3.4 KiB
layout, title, description, date, sidebar, comments, sharing, footer, logo, ha_category, ha_release, ha_iot_class
layout | title | description | date | sidebar | comments | sharing | footer | logo | ha_category | ha_release | ha_iot_class |
---|---|---|---|---|---|---|---|---|---|---|---|
page | Modbus | Instructions on how to integrate Modbus within Home Assistant. | 2015-04-25 9:16 | true | false | true | true | modbus.png | Hub | pre 0.7 | Local Push |
Modbus is a serial communication protocol to control PLCs (Programmable logic controller). It currently supports sensors and switches which can be controlled over serial, TCP, and UDP connections.
{% linkable_title Configuration %}
The configuration for adding modbus to your installation depends on the connection type, either a network or serial connection.
{% linkable_title Network connection %}
For a network connection, add the following to your configuration.yaml
file:
# Example configuration.yaml entry for a TCP connection
modbus:
type: tcp
host: IP_ADDRESS
port: 2020
{% configuration %}
type:
description: Type of the connection to Modbus. Possible values are tcp
(Modbus TCP protocol according to "MODBUS Messaging Implementation Guide version 1.0b" provided by Schneider Automation.), udp
(Modbus TCP form, but using UDP for transport. It removes the overheads required for TCP.) and rtuovertcp
(Modbus RTU message transmitted with a TCP/IP wrapper and sent over a network instead of serial lines.).
required: true
type: string
host:
description: The IP address of your Modbus device, e.g., 192.168.1.1.
required: true
type: string
port:
description: The network port for the communication.
required: true
type: integer
timeout:
description: Timeout for slave response in seconds.
required: false
default: 3
type: integer
{% endconfiguration %}
{% linkable_title Serial connection %}
For a serial connection, add the following to your configuration.yaml
file:
# Example configuration.yaml entry for a serial connection
modbus:
type: serial
method: rtu
port: /dev/ttyUSB0
baudrate: 9600
stopbits: 1
bytesize: 8
parity: N
{% configuration %}
type:
description: "Type of the connection to Modbus, needs to be serial
for this setup."
required: true
type: string
method:
description: "Method of the connection to Modbus, either rtu
or ascii
."
required: true
type: string
port:
description: The port where your Modbus device is connected to your Home Assistant host.
required: true
type: string
baudrate:
description: The speed for the serial connection.
required: true
type: integer
stopbits:
description: "The stopbits for the serial connection, either 1
or 2
."
required: true
type: integer
bytesize:
description: "The bytesize for the serial connection; can be 5
, 6
, 7
or 8
."
required: true
type: integer
parity:
description: "The parity for the serial connection; can be E
, O
or N
."
required: true
type: string
timeout:
description: Timeout for slave response in seconds.
required: false
default: 3
type: integer
{% endconfiguration %}
{% linkable_title Services %}
Service | Description |
---|---|
write_register | Write register. Requires unit , address and value fields. value can be either single value or an array |