "Read from Modbus device to verify the light.
|
||
If used without attributes, it uses the toggle register configuration.
|
||
If omitted no verification, is done, but the state of the light is set with each toggle."
|
||
required: false
|
||
type: map
|
||
keys:
|
||
address:
|
||
description: "Address to read from."
|
||
required: false
|
||
default: "Same as `address`"
|
||
type: integer
|
||
delay:
|
||
description: delay between write and verify.
|
||
required: false
|
||
default: 0
|
||
type: integer
|
||
input_type:
|
||
description: Type of address (holding/coil/discrete/input).
|
||
required: false
|
||
default: "Same as `write_type`"
|
||
type: list
|
||
keys:
|
||
coil:
|
||
description: "Coil (1bit relay)."
|
||
discrete:
|
||
description: "Discrete inout (1bit relay)."
|
||
holding:
|
||
description: "Holding register."
|
||
input:
|
||
description: "Input register."
|
||
state_on:
|
||
description: "Value when the light is on."
|
||
required: false
|
||
default: "Same as `command_on`"
|
||
type: integer
|
||
state_off:
|
||
description: "Value when the light is off."
|
||
required: false
|
||
default: "Same as `command_off`"
|
||
type: integer
|
||
|
||
{% endconfiguration %}
|
||
|
||
### Example: light configuration
|
||
|
||
```yaml
|
||
# Example configuration.yaml entry
|
||
modbus:
|
||
- type: tcp
|
||
host: IP_ADDRESS
|
||
port: 502
|
||
lights:
|
||
- name: "light1"
|
||
address: 13
|
||
write_type: coil
|
||
- name: "light2"
|
||
slave: 2
|
||
address: 14
|
||
write_type: coil
|
||
verify:
|
||
- name: "Register1"
|
||
address: 11
|
||
command_on: 1
|
||
command_off: 0
|
||
verify:
|
||
input_type: holding
|
||
address: 127
|
||
state_on: 25
|
||
state_off: 1
|
||
```
|
||
|
||
## Configuring sensor entities
|
||
|
||
The `modbus` sensor allows you to gather data from [Modbus](http://www.modbus.org/) registers.
|
||
|
||
Please refer to [Parameter usage](#parameters-usage-matrix) for conflicting parameters.
|
||
|
||
{% configuration %}
|
||
sensors:
|
||
description: "A list of all sensors in this modbus instance."
|
||
required: true
|
||
type: map
|
||
keys:
|
||
count:
|
||
description: "Number of registers to read.
|
||
**only valid for `data_type: custom` and `data_type: string`**, for other data types count is automatically calculated."
|
||
required: false
|
||
type: integer
|
||
data_type:
|
||
description: "Response representation."
|
||
required: false
|
||
default: int16
|
||
type: list
|
||
keys:
|
||
custom:
|
||
description: "user defined format, `structure:` and `count:` must be configured."
|
||
float16:
|
||
description: "16 bit signed float (1 register holds 1 value)."
|
||
float32:
|
||
description: "32 bit signed float (2 registers holds 1 value)."
|
||
float64:
|
||
description: "64 bit signed float (4 register holds 1 value)."
|
||
int:
|
||
description: "**DEPRECATED** is silently converted to `int16`"
|
||
int16:
|
||
description: "16 bit signed integer (1 register holds 1 value)."
|
||
int32:
|
||
description: "32 bit signed integer (2 registers holds 1 value)."
|
||
int64:
|
||
description: "64 bit signed integer (4 registers holds 1 value)."
|
||
string:
|
||
description: "set of 8 bit characters, `count:` must be configured."
|
||
uint:
|
||
description: "**DEPRECATED** is silently converted to `uint16`"
|
||
uint16:
|
||
description: "16 bit unsigned integer (1 register holds 1 value)."
|
||
uint32:
|
||
description: "32 bit unsigned integer (2 registers holds 1 value)."
|
||
uint64:
|
||
description: "64 bit unsigned integer (4 registers holds 1 value)."
|
||
device_class:
|
||
description: "The [type/class](/integrations/sensor/#device-class) of the sensor to set the icon in the frontend."
|
||
required: false
|
||
type: device_class
|
||
default: None
|
||
input_type:
|
||
description: "Modbus register type for sensor."
|
||
required: false
|
||
default: holding
|
||
type: list
|
||
keys:
|
||
holding:
|
||
description: "Holding register."
