2.3 KiB

title, description, ha_category, ha_release, ha_iot_class, ha_codeowners, ha_domain, ha_platforms, ha_integration_type, ha_config_flow
title description ha_category ha_release ha_iot_class ha_codeowners ha_domain ha_platforms ha_integration_type ha_config_flow
Intergas InComfort/Intouch Lan2RF gateway Instructions on how to integrate an Intergas Lan2RF gateway with Home Assistant.
Binary sensor
Climate
Sensor
Water heater
0.93 Local Polling
@jbouwh
incomfort
binary_sensor
climate
sensor
water_heater
integration true

The incomfort {% term integration %} links Home Assistant with your Intergas Lan2RF gateway, including the boiler and any room thermostats attached to it.

It uses the incomfort client library.

Boiler

The boiler is represented as a Water heater device. It will report the boiler's state and current_temperature. The gateway does not expose any means to directly control the boiler or change its configuration.

Note that the current_temperature will switch between the CV (circulating volume) and Tap temperatures according to the current operating mode of the boiler. If the boiler is neither pumping nor tapping, it will be reported as the higher of the two.

In addition, there is a Sensor for each of CV pressure, CV temperature, and Tap temperature, and a Binary sensor that will be on if there is a fault with the boiler (the fault code will be a state attribute).

Rooms

Any room thermostats (there can be 0, 1 or 2) are represented as Climate devices. They will report the thermostat's temperature (setpoint, target temperature) and current_temperature and the setpoint can be changed.

{% include integrations/config_flow.md %}

The hub does not have to be in the same network as HA, but must be reachable via port 80/HTTP.

Automation

To send an alert if the CV pressure is too low or too high, consider the following example:

{% raw %}

- alias: "Low CV Pressure Alert"
  triggers:
    - trigger: numeric_state
      entity_id: sensor.cv_pressure
      below: 1.0
  actions:
    - action: notify.pushbullet_notifier
      data:
        title: "Warning: Low CH Pressure"
        message: >-
          {{ trigger.to_state.attributes.friendly_name }}
          is low, {{ trigger.to_state.state }} bar.

{% endraw %}

Other properties are available via each device's attributes.