Fronius Instructions on how to connect your Fronius SolarAPI devices to Home Assistant. 0.96
Energy
Sensor
@nielstron
@farmio
true fronius Local Polling
sensor
platinum true

The fronius integration polls a Fronius solar inverter or datalogger to allow you to get details from your Fronius SolarNet setup and integrate it in your Home Assistant installation.

Prerequisites

You will need to either set a static IP on the Fronius device or assign a static DHCP lease for it, or alternatively access it through the local DNS name if your network is properly configured for this. For Gen24 devices (delivered with Firmware >= 1.14.1) make sure to activate the "Solar API" in the inverters web interface.

{% include integrations/config_flow.md %}

Monitored data

Each device adds a set of sensors to Home Assistant.

  • SolarNet device

    • logger_info

      General information about the Fronius Datalogger. Not available on "Gen24" devices. Updated every hour.

      • The serial number and software and hardware platforms
      • The current price of energy consumed from the grid ("cash factor")
      • The current price of energy returned to the grid ("delivery factor")
    • power_flow

      Cumulative data such as the energy produced in the current day or year and overall produced energy. Updated every 10 seconds. Also, live values such as:

      • Power fed to the grid (if positive) or taken from the grid (if negative).
      • Power load as a generator (if positive) or consumer (if negative).
      • Battery charging power (if positive) or discharging power (if negative) and information about backup or standby mode.
      • Photovoltaic production.
      • Current relative self-consumption of produced energy.
      • Current relative autonomy.
  • inverter

    Cumulative data such as the energy produced in the current day or year and overall produced energy. Updated every minute. Also, live values about AC/DC power, current, voltage and frequency.

  • meter

    Detailed information about power, current and voltage, if supported split among the phases. Updated every minute.

  • ohmpilot

    Detailed information about energy, power, and temperature of your Ohmpilots. Updated every minute.

  • storage

    Detailed information about current, voltage, state, cycle count, capacity and more about installed batteries. Updated every minute.

Note that some data (like photovoltaic production) is only provided by the Fronius device when non-zero. The corresponding sensors are added to Home Assistant as entities as soon as they are available. This means for example that when Home Assistant is started at night, there might be no sensor providing photovoltaic related data. This does not need to be problematic as the values will be added on sunrise, when the Fronius devices begins providing the needed data. When a device is not responding correctly the update interval will increase to 10 minutes (3 minutes for power flow) until valid data is received again.

Energy dashboard

Recommended energy dashboard configuration for meter location in feed in path (Meter location: 0):

  • For Grid consumption use the meters Energy real consumed entity.
  • For Return to grid use the meters Energy real produced entity.
  • For Solar production:
    • If no battery is connected to an inverter: Add each inverters Energy total entity.
    • If a battery is connected to an inverter: Use Riemann sum over Power photovoltaics entity (from power_flow endpoint found in your SolarNet device)
  • Battery systems aren't supported directly. Use Template to split and invert negative values of Power battery entity (from power_flow) for charging power (W) and positive values for discharging power (W). Then use Riemann sum to integrate each into energy values (kWh).
  • For Devices use the Ohmpilots Energy consumed entity.

Note

Fronius often provides firmware updates for the datamanager interfaces and the devices in their system, it's recommended to check and apply them regularly. This integration relies on functionality present in rather recent firmware.