ebusd |
The ebusd integration allows the integration between eBUS heating system and Home Assistant. |
|
Local Polling |
0.88 |
ebusd |
|
integration |
docs |
title |
/docs/configuration/ |
Configuration file |
|
|
legacy |
Integration between the ebusd daemon (used for communication with the eBUS heating systems), and Home Assistant. The ebusd integrations uses the sensor integration.
Configuration
Enable the sensor by adding the following to your {% term "configuration.yaml
" %} file.
{% include integrations/restart_ha_after_config_inclusion.md %}
# Example configuration.yaml entry
ebusd:
host: 127.0.0.1
circuit: "700"
{% configuration %}
host:
description: This is the IP address of your ebus daemon, e.g., 127.0.0.1
.
required: true
type: string
circuit:
description: The heating circuit name to monitor, e.g., '700', 'ehp' or 'bai'.
required: true
type: string
port:
description: The port your ebus daemon uses.
type: integer
required: false
default: 8888
name:
description: The name to use when displaying this ebusd instance.
type: string
required: false
default: ebusd
monitored_conditions:
description: List of conditions to monitor. Note that not all monitored_conditions listed here can be supported by your circuit. This integration maps limited set of keys to circuit specific ebusd values.
type: list
required: false
keys:
ActualFlowTemperatureDesired:
description: Heating circuit flow temperature desired.
MaxFlowTemperatureDesired:
description: Heating circuit maximum flow temperature.
MinFlowTemperatureDesired:
description: Heating circuit minimum flow temperature.
PumpStatus:
description: Heating circuit pump status.
HCSummerTemperatureLimit:
description: Heating circuit summer temperature limit.
HolidayTemperature:
description: Heating circuit holiday temperature.
HWTemperature:
description: Hot water circuit actual temperature.
HWTemperatureDesired:
description: Hot water circuit desired temperature.
HWTimerMonday:
description: Hot water circuit monday timer.
HWTimerTuesday:
description: Hot water circuit tuesday timer.
HWTimerWednesday:
description: Hot water circuit wednesday timer.
HWTimerThursday:
description: Hot water circuit thursday timer.
HWTimerFriday:
description: Hot water circuit friday timer.
HWTimerSaturday:
description: Hot water circuit saturday timer.
HWTimerSunday:
description: Hot water circuit sunday timer.
WaterPressure:
description: Water pressure (bar).
Zone1RoomZoneMapping:
description: Room controller assignment zone 1.
Zone1NightTemperature:
description: Heating circuit night temperature desired on zone 1.
Zone1DayTemperature:
description: Heating circuit day temperature desired on zone 1.
Zone1HolidayTemperature:
description: Heating circuit holiday temperature desired on zone 1.
Zone1RoomTemperature:
description: Actual room temperature on zone 1.
Zone1ActualRoomTemperatureDesired:
description: Actual room temperature desired on zone 1.
Zone1TimerMonday:
description: Heating circuit monday timer on zone 1.
Zone1TimerTuesday:
description: Heating circuit tuesday timer on zone 1.
Zone1TimerWednesday:
description: Heating circuit wednesday timer on zone 1.
Zone1TimerThursday:
description: Heating circuit thursday timer on zone 1.
Zone1TimerFriday:
description: Heating circuit friday timer on zone 1.
Zone1TimerSaturday:
description: Heating circuit saturday timer on zone 1.
Zone1TimerSunday:
description: Heating circuit sunday timer on zone 1.
Zone1OperativeMode:
description: Heating circuit operative mode (on/off/day/night).
ContinuosHeating:
description: Continuous heating.
PowerEnergyConsumptionLastMonth:
description: Power energy consumption from last month.
PowerEnergyConsumptionThisMonth:
description: Power energy consumption from the actual month.
HotWaterTemperature:
description: Hot water circuit temperature.
StorageTemperature:
description: Boiler temperature.
DesiredStorageTemperature:
description: Target boiler temperature.
OutdoorsTemperature:
description: Temperature used for weather dependent calculations.
AverageIgnitionTime:
description: Average flame ignition time (seconds).
MaximumIgnitionTime:
description: Maximum flame ignition time (seconds).
MinimumIgnitionTime:
description: Minimum flame ignition time (seconds).
ReturnTemperature:
description: Temperature returned into heater from water circuit.
DesiredFlowTemperature:
description: Target heat temperature.
FlowTemperature:
description: Out temperature.
{% endconfiguration %}