My KNX device has a "start" (down/up) and a "stop" group address. It works perfectly if I enter the "start" group address in "move_long_address" and "stop" in "move_short_address". However, I only found out because I found issue #10624.
50 lines
2.1 KiB
Markdown
50 lines
2.1 KiB
Markdown
---
|
|
layout: page
|
|
title: "KNX Cover"
|
|
description: "Instructions on how to integrate KNX covers with Home Assistant."
|
|
date: 2017-06-18 12:00
|
|
sidebar: true
|
|
comments: false
|
|
sharing: true
|
|
footer: true
|
|
logo: knx.png
|
|
ha_category: Cover
|
|
ha_release: 0.48
|
|
ha_iot_class: "Local Polling"
|
|
---
|
|
|
|
|
|
The `knx` cover platform is used as in interface with KNX covers.
|
|
|
|
The `knx` component must be configured correctly, see [KNX Component](/components/knx).
|
|
|
|
To use your KNX covers in your installation, add the following to your `configuration.yaml` file:
|
|
|
|
```yaml
|
|
# Example configuration.yaml entry
|
|
cover:
|
|
- platform: knx
|
|
name: "Kitchen.Shutter"
|
|
move_long_address: '3/0/0'
|
|
move_short_address: '3/0/1'
|
|
position_address: '3/0/3'
|
|
position_state_address: '3/0/2'
|
|
travelling_time_down: 51
|
|
travelling_time_up: 61
|
|
```
|
|
|
|
Configuration variables:
|
|
|
|
- **name** (*Optional*): A name for this device used within Home Assistant.
|
|
- **move_long_address**: KNX group address for moving the cover full up or down.
|
|
- **move_short_address** (*Optional*): KNX group address for moving the cover short time up or down. If the KNX device has a stop group address you can use that here.
|
|
- **position_address** (*Optional*): KNX group address for moving the cover to the dedicated position.
|
|
- **position_state_address** (*Optional*): Separate KNX group address for requesting the current position of the cover.
|
|
- **angle_address** (*Optional*): KNX group address for moving the cover to the dedicated angle.
|
|
- **angle_state_address** (*Optional*): Separate KNX group address for requesting the current angle of cover.
|
|
- **travelling_time_down** (*Optional*): Time cover needs to travel down in seconds. Needed to calculate the intermediate positions of cover while traveling. Defaults to 25.
|
|
- **travelling_time_up** (*Optional*): Time cover needs to travel up in seconds. Needed to calculate the intermediate positions of cover while traveling. Defaults to 25.
|
|
- **invert_position** (*Optional*): Set this to true if your actuator report fully closed as 100%.
|
|
- **invert_angle** (*Optional*): Set this to true if your actuator reports tilt fully closed as 100%.
|
|
|