|
||
input:
|
||
description: "Input register."
|
||
min_value:
|
||
description: "The minimum allowed value of a sensor. If value < min_value --> min_value. Can be float or integer"
|
||
required: false
|
||
type: float
|
||
max_value:
|
||
description: "The maximum allowed value of a sensor. If value > max_value --> max_value. Can be float or integer"
|
||
required: false
|
||
type: float
|
||
nan_value:
|
||
description: If a Modbus sensor has a defined NaN value, this value can be set as a hex string starting with `0x` containing one or more bytes (for example, `0xFFFF` or `0x80000000`) or provided as an integer directly. If triggered, the sensor becomes `unavailable`. Please note that the hex to int conversion for `nan_value` does currently not obey home-assistants Modbus encoding using the `data_type`, `structure`, or `swap` arguments.
|
||
required: false
|
||
type: string
|
||
zero_suppress:
|
||
description: Suppress values close to zero. If -zero_suppress <= value <= +zero_suppress --> 0. Can be float or integer
|
||
required: false
|
||
type: float
|
||
offset:
|
||
description: "Final offset (output = scale * value + offset)."
|
||
required: false
|
||
type: float
|
||
default: 0
|
||
precision:
|
||
description: "Number of valid decimals."
|
||
required: false
|
||
type: integer
|
||
default: 0
|
||
scale:
|
||
description: "Scale factor (output = scale * value + offset)."
|
||
required: false
|
||
type: float
|
||
default: 1
|
||
slave_count:
|
||
description: "Identical to `virtual_count`."
|
||
required: false
|
||
type: integer
|
||
virtual_count:
|
||
description: "Generates x+1 sensors (master + slaves), allowing read of multiple registers with a single read messsage."
|
||
required: false
|
||
type: integer
|
||
state_class:
|
||
description: "The [state_class](https://developers.home-assistant.io/docs/core/entity/sensor#available-state-classes) of the sensor."
|
||
required: false
|
||
type: string
|
||
structure:
|
||
description: "If `data_type: custom` is specified a double-quoted Python struct is expected,
|
||
to format the string to unpack the value. See Python documentation for details.
|
||
Example: `>i`."
|
||
required: false
|
||
type: string
|
||
default: ">f"
|
||
slave_count:
|
||
description: "Identical to `virtual_count`."
|
||
required: false
|
||
type: integer
|
||
virtual_count:
|
||
description: Generates x-1 slave sensors, allowing read of multiple registers with a single read message.
|
||
required: false
|
||
type: integer
|
||
swap:
|
||
description: "Swap the order of bytes/words, **not valid with `custom` and `datatype: string`**"
|
||
required: false
|
||
default: none
|
||
type: list
|
||
keys:
|
||
byte:
|
||
description: "Swap bytes AB -> BA."
|
||
word:
|
||
description: "Swap word ABCD -> CDAB, **not valid with data types: `int16`, `uint16`**"
|
||
word_byte:
|
||
description: "Swap word ABCD -> DCBA, **not valid with data types: `int16`, `uint16`**"
|
||
unit_of_measurement:
|
||
description: "Unit to attach to value."
|
||
required: false
|
||
type: string
|
||
zero_suppress:
|
||
description: "Suppress values close to zero. If -zero_suppress <= value <= +zero_suppress --> 0. Can be float or integer"
|
||
required: false
|
||
type: float
|
||
{% endconfiguration %}
|
||
|
||
<div class='note'>
|
||
|
||
If you specify scale or offset as floating point values, double precision floating point arithmetic will be used to calculate final value. This can cause loss of precision for values that are larger than 2^53.
