mirror of
https://github.com/home-assistant/home-assistant.io.git
synced 2025-05-06 11:08:59 +00:00

* Rename Services to Actions in integrations: R * Update source/_integrations/rfxtrx.markdown * Update source/_integrations/roku.markdown * Update source/_integrations/roku.markdown * Update source/_integrations/roku.markdown * Update source/_integrations/rest_command.markdown --------- Co-authored-by: c0ffeeca7 <38767475+c0ffeeca7@users.noreply.github.com>
2.3 KiB
2.3 KiB
title, description, ha_category, ha_release, ha_iot_class, ha_config_flow, ha_codeowners, ha_domain, ha_platforms, ha_integration_type
title | description | ha_category | ha_release | ha_iot_class | ha_config_flow | ha_codeowners | ha_domain | ha_platforms | ha_integration_type | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Renson | Instructions on how to integrate Renson Endura Delta sensors into Home Assistant. |
|
2023.7 | Local Polling | true |
|
renson |
|
integration |
The Renson integration pulls in data from the Renson Endura delta device. Most of the sensors that can be monitored from inside the Android/iOS application can be monitored with this integration.
{% include integrations/config_flow.md %}
Actions
Action renson.set_timer_level
Set the ventilation timer.
Data attribute | Required | Description | Example |
---|---|---|---|
timer_level |
yes | Level setting | |
minutes |
yes | Time of the timer (0 will disable the timer) |
Action renson.set_breeze
Set the breeze function of the ventilation system.
Data attribute | Required | Description | Example |
---|---|---|---|
breeze_level |
no | Ventilation level when breeze function is activated | |
temperature |
no | Temperature when the breeze function should be activated in °C | |
activate |
yes | Activate or disable the breeze feature | 2020-05-01T17:45:00 |
Action renson.set_pollution_settings
Set all the pollution settings of the ventilation system.
Data attribute | Required | Description | Example |
---|---|---|---|
day_pollution_level |
no | Ventilation level when pollution is detected in the day | |
night_pollution_level |
no | Ventilation level when pollution is detected in the night | |
humidity_control |
no | Activate or disable the humidity control | |
airquality_control |
no | Activate or disable the air quality control | |
co2_control |
no | Activate or disable the CO2 control | 2020-05-01T17:45:00 |
co2_threshold |
no | Sets the CO2 pollution threshold level in ppm | 2020-05-01T17:45:00 |
co2_hysteresis |
no | Sets the CO2 pollution threshold hysteresis level in ppm | 2020-05-01T17:45:00 |