The Renson integration pulls in data from the Renson Endura delta device. Most of the sensors that can be monitored from inside the Android/iOS application can be monitored with this integration.
|
|
|
|
{% include integrations/config_flow.md %}
|
|
|
|
## Services
|
|
|
|
### Service `renson.set_timer_level`
|
|
|
|
Set the ventilation timer.
|
|
|
|
| Service data attribute | Required | Description | Example |
|
|
| ---------------------- | -------- | ----------- | ------- |
|
|
| `timer_level`| yes | Level setting | |
|
|
| `minutes` | yes | Time of the timer (0 will disable the timer) | |
|
|
|
|
### Service `renson.set_breeze`
|
|
|
|
Set the breeze function of the ventilation system.
|
|
|
|
| Service data attribute | Required | Description | Example |
|
|
| ---------------------- | -------- | ----------- | ------- |
|
|
| `breeze_level`| no | Ventilation level when breeze function is activated | |
|
|
| `temperature` | no | Temperature when the breeze function should be activated in °C | |
|
|
| `activate` | yes | Activate or disable the breeze feature | `2020-05-01T17:45:00` |
|
|
|
|
### Service `renson.set_pollution_settings`
|
|
|
|
Set all the pollution settings of the ventilation system.
|
|
|
|
| Service data attribute | Required | Description | Example |
|
|
| ---------------------- | -------- | ----------- | ------- |
|
|
| `day_pollution_level`| no | Ventilation level when pollution is detected in the day | |
|
|
| `night_pollution_level` | no | Ventilation level when pollution is detected in the night | |
|
|
| `humidity_control` | no | Activate or disable the humidity control | |
|
|
| `airquality_control` | no | Activate or disable the air quality control | |
|
|
| `co2_control` | no | Activate or disable the CO2 control | `2020-05-01T17:45:00` |
|
|
| `co2_threshold` | no | Sets the CO2 pollution threshold level in ppm | `2020-05-01T17:45:00` |
|
|
| `co2_hysteresis` | no | Sets the CO2 pollution threshold hysteresis level in ppm | `2020-05-01T17:45:00` |
|