|
||
|
||
</div>
|
||
|
||
### Example: sensor configuration
|
||
|
||
```yaml
|
||
# Example configuration.yaml entry
|
||
modbus:
|
||
- name: hub1
|
||
type: tcp
|
||
host: IP_ADDRESS
|
||
port: 502
|
||
sensors:
|
||
- name: Sensor1
|
||
unit_of_measurement: °C
|
||
slave: 1
|
||
address: 100
|
||
- name: Sensor2
|
||
unit_of_measurement: mg
|
||
address: 110
|
||
count: 2
|
||
- name: Sensor3
|
||
unit_of_measurement: °C
|
||
slave: 1
|
||
address: 120
|
||
input_type: input
|
||
data_type: float
|
||
scale: 0.01
|
||
offset: -273.16
|
||
precision: 2
|
||
```
|
||
|
||
|
||
### Example: sensor full configuration
|
||
|
||
Example temperature sensor with a default scan interval:
|
||
|
||
```yaml
|
||
modbus:
|
||
- name: hub1
|
||
type: tcp
|
||
host: IP_ADDRESS
|
||
port: 502
|
||
sensors:
|
||
- name: Room_1
|
||
slave: 10
|
||
address: 0
|
||
input_type: holding
|
||
unit_of_measurement: °C
|
||
state_class: measurement
|
||
count: 1
|
||
scale: 0.1
|
||
offset: 0
|
||
precision: 1
|
||
data_type: integer
|
||
```
|
||
|
||
## Configuring switch entities
|
||
|
||
The `modbus` switch platform allows you to control [Modbus](http://www.modbus.org/) coils or registers.
|
||
|
||
Please refer to [Parameter usage](#parameters-usage-matrix) for conflicting parameters.
|
||
|
||
{% configuration %}
|
||
switches:
|
||
description: "A list of all switches in this modbus instance."
|
||
required: true
|
||
type: map
|
||
keys:
|
||
command_on:
|
||
description: "Value to write to turn on the switch."
|
||
required: false
|
||
default: 0x01
|
||
type: integer
|
||
command_off:
|
||
description: "Value to write to turn off the switch."
|
||
required: false
|
||
default: 0x00
|
||
type: integer
|
||
write_type:
|
||
description: Type of write request.
|
||
required: false
|
||
default: holding
|
||
type: list
|
||
keys:
|
||
holding:
|
||
description: "write_register is called."
|
||
holdings:
|
||
description: "write_registers is called."
|
||
coil:
|
||
description: "write_coil is called."
|
||
coils:
|
||
description: "write_coils is called."
|
||
verify:
|
||
description: "Read from Modbus device to verify fan.
|
||
If used without attributes, it uses the toggle register configuration.
|
||
If omitted, no verification is done, but the state of the fan is set with each toggle."
|
||
required: false
|
||
type: map
|
||
keys:
|
||
address:
|
||
description: "Address to read from."
|
||
required: false
|
||
default: "Same as `write address`"
|
||
type: integer
|
||
delay:
|
||
description: "Delay between write and verify."
|
||
required: false
|
||
default: 0
|
||
type: integer
|
||
input_type:
|
||
description: Type of address.
|
||
required: false
|
||
default: same as `write_type`
|
||
type: list
|
||
keys:
|
||
coil:
|
||
description: "Coil (1bit relay)."
|
||
discrete:
|
||
description: "Discret input (1bit relay)."
|
||
holding:
|
||
description: "Holding register."
|
||
input:
|
||
description: "Input register."
|
||
state_on:
|
||
description: "Value when switch is on."
|
||
required: false
|
||
default: "Same as `command_on`"
|
||
type: integer
|
||
state_off:
|
||
description: "Value when switch is off."
|
||
required: false
|
||
default: "Same as `command_off`"
|
||
type: integer
|
||
|
||
{% endconfiguration %}
|
||
|
||
### Example: switch configuration
|
||
|
||
```yaml
|
||
# Example configuration.yaml entry
|
||
modbus:
|
||
- type: tcp
|
||
host: IP_ADDRESS
|
||
port: 502
|
||
switches:
|
||
- name: Switch1
|
||
address: 13
|
||
write_type: coil
|
||
- name: Switch2
|
||
slave: 2
|
||
address: 14
|
||
write_type: coil
|
||
verify:
|
||
- name: Register1
|
||
address: 11
|
||
command_on: 1
|
||
command_off: 0
|
||
verify:
|
||
input_type: holding
|
||
address: 127
|
||
state_on: 25
|
||
state_off: 1
|
||
```
|
||
|
||
|
||
### Example: switch full configuration
|
||
|
||
```yaml
|
||
# Example configuration.yaml entry
|
||
modbus:
|
||
- type: tcp
|
||
host: IP_ADDRESS
|
||
port: 502
|
||
switches:
|
||
- name: Switch1
|
||
address: 13
|
||
write_type: coil
|
||
- name: Switch2
|
||
slave: 2
|
||
address: 14
|
||
write_type: coil
|
||
verify:
|
||
- name: Register1
|
||
address: 11
|
||
command_on: 1
|
||
command_off: 0
|
||
verify:
|
||
input_type: holding
|
||
address: 127
|
||
state_on: 25
|
||
state_off: 1
|
||
```
|
||
|
||
## Parameters usage matrix
|
||
|
||
Some parameters exclude other parameters, the following tables show what can be combined:
|
||
|
||
| Datatype: | custom | string | *16 | *32 | *64 |
|
||
| --------------- | ------ | ------ | --- | --- | --- |
|
||
| count | Yes | Yes | No | No | No |
|
||
| structure | Yes | No | No | No | No |
|
||
| slave_count | No | No | Yes | Yes | Yes |
|
||
| virtual_count | No | No | Yes | Yes | Yes |
|
||
| swap: byte | No | No | Yes | Yes | Yes |
|
||
| swap: word | No | No | No | Yes | Yes |
|
||
| swap: word_byte | No | No | No | Yes | Yes |
|
||
|
||
|
||
# modbus services
|
||
|
||
The modbus integration provides two generic write services in addition to the platform-specific services.
