APsystems |
Control and monitor your APsystems EZ1 microinverters locally without the cloud |
Local Polling |
true |
2024.6 |
|
apsystems |
binary_sensor |
number |
sensor |
switch |
|
device |
@mawoka-myblock |
@SonnenladenGmbH |
|
The APsystems {% term integration %} allows you to read the data from your APsystems EZ1 microinverter. It also allows you to set the output limit to anything above 30 watts.
Sensors
Numerical sensors
Sensor ID |
Unit |
Description |
total_power |
W |
Total current output of the inverter |
lifetime_production_p1 |
kWh |
Lifetime production of first input |
lifetime_production_p2 |
kWh |
Lifetime production of second input |
lifetime_production |
kWh |
Lifetime production of both inputs combined |
total_power_p1 |
W |
Current input on first input |
total_power_p2 |
W |
Current input on second input |
today_production |
kWh |
Today's production of both inputs combined |
today_production_p1 |
kWh |
Today's production of first input |
today_production_p2 |
kWh |
Today's production of second input |
Binary sensors
Sensor ID |
Description |
off_grid_status |
On when the inverter is not connected to the power grid |
dc_1_short_circuit_error_status |
Short circuit detected on first input |
dc_2_short_circuit_error_status |
Short circuit detected on second input |
output_fault_status |
Output because of any error deactivated |
Settings
Setting ID |
Type |
Description |
inverter_status |
switch |
Enables or disables the inverter's output |
output_limit |
number |
Sets the max output of the inverter |
Prerequisites
Make sure the local API is activated and set to Continuously. For that, connect to the inverter via Bluetooth using the app and go to Settings > Local Mode, set the switch Enable Local Mode to on and make sure to set this to Continuously.
{% include integrations/config_flow.md %}