home-assistant.io/source/_components/konnected.markdown
2018-05-15 23:22:15 +02:00

6.1 KiB

layout, title, description, date, sidebar, comments, sharing, footer, logo, ha_category, ha_release
layout title description date sidebar comments sharing footer logo ha_category ha_release
page Konnected Connect wired alarm sensors and siren using the NodeMCU based Konnected Alarm Panel 2018-04-03 12:30 true false true true konnected.png Alarm 0.70

The konnected component lets you connect wired sensors and switches to a NodeMCU ESP8226 based device running the open source Konnected software. Reuse the wired sensors and siren from an old or pre-wired alarm system installation and integrate them directly into Home Assistant.

Visit the Konnected.io website for more information about the Konnected Alarm Panel board and compatible hardware.

The component currently supports the following device types in Home Assistant:

  • Binary Sensor: Wired door and window sensors, motion detectors, glass-break detectors, leak sensors, smoke & CO detectors or any open/close switch.
  • Switch: Actuate a siren, strobe, buzzer or relay module.

This component requires the discovery component to be enabled.

{% linkable_title Configuration %}

A konnected section must be present in the configuration.yml file that specifies the Konnected devices on the network and the sensors or actuators attached to them:

# Example configuration.yaml entry
konnected:
  access_token: REPLACE_ME_WITH_A_RANDOM_STRING
  devices:
    - id: 8bcd53
      binary_sensors:
        - zone: 1
          type: door
      switches:
        - zone: out
    - id: 438a38
      binary_sensors:
        - pin: 2
          type: door
      switches:
        - pin: 5

{% configuration %} access_token: description: Any random string. This is used to ensure that only those devices which you have configured can authenticate to Home Assistant to change a device state. required: true type: string devices: description: A list of Konnected devices that you have on your network. required: true type: list keys: id: description: The MAC address of the WiFi module with colons/punctuation removed. You can either use the full 12-character MAC address or only the last 6 characters. This is visible in the device's WiFi SSID and hostname. required: true type: string binary_sensors: description: A list of binary sensors connected to the device. See Konnected Binary Sensor for configuration variables. required: false type: list keys: pin: description: The number corresponding to the IO index of the labeled pin on the NodeMCU dev board. See the NodeMCU GPIO documentation for more details. Valid values are 1, 2, 5, 6, 7 and 9. required: exclusive zone: description: The number corresponding to the labeled zone on the Konnected Alarm Panel board. Valid values are 1, 2, 3, 4, 5 and 6. required: exclusive type: description: Any binary sensor class, typically door, window, motion or smoke. required: true name: description: The name of the device used in the front end. required: false default: automatically generated switches: description: A list of actuators (on/off switches) connected to the device. See Konnected Switch for configuration variables. required: false type: list keys: pin: description: The number corresponding to the IO index of the labeled pin on the NodeMCU dev board. See the NodeMCU GPIO documentation for more details. Valid values are 1, 2, 5, 6, 7 and 8. required: exclusive zone: description: The number corresponding to the labeled zone on the Konnected Alarm Panel board or the word out to specify the dedicated ALARM/OUT terminal on the Konnected board. Valid values are 1, 2, 3, 4, 5 and out. required: exclusive name: description: The name of the device used in the front end. required: false default: automatically generated activation: description: Either "low" or "high" to specify the state when the switch is turned on. default: high required: false {% endconfiguration%}

Configuration Notes

  • Either pin or zone is required for each actuator or sensor. Do not use both in the same definition.
  • Pin D8 or the out zone will only work when activation is set to high (the default).

{% linkable_title Full configuration %}

# Example configuration.yaml entry
konnected:
  access_token: REPLACE_ME_WITH_A_RANDOM_STRING
  devices:
    - id: 8bcd53
      binary_sensors:
        - zone: 1
          type: door
          name: 'Front Door'
        - zone: 3
          type: motion
          name: 'Test Motion'
      switches:
        - zone: out
          name: siren
    - id: 438a38
      binary_sensors:
        - pin: 1
          type: motion
          name: 'Office Motion'
        - pin: 2
          type: door
          name: 'Office Door'
      switches:
        - pin: 5
          name: 'Garage Door'
          activation: low

{% linkable_title Pin Mapping %}

Konnected runs on an ESP8266 board with the NodeMCU firmware. It is commonly used with the NodeMCU dev kit WiFi module and optionally Konnected's Alarm Panel hardware. The following table shows the pin mapping between the Konnected hardware labeled zones, the NodeMCU labeled pins and the ESP8266 GPIO pins.

Konnected Alarm Panel Zone NodeMCU pin IO Index ESP8266 GPIO
1 D1 1 GPIO5
2 D2 2 GPIO4
3 D5 5 GPIO14
4 D6 6 GPIO12
5 D7 7 GPIO13
6 RX 9 GPIO3
ALARM or OUT D8 8 GPIO15