home-assistant.io/source/_integrations/switcher_kis.markdown

3.9 KiB

title description ha_category ha_release ha_iot_class ha_codeowners ha_domain
Switcher Controlling your Switcher V2 Water Heater.
Switch
0.93 Local Push
@tomerfi
switcher_kis

This Switcher integration allows you to control the Switcher V2 Water Heater.

To enable it, add an entry to your configuration.yaml according to the following configuration instructions.

To retrieve your device's details, please follow the instructions here.

Please note, the Switcher-V2-Python script is written in python 2.7 syntax, it won't run with python 3.x.
Please note, for the Switcher-V2-Python script to run successfully, you need to configure your device to work locally.
switcher_kis:
  phone_id: 'REPLACE_WITH_PHONE_ID'
  device_id: 'REPLACE_WITH_DEVICE_ID'
  device_password: 'REPLACE_WITH_DEVICE_PASSWORD'

{% configuration %} phone_id: description: The device's phone id. required: true type: string device_id: description: The device's id. required: true type: string device_password: description: The device's password. required: true type: string {% endconfiguration %}

Switch State Attributes

Attribute Type Description Example
friendly_name string Defaults to the device's configured name. "Switcher Boiler"
auto_off_set string The auto shutdown time limit configured on the device. "01:30:00"
remaining_time string Time remaining to shutdown (auto or timer). "01:29:41"
electric_current float The electric current in amps. 12.5
current_power_w integer The current power used in watts. 2756

Please note, the following attributes are not eligible when the device is off and therefore will not appear as state attributes: remaining_time, electric_current, current_power_w.

Services

Service: switcher_kis.set_auto_off

You can use the switcher_kis.set_auto_off service to set the auto-off configuration setting for the device.

Meaning the device will turn itself off when reaching the auto-off configuration limit.

Service Field Mandatory Description Example
entity_id Yes Name of the entity id associated with the integration, used for permission validation. switch.switcher_kis_boiler
auto_off Yes Time period string containing hours and minutes. "02:30"

Service: switcher_kis.turn_on_with_timer

You can use the switcher_kis.turn_on_with_timer service to turn on the switcher device with timer.

Meaning the device will turn itself off when timer ends. Note: This does not affect the auto off timer.

Service Field Mandatory Description Example
entity_id Yes Name of the entity id associated with the integration, used for permission validation. switch.switcher_kis_boiler
timer_minutes Yes Integer containing timer minutes (valid range 1 to 90) 90