title | description | ha_category | ha_release | ha_iot_class | ha_codeowners | ha_domain | ha_platforms | ha_config_flow | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Switcher | Integrate Switcher devices. |
|
0.93 | Local Push |
|
switcher_kis |
|
true |
This Switcher
integration allows you to control your Switcher Devices.
Supported devices:
- Switcher Power Plug
- Switcher Touch (from firmware 1.51)
- Switcher V2 (Espressif chipset - from firmware 3.21)
- Switcher V2 (Qualcomm chipset - from firmware 72.32)
- Switcher V4
If you completed the integration setup but are still unable to control the device, please make sure your device's firmware is up-to-date.
{% include integrations/config_flow.md %}
Sensors
Sensor Name | Description | Example |
---|---|---|
Auto Shutdown |
The auto shutdown time limit configured on the device | 01:30:00 |
Remaining Time |
Time remaining to shutdown (auto or timer) | 01:29:41 |
Electric Current |
The electric current in amps | 12.5 A |
Power Consumption |
The power consumption in watts | 2756 W |
Services
Service: switcher_kis.set_auto_off
You can use the switcher_kis.set_auto_off
service to set the auto-off configuration setting for the device.
Meaning the device will turn itself off when reaching the auto-off configuration limit.
Service Field | Mandatory | Description | Example |
---|---|---|---|
entity_id |
Yes | Name of the entity id associated with the integration, used for permission validation | switch.switcher_kis_boiler |
auto_off |
Yes | Time period string containing hours and minutes | "02:30" |
Service: switcher_kis.turn_on_with_timer
You can use the switcher_kis.turn_on_with_timer
service to turn on the switcher device with timer.
Meaning the device will turn itself off when timer ends. Note: This does not affect the auto off timer.
Service Field | Mandatory | Description | Example |
---|---|---|---|
entity_id |
Yes | Name of the entity id associated with the integration, used for permission validation | switch.switcher_kis_boiler |
timer_minutes |
Yes | Integer containing timer minutes (valid range 1 to 150) | 90 |