Patrick 1a84116b6a Updated to reflect the new API limits (#8124)
The free tier of OpenUV is now limited to 50, not 500.  All existing accounts will drop to that limit in February, but all new accounts have that limit.  The current scan_interval of 2/hr puts it at 48 calls/day (without any reboots triggering extras).  Should we adjust the default to be 1/hr or give documentation on how to not query it until the sun is above the horizon?
2019-01-14 22:55:58 +01:00

5.1 KiB

layout, title, description, date, sidebar, comments, sharing, footer, logo, ha_category, ha_release, ha_iot_class
layout title description date sidebar comments sharing footer logo ha_category ha_release ha_iot_class
page OpenUV Instructions on how to integrate OpenUV within Home Assistant. 2018-07-31 22:01 true false true true openuv.jpg Health 0.76 Cloud Polling

The openuv component displays UV and Ozone data from openuv.io.

{% linkable_title Generating an API Key %}

To generate an API key, simply log in to the OpenUV website.

Beginning February 1, 2019, the "Limited" plan (which is what new users are given by default) is limited to 50 API requests per day. Because different API plans and locations will have different requirements, the `openuv` component does not automatically query the API for new data after it initially loads. To request new data, the `update_data` service may be used.

{% linkable_title Configuration %}

To retrieve data from OpenUV, add the following to your configuration.yaml file:

openuv:
  api_key: YOUR_OPENUV_API_KEY

{% configuration %} api_key: description: The OpenUV API key. required: true type: string binary_sensors: description: The binary sensor-related configuration options. required: false type: map keys: monitored_conditions: description: The conditions to create sensors from. required: false type: list default: all keys: uv_protection_window: description: Displays if UV protection (sunscreen, etc.) is recommended at the current date and time. sensors: description: The sensor-related configuration options. required: false type: map keys: monitored_conditions: description: The conditions to create sensors from. required: false type: list default: all keys: current_ozone_level: description: The current ozone level in du (Dobson Units). current_uv_index: description: The current UV index. current_uv_level: description: "The level of current UV index, which is calculated based on UV Index Levels & Colors." max_uv_index: description: The maximum UV index that will be encountered that day (at solar noon). safe_exposure_time_type_1: description: The approximate exposure time for skin type I. safe_exposure_time_type_2: description: The approximate exposure time for skin type II. safe_exposure_time_type_3: description: The approximate exposure time for skin type III. safe_exposure_time_type_4: description: The approximate exposure time for skin type IV. safe_exposure_time_type_5: description: The approximate exposure time for skin type V. safe_exposure_time_type_6: description: The approximate exposure time for skin type VI. {% endconfiguration %}

The approximate number of minutes of a particular skin type can be exposed to the sun before burning/tanning starts is based on the Fitzpatrick scale.

{% linkable_title Full Configuration Example %}

To configure additional functionality, add configuration options beneath a binary_sensor and/or sensor key within the openuv section of the configuration.yaml file as below:

openuv:
  api_key: YOUR_OPENUV_API_KEY
  binary_sensors:
    monitored_conditions:
      - uv_protection_window
  sensors:
    monitored_conditions:
      - current_ozone_level
      - current_uv_index
      - current_uv_level
      - max_uv_index
      - safe_exposure_time_type_1
      - safe_exposure_time_type_2
      - safe_exposure_time_type_3
      - safe_exposure_time_type_4
      - safe_exposure_time_type_5
      - safe_exposure_time_type_6

The above guidelines constitute estimates and are intended to help informed decision making. They should not replace analysis, advice or diagnosis from a trained medical professional.

{% linkable_title Services %}

{% linkable_title openuv.update_data %}

Perform an on-demand update of OpenUV data.

{% linkable_title Examples of Updating Data %}

One method to retrieve data every 30 minutes and still leave plenty of API key usage is to only retrieve data during the daytime:

automation:
  - alias: Update OpenUV every 30 minutes during the daytime
    trigger:
      platform: time
      minutes: "/30"
      seconds: 00
    condition:
      condition: and
      conditions:
        - condition: sun
          after: sunrise
        - condition: sun
          before: sunset
    action:
      service: openuv.update_data

Another method (useful when monitoring locations other than the HASS latitude and longitude, in locations where there is a large amount of sunlight per day, etc.) might be to simply query the API less often:

automation:
  - alias: Update OpenUV every hour (24 of 50 calls per day)
    trigger:
      platform: time
      minutes: "/60"
      seconds: 00
    action: