Franck Nijhof 4a9ea9c06a
Rename Services to Actions in integrations: R (#33826)
* Rename Services to Actions in integrations: R

* Update source/_integrations/rfxtrx.markdown

* Update source/_integrations/roku.markdown

* Update source/_integrations/roku.markdown

* Update source/_integrations/roku.markdown

* Update source/_integrations/rest_command.markdown

---------

Co-authored-by: c0ffeeca7 <38767475+c0ffeeca7@users.noreply.github.com>
2024-07-17 07:05:15 +02:00

2.3 KiB

title, description, ha_category, ha_release, ha_iot_class, ha_config_flow, ha_codeowners, ha_domain, ha_platforms, ha_integration_type
title description ha_category ha_release ha_iot_class ha_config_flow ha_codeowners ha_domain ha_platforms ha_integration_type
Renson Instructions on how to integrate Renson Endura Delta sensors into Home Assistant.
Binary sensor
Button
Fan
Number
Switch
Time
2023.7 Local Polling true
@jimmyd-be
renson
binary_sensor
button
fan
number
sensor
switch
time
integration

The Renson integration pulls in data from the Renson Endura delta device. Most of the sensors that can be monitored from inside the Android/iOS application can be monitored with this integration.

{% include integrations/config_flow.md %}

Actions

Action renson.set_timer_level

Set the ventilation timer.

Data attribute Required Description Example
timer_level yes Level setting
minutes yes Time of the timer (0 will disable the timer)

Action renson.set_breeze

Set the breeze function of the ventilation system.

Data attribute Required Description Example
breeze_level no Ventilation level when breeze function is activated
temperature no Temperature when the breeze function should be activated in °C
activate yes Activate or disable the breeze feature 2020-05-01T17:45:00

Action renson.set_pollution_settings

Set all the pollution settings of the ventilation system.

Data attribute Required Description Example
day_pollution_level no Ventilation level when pollution is detected in the day
night_pollution_level no Ventilation level when pollution is detected in the night
humidity_control no Activate or disable the humidity control
airquality_control no Activate or disable the air quality control
co2_control no Activate or disable the CO2 control 2020-05-01T17:45:00
co2_threshold no Sets the CO2 pollution threshold level in ppm 2020-05-01T17:45:00
co2_hysteresis no Sets the CO2 pollution threshold hysteresis level in ppm 2020-05-01T17:45:00