home-assistant.io/source/_components/climate.honeywell.markdown
osirisinferi f4e530c099 Revert "MyTotalConnectComfort.com Compatibility (#5771)" (#7619)
The `honeywell.py` code uses either EvohomeClient *or* somecomfort
client code to connect to Honeywell, depending on the region (`eu`
or `us` respectively). The somecomfort client exclusively uses
mytotalconnectcomfort.com as API. Therefore, this warning seems a
little bit premature if you'd ask me.
2018-12-25 23:04:45 +01:00

67 lines
1.9 KiB
Markdown

---
layout: page
title: "Honeywell Thermostat"
description: "Instructions on how to integrate Honeywell thermostats within Home Assistant."
date: 2016-02-07 22:01
sidebar: true
comments: false
sharing: true
footer: true
logo: honeywell.png
ha_category: Climate
ha_release: pre 0.7
ha_iot_class: "Cloud Polling"
---
The `honeywell` climate platform let you control Honeywell Connected thermostats from Home Assistant.
To set it up, add the following information to your `configuration.yaml` file:
```yaml
climate:
- platform: honeywell
username: YOUR_USERNAME
password: YOUR_PASSWORD
scan_interval: 600
```
<p class='note'>
Scan interval is expressed in seconds. Omitting or mis-configuring `scan_interval` may result in too-frequent polling and cause you to be rate-limited by Honeywell.
</p>
{% configuration %}
username:
description: The username of an user with access.
required: true
type: string
password:
description: The password for your given admin account.
required: true
type: string
region:
description: Region identifier (either 'eu' or 'us'). Use the `somecomfort` client library for `us`, and evohome-client for `eu`.
required: false
default: eu
type: string
scan_interval:
description: Scan interval is expressed in seconds. Recommended value of 600 seconds. Omitting scan_interval may result in too-frequent polling and cause you to rate-limited by Honeywell.
required: false
default: 120
type: integer
away_temperature:
description: "(*only for eu region*) Heating setpoint when away mode is on, in deg C."
required: false
default: 16.0
type: float
away_cool_temperature:
description: "(*only for us region*) Cooling setpoint when away mode is on, in deg C."
required: false
default: 30.0
type: float
away_heat_temperature:
description: "(*only for us region*) Heating setpoint when away mode is on, in deg C."
required: false
default: 16.0
type: float
{% endconfiguration %}