layout: page
|
|
title: "Modbus Switch"
|
|
description: "Instructions on how to integrate Modbus switches into Home Assistant."
|
|
date: 2015-08-30 23:38
|
|
sidebar: true
|
|
comments: false
|
|
sharing: true
|
|
footer: true
|
|
logo: modbus.png
|
|
ha_category: Switch
|
|
ha_release: pre 0.7
|
|
ha_iot_class: "Local Push"
|
|
---
|
|
|
|
|
|
The `modbus` switch platform allows you to control [Modbus](http://www.modbus.org/) coils or registers.
|
|
|
|
## {% linkable_title Configuration %}
|
|
|
|
To use your Modbus switches in your installation, add the following to your `configuration.yaml` file:
|
|
|
|
```yaml
|
|
# Example configuration.yaml entry
|
|
switch:
|
|
platform: modbus
|
|
slave: 1
|
|
coils:
|
|
- name: Switch1
|
|
slave: 1
|
|
coil: 13
|
|
- name: Switch2
|
|
slave: 2
|
|
coil: 14
|
|
registers:
|
|
- name: Register1
|
|
slave: 1
|
|
register: 11
|
|
command_on: 1
|
|
command_off: 0
|
|
```
|
|
|
|
Configuration variables:
|
|
|
|
- **coils** (*Optional*): A list of relevant coils to read from/write to.
|
|
- **slave** (*Required*): The number of the slave (can be omitted for tcp and udp Modbus).
|
|
- **name** (*Required*): Name of the switch.
|
|
- **coil** (*Required*): Coil number.
|
|
- **registers** (*Optional*): A list of relevant registers to read from/write to.
|
|
- **slave** (*Required*): The number of the slave (can be omitted for tcp and udp Modbus).
|
|
- **name** (*Required*): Name of the switch.
|
|
- **register** (*Required*): Register number.
|
|
- **command_on** (*Required*): Value to write to turn on the switch.
|
|
- **command_off** (*Required*): Value to write to turn off the switch.
|
|
- **verify_state** (*Optional*): Define if is possible to readback the status of the switch. (default: True)
|
|
- **verify_register** (*Optional*): Register to readback. (default: same as register)
|
|
- **register_type** (*Optional*): Modbus register type: holding or input. (default: holding)
|
|
- **state_on** (*Optional*): Register value when switch is on. (default: same as command_on)
|
|
- **state_off** (*Optional*): Register value when switch is off. (default: same as command_off)
|