page KNX Climate Instructions on how to integrate KNX thermostats with Home Assistant. 2016-06-24 12:00 true false true true knx.png Climate 0.25 Local Polling

The knx climate platform is used as in interface with KNX thermostats.

The knx component must be configured correctly, see KNX Component.

To use your KNX thermostats in your installation, add the following lines to your configuration.yaml file:

# Example configuration.yaml entry
climate:
   - platform: knx
     name: HASS-Kitchen.Temperature
     temperature_address: '5/1/1'
     setpoint_shift_address: '5/1/2'
     setpoint_shift_state_address: '5/1/3'
     target_temperature_address: '5/1/4'
     operation_mode_address: '5/1/5'

Alternatively, if your device has dedicated binary group addresses for frost/night/comfort mode:

# Example configuration.yaml entry
climate:
  - platform: knx
    name: HASS-Kitchen.Temperature
    temperature_address: '5/1/1'
    setpoint_shift_address: '5/1/2'
    setpoint_shift_state_address: '5/1/3'
    target_temperature_address: '5/1/4'
    operation_mode_frost_protection_address: '5/1/5'
    operation_mode_night_address: '5/1/6'
    operation_mode_comfort_address: '5/1/7'

operation_mode_frost_protection_address / operation_mode_night_address / operation_mode_comfort_address are not necessary if operation_mode_address is specified.

If your device doesn't support setpoint_shift calculations (i.e. if you don't provide a setpoint_shift_address value) please set the min_temp and max_temp attributes of the climate device to avoid issues with increasing the temperature in the frontend.

The following values are valid for the operation_modes attribute:

  • Comfort (maps internally to STATE_HEAT within Home Assistant)
  • Standby (maps internally to STATE_ECO within Home Assistant)
  • Night (maps internally to STATE_IDLE within Home Assistant)
  • Frost Protection (maps internally to STATE_MANUAL within Home Assistant)
  • Fan only (maps internally to STATE_FAN_ONLY within Home Assistant)
  • Dehumidification (maps internally to STATE_DRY within Home Assistant)

{% configuration %} name: description: A name for this device used within Home Assistant. required: false default: KNX Climate type: string temperature_address: description: KNX group address for reading current room temperature from KNX bus. required: true type: string target_temperature_address: description: KNX group address for reading current target temperature from KNX bus. required: true type: string setpoint_shift_address: description: KNX address for setpoint_shift. required: false type: string setpoint_shift_state_address: description: Explicit KNX address for reading setpoint_shift. required: false type: string setpoint_shift_step: description: Defines for step size in Kelvin for each step of setpoint_shift. required: false default: 0.5 type: float setpoint_shift_min: description: Minimum value of setpoint shift. required: false default: -6 type: integer setpoint_shift_max: description: Maximum value of setpoint shift. required: false default: 6 type: integer operation_mode_address: description: KNX address for operation mode (Frost protection/night/comfort). required: false type: string operation_mode_state_address: description: Explicit KNX address for reading operation mode. required: false type: string controller_status_address: description: KNX address for HVAC controller status (in accordance with KNX AN 097/07 rev 3). required: false type: string controller_status_state_address: description: Explicit KNX address for reading HVAC controller status. required: false type: string controller_mode_address: description: KNX address for handling controller modes. required: false type: string controller_mode_state_address: description: Explicit KNX address for reading HVAC Control Mode. required: false type: string operation_mode_frost_protection_address: description: KNX address for switching on/off frost/heat protection mode. required: false type: string operation_mode_night_address: description: KNX address for switching on/off night mode. required: false type: string operation_mode_comfort_address: description: KNX address for switching on/off comfort mode. required: false type: string operation_modes: description: Overrides the supported operation modes. required: false type: array on_off_address: description: KNX address for switching the climate device on/off. required: false type: string on_off_state_address: description: KNX address for gathering the current state (on/off) of the climate device. required: false type: string min_temp: description: Override the minimum temperature. required: false type: float max_temp: description: Override the maximum temperature. required: false type: float {% endconfiguration %}