layout: page
|
|
title: "One wire Sensor"
|
|
description: "Instructions on how to integrate One wire (1-wire) sensors into Home Assistant."
|
|
date: 2017-09-15 10:10
|
|
sidebar: true
|
|
comments: false
|
|
sharing: true
|
|
footer: true
|
|
logo: onewire.png
|
|
ha_category: DIY
|
|
ha_release: 0.12
|
|
ha_iot_class: "Local Polling"
|
|
---
|
|
|
|
The `onewire` platform supports sensors which are using the One wire (1-wire) bus for communication.
|
|
|
|
Supported devices:
|
|
|
|
- [DS18B20](https://datasheets.maximintegrated.com/en/ds/DS18B20.pdf)
|
|
- [DS18S20](https://www.maximintegrated.com/en/products/analog/sensors-and-sensor-interface/DS18S20.html)
|
|
- [DS1822](https://datasheets.maximintegrated.com/en/ds/DS1822.pdf)
|
|
- [DS1825](https://datasheets.maximintegrated.com/en/ds/DS1825.pdf)
|
|
- [DS28EA00](https://datasheets.maximintegrated.com/en/ds/DS28EA00.pdf) temperature sensors
|
|
- [DS2406/TAI-8570](https://datasheets.maximintegrated.com/en/ds/DS2406.pdf) Temperature and pressure sensor made by AAG
|
|
- [DS2438/B1-R1-A](https://datasheets.maximintegrated.com/en/ds/DS2438.pdf) Temperature, pressure and humidity sensor by AAG
|
|
|
|
The 1-Wire bus can be connected directly to the IO pins of Raspberry Pi or using dedicated interface adapter (e.g [DS9490R](https://datasheets.maximintegrated.com/en/ds/DS9490-DS9490R.pdf)).
|
|
|
|
#### Raspberry Pi setup
|
|
In order to setup 1-Wire support on Raspberry Pi, you'll need to edit `/boot/config.txt` following [this documentation](https://www.waveshare.com/wiki/Raspberry_Pi_Tutorial_Series:_1-Wire_DS18B20_Sensor#Enable_1-Wire). Don't use the `mount_dir` option.
|
|
|
|
#### Interface adapter setup
|
|
When an interface adapter is used, sensors can be accessed on Linux hosts via [owfs 1-Wire file system](http://owfs.org/). When using an interface adapter and the owfs, the `mount_dir` option must be configured to correspond a directory, where owfs device tree has been mounted.
|
|
|
|
<p class='note warning'>
|
|
This component has been modified to work with devices with multiple sensors which will cause a discontinuity in recorded values. Existing devices will receive a new ID and therefore show up as new devices.
|
|
If you wish to maintain continuity it can be resolved in the database by renaming the old devices to the new names.
|
|
|
|
Connect to your database using the instructions from [home-assistant.io/docs/backend/database/](https://home-assistant.io/docs/backend/database/). Check the names of sensors:
|
|
|
|
```sql
|
|
SELECT entity_id, COUNT(*) as count FROM states GROUP BY entity_id ORDER BY count DESC LIMIT 10;
|
|
```
|
|
Alter the names of sensors using the following examples:
|
|
|
|
```sql
|
|
UPDATE states SET entity_id='sensor.<sensor_name>_temperature' WHERE entity_id LIKE 'sensor.<sensor_name>%' AND attributes LIKE '%\u00b0C%';
|
|
UPDATE states SET entity_id='sensor.<sensor_name>_pressure' WHERE entity_id LIKE 'sensor.<sensor_name>%' AND attributes LIKE '%mb%';
|
|
UPDATE states SET entity_id='sensor.<sensor_name>_humidity' WHERE entity_id LIKE 'sensor.<sensor_name>%' AND attributes LIKE '%%%' ESCAPE '';
|
|
```
|
|
Remember to replace `<sensor_name>` with the actual name of the sensor as seen in the `SELECT` query.
|
|
</p>
|
|
|
|
#### Home Assistant setup
|
|
|
|
To enable One wire sensors in your installation, add the following to your `configuration.yaml` file:
|
|
|
|
```yaml
|
|
# Example configuration.yaml entry
|
|
sensor:
|
|
- platform: onewire
|
|
names:
|
|
some_id: your name
|
|
```
|
|
|
|
Configuration variables:
|
|
|
|
- **names** array (*Optional*): ID and friendly name of your sensors.
|
|
- **mount_dir** (*Optional*): Location of device tree if owfs driver used.
|
|
|