Fixes typo in the first sentence of "Ping (ICMP) Binary sensor" docs: https://www.home-assistant.io/components/binary_sensor.ping/
2.0 KiB
layout | title | description | date | sidebar | comments | sharing | footer | logo | ha_category | ha_release | ha_qa_scale |
---|---|---|---|---|---|---|---|---|---|---|---|
page | Ping (ICMP) Binary sensor | Instructions on how to integrate Ping (ICMP)-based binary sensors into Home Assistant. | 2017-04-11 08:00 | true | false | true | true | home-assistant.png | Network | 0.43 | internal |
The ping
binary sensor platform allows you to use ping
to send ICMP echo requests. This way you can check if a given host is online and determine the round trip times from your Home Assistant instance to that system.
{% linkable_title Configuration %}
To use this sensor in your installation, add the following to your configuration.yaml
file:
# Example configuration.yaml entry
binary_sensor:
- platform: ping
host: 192.168.0.1
{% configuration %} host: description: The IP address or hostname of the system you want to track. required: true type: string count: description: Number of packets to send. required: false type: integer default: 5 name: description: Let you overwrite the name of the device. required: false type: string default: Ping Binary sensor {% endconfiguration %}
The sensor exposes the different round trip times values measured by ping
as attributes:
round trip time mdev
round trip time avg
round trip time min
round trip time max
The default polling interval is 5 minutes. As many components based on the entity class, it is possible to overwrite this scan interval by specifying a scan_interval
configuration key (value in seconds). In the example below we setup the ping
binary sensor to poll the devices every 30 seconds.
# Example configuration.yaml entry to ping host 192.168.0.1 with 2 packets every 30 seconds.
binary_sensor:
- platform: ping
host: 192.168.0.1
count: 2
scan_interval: 30
When run on Windows systems, the round trip time attributes are rounded to the nearest millisecond and the mdev value is unavailable.