home-assistant.io/source/_components/climate.modbus.markdown
2018-05-08 09:34:28 +02:00

72 lines
1.8 KiB
Markdown

---
layout: page
title: "Modbus"
description: "Instructions how to integrate a Modbus thermostat within Home Assistant."
date: 2018-01-29 9:35
sidebar: true
comments: false
sharing: true
footer: true
logo: modbus.png
ha_category: Thermostat
ha_release: 0.68
ha_iot_class: "Local Polling"
---
The `modbus` thermostat allows you to use a sensor value (current temperature) and target value (target temperature) from [Modbus](http://www.modbus.org/) registers.
## {% linkable_title Configuration %}
To use your Modbus thermostat in your installation, add the following to your `configuration.yaml` file:
```yaml
# Example configuration.yaml entry
climate:
- platform: modbus
name: Watlow F4T
slave: 1
target_temp_register: 2782
current_temp_register: 27586
```
{% configuration %}
name:
description: Name of the device
required: true
type: string
slave:
description: The number of the slave (Optional for tcp and upd Modbus, use 1).
required: true
type: int
target_temp_register:
description: Register number for target temperature (Setpoint).
required: true
type: int
current_temp_register:
description: Register number for current temperature (Process value).
required: true
type: int
data_type:
description: Response representation (int, uint, float, custom). If float selected, value will converted to IEEE 754 floating point format.
required: false
type: string
default: float
count:
description: Number of registers to read.
required: false
type: int
precision:
description: Number of valid decimals.
required: false
type: int
default: 0
{% endconfiguration %}
### {% linkable_title Services %}
| Service | Description |
| ------- | ----------- |
| set_temperature | Set Temperature. Requires `value` to be passed in, which is the desired target temperature. `value` should be in the same type as `data_type` |