victorclaessen 057a20cde3
Add µs to duration device class for sensor and number components (#37922)
* Update number.markdown

add µs to duration

* Update sensor.markdown

add µs to duration
2025-03-11 21:48:44 +00:00

5.0 KiB

title description ha_category ha_release ha_quality_scale ha_domain ha_codeowners ha_integration_type related
Number Instructions on how to manage your Number entities with Home Assistant.
Number
2020.12 internal number
@home-assistant/core
@Shulyaka
entity
docs title
/docs/configuration/customizing-devices/ Customizing devices
docs title
/dashboards/ Dashboard

Keeps track on number entities in your environment, their state, and allows you to control them. This integration allows other integrations to get a value input from user within a range.

{% include integrations/building_block_integration.md %}

If you are looking for a way to create a number entity, please take a look at the Number helper.

The state of a number entity

The state of a number entity is a number.

In addition, the entity can have the following states:

  • Unavailable: The entity is currently unavailable.
  • Unknown: The state is not yet known.

Device class

{% include integrations/device_class_intro.md %}

The following device classes are supported for numbers:

  • None: Generic number. This is the default and doesn't need to be set.
  • apparent_power: Apparent power in VA.
  • aqi: Air Quality Index (unitless).
  • area: Area in m², cm², km², mm², in², ft², yd², mi², ac, ha
  • atmospheric_pressure: Atmospheric pressure in cbar, bar, hPa, mmHg, inHg, kPa, mbar, Pa or psi
  • battery: Percentage of battery that is left in %
  • blood_glucose_concentration: Blood glucose concentration in mg/dL, mmol/L
  • carbon_dioxide: Carbon Dioxide in CO2 (Smoke) in ppm
  • carbon_monoxide: Carbon Monoxide in CO (Gas CNG/LPG) in ppm
  • current: Current in A, mA
  • data_rate: Data rate in bit/s, kbit/s, Mbit/s, Gbit/s, B/s, kB/s, MB/s, GB/s, KiB/s, MiB/s or GiB/s
  • data_size: Data size in bit, kbit, Mbit, Gbit, B, kB, MB, GB, TB, PB, EB, ZB, YB, KiB, MiB, GiB, TiB, PiB, EiB, ZiB or YiB
  • distance: Generic distance in km, m, cm, mm, mi, nmi, yd, or in
  • duration: Duration in d, h, min, s, ms, or µs
  • energy: Energy in J, kJ, MJ, GJ, mWh, Wh, kWh, MWh, GWh, TWh, cal, kcal, Mcal, or Gcal
  • energy_distance: Energy per distance in kWh/100km, mi/kWh or km/kWh.
  • energy_storage: Stored energy in J, kJ, MJ, GJ, mWh, Wh, kWh, MWh, GWh, TWh, cal, kcal, Mcal, or Gcal
  • frequency: Frequency in Hz, kHz, MHz, or GHz
  • gas: Gasvolume in m³, ft³ or CCF
  • humidity: Percentage of humidity in the air in %
  • illuminance: The current light level in lx
  • irradiance: Irradiance in W/m² or BTU/(h⋅ft²)
  • moisture: Percentage of water in a substance in %
  • monetary: The monetary value (ISO 4217)
  • nitrogen_dioxide: Concentration of Nitrogen Dioxide in µg/m³
  • nitrogen_monoxide: Concentration of Nitrogen Monoxide in µg/m³
  • nitrous_oxide: Concentration of Nitrous Oxide in µg/m³
  • ozone: Concentration of Ozone in µg/m³
  • ph: Potential hydrogen (pH) value of a water solution
  • pm1: Concentration of particulate matter less than 1 micrometer in µg/m³
  • pm25: Concentration of particulate matter less than 2.5 micrometers in µg/m³
  • pm10: Concentration of particulate matter less than 10 micrometers in µg/m³
  • power_factor: Power factor (unitless), unit may be None or %
  • power: Power in mW, W, kW, MW, GW or TW
  • precipitation: Accumulated precipitation in cm, in or mm
  • precipitation_intensity: Precipitation intensity in in/d, in/h, mm/d or mm/h
  • pressure: Pressure in Pa, kPa, hPa, bar, cbar, mbar, mmHg, inHg or psi
  • reactive_power: Reactive power in var
  • signal_strength: Signal strength in dB or dBm
  • sound_pressure: Sound pressure in dB or dBA
  • speed: Generic speed in ft/s, in/d, in/h, in/s, km/h, kn, m/s, mph, mm/d, or mm/s
  • sulphur_dioxide: Concentration of sulphur dioxide in µg/m³
  • temperature: Temperature in °C, °F or K
  • volatile_organic_compounds: Concentration of volatile organic compounds in µg/m³
  • volatile_organic_compounds_parts: Ratio of volatile organic compounds in ppm or ppb
  • voltage: Voltage in V, mV, µV, kV, MV
  • volume: Generic volume in L, mL, gal, fl. oz., m³, ft³, or CCF
  • volume_flow_rate: Volume flow rate in m³/h, ft³/min, L/min, gal/min, or mL/s
  • volume_storage: Generic stored volume in L, mL, gal, fl. oz., m³, ft³, or CCF
  • water: Water consumption in L, gal, m³, ft³, or CCF
  • weight: Generic mass in kg, g, mg, µg, oz, lb, or st
  • wind_direction: Wind direction in °
  • wind_speed: Wind speed in Beaufort, ft/s, km/h, kn, m/s, or mph

Actions

The Number entities registers the following actions:

Action Data Description
set_value value
entity_id(s)
area_id(s)
Set the value of specific number entities