3.8 KiB
title, description, logo, ha_category, ha_release, ha_iot_class
title | description | logo | ha_category | ha_release | ha_iot_class | |
---|---|---|---|---|---|---|
Modbus Sensor | Instructions on how to integrate Modbus sensors into Home Assistant. | modbus.png |
|
pre 0.7 | Local Push |
The modbus
sensor allows you to gather data from Modbus registers.
Configuration
To use your Modbus sensors in your installation, add the following to your configuration.yaml
file:
# Example configuration.yaml entry
sensor:
platform: modbus
registers:
- name: Sensor1
hub: hub1
unit_of_measurement: °C
slave: 1
register: 100
- name: Sensor2
hub: hub1
unit_of_measurement: mg
slave: 1
register: 110
count: 2
- name: Sensor3
hub: hub1
unit_of_measurement: °C
slave: 1
register: 120
register_type: input
data_type: float
scale: 0.01
offset: -273.16
precision: 2
{% configuration %} registers: description: The array contains a list of relevant registers to read from. required: true type: map keys: name: description: Name of the sensor. required: true type: string hub: description: The name of the hub. required: false default: default type: string slave: description: The number of the slave (Optional for tcp and upd Modbus). required: true type: integer register: description: Register number. required: true type: integer register_type: description: Modbus register type (holding, input), default holding. required: false type: string unit_of_measurement: description: Unit to attach to value. required: false type: integer device_class: description: The type/class of the sensor to set the icon in the frontend. required: false type: device_class default: None count: description: Number of registers to read. required: false type: integer default: 1 reverse_order: description: Reverse the order of registers when count >1. required: false default: false type: boolean scale: description: Scale factor (output = scale * value + offset). required: false default: 1 type: float offset: description: Final offset (output = scale * value + offset). required: false default: 0 type: float precision: description: Number of valid decimals. required: false default: 0 type: integer data_type: description: Response representation (int, uint, float, custom). If float selected, value will be converted to IEEE 754 floating point format. required: false default: int type: string structure: description: "If data_type is custom specify here a double quoted python struct format string to unpack the value. See python documentation for details. Ex: >i." required: false type: string {% endconfiguration %}
It's possible to change the default 30 seconds scan interval for the sensor updates as shown in the Platform options documentation.
If you specify scale or offset as floating point values, double precision floating point arithmetic will be used to calculate final value. This can cause loss of precision for values that are larger than 2^53.
Full example
Example a temperature sensor with a 10 seconds scan interval:
sensor:
- platform: modbus
scan_interval: 10
registers:
- name: Room_1
hub: hub1
slave: 10
register: 0
register_type: holding
unit_of_measurement: °C
count: 1
scale: 0.1
offset: 0
precision: 1
data_type: integer