|
||
|
||
| Service | Description |
|
||
| --------------------- | --------------------------- |
|
||
| modbus.write_register | Write register or registers |
|
||
| modbus.write_coil | Write coil or coils |
|
||
|
||
Description:
|
||
|
||
| Attribute | Description |
|
||
| --------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
|
||
| hub | Hub name (defaults to 'modbus_hub' when omitted) |
|
||
| slave | Slave address (0-255) |
|
||
| address | Address of the Register (e.g. 138) |
|
||
| value | (write_register) A single value or an array of 16-bit values. Single value will call modbus function code 0x06. Array will call modbus function code 0x10. Values might need reverse ordering. E.g., to set 0x0004 you might need to set `[4,0]`, this depend on the byte order of your CPU |
|
||
| state | (write_coil) A single boolean or an array of booleans. Single boolean will call modbus function code 0x05. Array will call modbus function code 0x0F |
|
||
|
||
The modbus integration also provides communication stop/restart services. These services will not do any reconfiguring, but simply stop/start the modbus communication layer.
|
||
|
||
| Service | Description |
|
||
| -------------- | --------------------------------------------- |
|
||
| modbus.stop | Stop communication |
|
||
| modbus.restart | Restart communication (Stop first if running) |
|
||
|
||
Description:
|
||
|
||
| Attribute | Description |
|
||
| --------- | ------------------------------------------------ |
|
||
| hub | Hub name (defaults to 'modbus_hub' when omitted) |
|
||
|
||
## Example: writing a float32 type register
|
||
|
||
To write a float32 datatype register use network format like `10.0` == `0x41200000` (network order float hexadecimal).
|
||
|
||
```yaml
|
||
service: modbus.write_register
|
||
data:
|
||
address: <target register address>
|
||
slave: <target slave address>
|
||
hub: <hub name>
|
||
value: [0x4120, 0x0000]
|
||
```
|
||
|
||
## Service `modbus.set-temperature`
|
||
|
||
| Service | Description |
|
||
| --------------- | --------------------------------------------------------------------------------------------------------------------------------------------- |
|
||
| set_temperature | Set temperature. Requires `value` to be passed in, which is the desired target temperature. `value` should be in the same type as `data_type` |
|
||
|
||
## Service `modbus.set_hvac_mode`
|
||
|
||
| Service | Description |
|
||
| ------------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
|
||
| set_hvac_mode | Set HVAC mode. Requires `value` to be passed in, which is the desired mode. `value` should be a valid HVAC mode. A mapping between the desired state and the value to be written to the HVAC mode register must exist. Calling this service will also set the On/Off register to an appropriate value, if such a register is defined. |
|
||
|
||
|
||
# Opening an issue
|
||
|
||
When opening an issue, please add your current configuration (or a scaled down version), with at least:
|
||
|
||
- the modbus configuration lines
|
||
- the entity (sensor, etc.) lines
|
||
|
||
In order for the developers better to identify the problem, please add the
|
||
following lines to configuration.yaml:
|
||
|
||
```yaml
|
||
logger:
|
||
default: warning
|
||
logs:
|
||
homeassistant.components.modbus: debug
|
||
pymodbus: debug
|
||
```
|
||
|
||
and restart Home Assistant, reproduce the problem, and include the log in the issue.
|
||
|
||
# Building on top of modbus
|
||
|
||
The only recommended way is to inherit the entities needed.
|