The `honeywell` climate platform let you control [Honeywell Connected](http://getconnected.honeywell.com/en/) thermostats from Home Assistant.
|
|
|
|
To set it up, add the following information to your `configuration.yaml` file:
|
|
|
|
```yaml
|
|
climate:
|
|
- platform: honeywell
|
|
username: YOUR_USERNAME
|
|
password: YOUR_PASSWORD
|
|
scan_interval: 600
|
|
```
|
|
<p class='note'>
|
|
Scan interval is expressed in seconds. Omitting scan_interval may result in too-frequent polling and cause you to rate-limited by Honeywell.
|
|
</p>
|
|
|
|
Configuration variables:
|
|
|
|
- **username** (*Required*): The username of an user with access.
|
|
- **password** (*Required*): The password for your given admin account.
|
|
- **region** (*Optional*): Region identifier (either 'eu' or 'us'). Defaults to 'eu' if not provided.
|
|
- **scan_interval**(*Optional*): Scan interval is expressed in seconds. Recommended value of 600 seconds. Default value is 120 seconds. Omitting scan_interval may result in too-frequent polling and cause you to rate-limited by Honeywell.
|
|
- **away_temperature** (*Optional*) (*only for eu region*): Heating setpoint when away mode is on. If omitted it defaults to 16.0 deg C.
|
|
- **away_cool_temperature** (*Optional*) (*only for us region*): Cooling setpoint when away mode is on. If omitted it defaults to 30.0 deg C.
|
|
- **away_heat_temperature** (*Optional*) (*only for us region*): Heating setpoint when away mode is on. If omitted it defaults to 16.0 deg C.
|