* m-o integrations: apply sentence-style caps to categories * Apply suggestions from code review Co-authored-by: Joakim Sørensen <joasoe@gmail.com> * Apply suggestions from code review Co-authored-by: Joakim Sørensen <joasoe@gmail.com> * Apply suggestions from code review Co-authored-by: Joost Lekkerkerker <joostlek@outlook.com> --------- Co-authored-by: Joakim Sørensen <joasoe@gmail.com> Co-authored-by: Joost Lekkerkerker <joostlek@outlook.com>
105 lines
2.8 KiB
Markdown
105 lines
2.8 KiB
Markdown
---
|
|
title: Nexia/American Standard/Trane
|
|
description: Instructions on how to integrate Trane and American Standard thermostats into Home Assistant.
|
|
ha_category:
|
|
- Binary sensor
|
|
- Climate
|
|
- Scene
|
|
- Sensor
|
|
- Switch
|
|
ha_release: 0.108
|
|
ha_iot_class: Cloud Polling
|
|
ha_config_flow: true
|
|
ha_codeowners:
|
|
- '@bdraco'
|
|
ha_domain: nexia
|
|
ha_dhcp: true
|
|
ha_platforms:
|
|
- binary_sensor
|
|
- climate
|
|
- diagnostics
|
|
- number
|
|
- scene
|
|
- sensor
|
|
- switch
|
|
ha_integration_type: integration
|
|
---
|
|
|
|
The `nexia` integration allows you to integrate your [Nexia](https://mynexia.com/) (Trane) thermostats or [American Standard](https://asairhome.com/) thermostats into Home Assistant.
|
|
|
|
There is currently support for the following device types within Home Assistant:
|
|
|
|
- [Binary sensor](#binary-sensor)
|
|
- [Climate](#climate)
|
|
- [Sensor](#sensor)
|
|
- [Scene](#scene)
|
|
- [Switch](#switch)
|
|
|
|
{% include integrations/config_flow.md %}
|
|
|
|
### Binary sensor
|
|
|
|
The following binary sensors are added for each thermostat:
|
|
|
|
- Blower Active
|
|
|
|
### Sensor
|
|
|
|
The following sensors are added for each thermostat:
|
|
|
|
- Air Cleaner Mode
|
|
- Current Compressor Speed
|
|
- Requested Compressor Speed
|
|
- Outdoor Temperature
|
|
- Relative Humidity
|
|
- System Status
|
|
|
|
The following sensors are added for each thermostat zone:
|
|
|
|
- Zone Temperature
|
|
- Zone Setpoint Status
|
|
- Zone Status
|
|
|
|
### Climate
|
|
|
|
The climate platform lets you control a thermostat.
|
|
|
|
The following Trane thermostats are supported: `XL1050`, `XL850`, `XL824`
|
|
|
|
The following American Standard thermostats have been reported to work: `AZONE1050`, `AZONE850`, `ACONT824`
|
|
|
|
The following thermostats are not supported: `XL624`, `XL950`, `AZONE950`, `AZEMT500`, `AZEMT400B`
|
|
|
|
Other thermostats may work, but they have not been tested.
|
|
|
|
### Number
|
|
|
|
The number platform lets you adjust the fan speed on systems with variable-speed fan support.
|
|
|
|
### Scene
|
|
|
|
The scene platform lets you activate a nexia automation.
|
|
|
|
### Switch
|
|
|
|
The switch platform lets you enable or disable hold mode for each thermostat.
|
|
|
|
### Service `nexia.set_aircleaner_mode`
|
|
|
|
Sets the air cleaner mode. Options include 'auto', 'quick', and
|
|
'allergy'. This setting will affect all zones on the same thermostat.
|
|
|
|
| Service data attribute | Optional | Description |
|
|
| ---------------------- | -------- | ----------- |
|
|
| `entity_id` | no | String or list of strings that point at `entity_id`'s of climate devices to control.
|
|
| `aircleaner_mode` | no | 'auto', 'quick', or 'allergy'
|
|
|
|
### Service `nexia.set_humidify_setpoint`
|
|
|
|
Sets the humidify setpoint. This setting will affect all zones on the same thermostat.
|
|
|
|
| Service data attribute | Optional | Description |
|
|
| ---------------------- | -------- | ----------- |
|
|
| `entity_id` | no | String or list of strings that point at `entity_id`'s of climate devices to control.
|
|
| `humidity` | no | Humidify setpoint level, from 35 to 65.
|