title: The Energy Detective TED5000
description: How to add a TED5000 to Home Assistant.
ha_category:
- Energy
ha_release: '0.30'
ha_iot_class: Local Polling
ha_domain: ted5000
ha_platforms:
- sensor
ha_integration_type: integration
---
The `ted 5000` monitors electricity consumption/production by connecting to the [TED](https://www.theenergydetective.com/) gateway, itself connected to one or several Measuring Transmitting Units (MTU). The platform creates up to two sensors per MTU, one for Wattage the other for Voltage.
If you want to enable the ted5000 sensor, add the following lines to your `configuration.yaml`:
```yaml
# Example configuration.yaml entry
sensor:
- platform: ted5000
host: 192.168.1.100
```
{% configuration %}
host:
description: The IP address of your ted gateway.
required: true
type: string
port:
description: The port of your ted gateway.
required: false
type: integer
default: 80
name:
description: Name of the ted gateway.
required: false
type: string
default: ted
{% endconfiguration %}
For each plugged MTU, using an index starting at 1, the platform creates 2 sensors:
```yaml
sensor.<name>_mtu<MTU id>_power
sensor.<name>_mtu<MTU id>_voltage
```