* Sets front matter defaults * Removes default front matter from section templates/pages * Removes default front matter from addon pages * Removes default front matter from integration pages * Removes default front matter from posts * Removes default front matter from docs pages * Removes default front matter from other pages * Fixes blog category pages
2.8 KiB
2.8 KiB
title, description, logo, ha_category, ha_release, ha_iot_class
title | description | logo | ha_category | ha_release | ha_iot_class | |
---|---|---|---|---|---|---|
KNX Sensor | Instructions on how to use the KNX Sensor with Home Assistant. | knx.png |
|
0.29 | Local Push |
The knx
sensor platform allows you to monitor KNX sensors.
The knx
integration must be configured correctly, see KNX Component.
Configuration
To use your KNX sensor in your installation, add the following lines to your configuration.yaml
file:
# Example configuration.yaml entry
sensor:
- platform: knx
name: Heating.Valve1
address: '2/0/0'
{% configuration %} address: description: KNX group address of the sensor. required: true type: string name: description: A name for this device used within Home Assistant. required: false type: string type: description: A type from the following table can be defined. The DPT of the group address should match the expected KNX DPT to be parsed correctly. required: false type: string {% endconfiguration %}
type | unit | expected KNX DPT |
---|---|---|
percent | % | 5.001 |
pulse | 5.010 | |
temperature | °C | 9.001 |
humidity | % | 9.007 |
illuminance | lx | 9.004 |
brightness | lx | 7.013 |
speed_ms | m/s | 9.005 |
current | mA | 7.012 |
voltage | mV | 9.020 |
power | W | 14.056 |
electric_current | A | 14.019 |
electric_potential | V | 14.027 |
energy | J | 14.031 |
frequency | Hz | 14.033 |
heatflowrate | W | 14.036 |
phaseanglerad | rad | 14.054 |
phaseangledeg | ° | 14.055 |
powerfactor | 14.057 | |
speed | m/s | 14.065 |
enthalpy | H | 9.* |
ppm | ppm | 9.008 |
DPT-7 | 7.* | |
2byte_unsigned | 7.* | |
DPT-9 | 9.* | |
DPT-12 | 12.* | |
4byte_unsigned | 12.* | |
DPT-13 | 13.* | |
4byte_signed | 13.* | |
DPT-14 | 14.* | |
4byte_float | 14.* |
Full example
# Example configuration.yaml entry
sensor:
- platform: knx
name: Heating.Valve1
address: '2/0/0'
type: 'percent'
- platform: knx
name: Kitchen.Temperature
address: '6/2/1'
type: 'temperature'