title: Switcher
|
|
description: Controlling your Switcher V2 Water Heater.
|
|
ha_category:
|
|
- Switch
|
|
ha_release: 0.93
|
|
ha_iot_class: Local Push
|
|
ha_codeowners:
|
|
- '@tomerfi'
|
|
ha_domain: switcher_kis
|
|
---
|
|
|
|
This `Switcher` integration allows you to control the [Switcher V2 Water Heater](https://www.switcher.co.il/).
|
|
|
|
To enable it, add an entry to your `configuration.yaml` according to the following configuration instructions.
|
|
|
|
To retrieve your device's details, please follow the instructions [here](https://github.com/NightRang3r/Switcher-V2-Python).
|
|
|
|
<div class='note warning'>
|
|
Please note, the Switcher-V2-Python script is written in python 2.7 syntax, it won't run with python 3.x.
|
|
</div>
|
|
|
|
<div class='note warning'>
|
|
Please note, for the Switcher-V2-Python script to run successfully, you need to configure your device to work locally.
|
|
</div>
|
|
|
|
```yaml
|
|
switcher_kis:
|
|
phone_id: 'REPLACE_WITH_PHONE_ID'
|
|
device_id: 'REPLACE_WITH_DEVICE_ID'
|
|
device_password: 'REPLACE_WITH_DEVICE_PASSWORD'
|
|
```
|
|
|
|
{% configuration %}
|
|
phone_id:
|
|
description: The device's phone id.
|
|
required: true
|
|
type: string
|
|
device_id:
|
|
description: The device's id.
|
|
required: true
|
|
type: string
|
|
device_password:
|
|
description: The device's password.
|
|
required: true
|
|
type: string
|
|
{% endconfiguration %}
|
|
|
|
## Switch State Attributes
|
|
|
|
| Attribute | Type | Description | Example |
|
|
| ------------------ | ------- | ------------------------------------------------------ | ----------------- |
|
|
| `friendly_name` | string | Defaults to the device's configured name. | "Switcher Boiler" |
|
|
| `auto_off_set` | string | The auto shutdown time limit configured on the device. | "01:30:00" |
|
|
| `remaining_time` | string | Time remaining to shutdown (auto or timer). | "01:29:41" |
|
|
| `electric_current` | float | The electric current in amps. | 12.5 |
|
|
| `current_power_w` | integer | The current power used in watts. | 2756 |
|
|
|
|
<div class='note warning'>
|
|
|
|
Please note, the following attributes are not eligible when the device is off and therefore will not appear as state attributes: `remaining_time`, `electric_current`, `current_power_w`.
|
|
|
|
</div>
|
|
|
|
## Services
|
|
|
|
### Service: `switcher_kis.set_auto_off`
|
|
|
|
You can use the `switcher_kis.set_auto_off` service to set the auto-off configuration setting for the device.
|
|
|
|
Meaning the device will turn itself off when reaching the auto-off configuration limit.
|
|
|
|
| Service Field | Mandatory | Description | Example |
|
|
| ------------- | --------- | -------------------------------------------------------------------------------------- | -------------------------- |
|
|
| `entity_id` | Yes | Name of the entity id associated with the integration, used for permission validation. | switch.switcher_kis_boiler |
|
|
| `auto_off` | Yes | Time period string containing hours and minutes. | "02:30" |
|