3.5 KiB
layout | title | description | date | sidebar | comments | sharing | footer | logo | ha_category | ha_release | ha_iot_class |
---|---|---|---|---|---|---|---|---|---|---|---|
page | KNX Climate | Instructions on how to integrate KNX thermostats with Home Assistant. | 2016-06-24 12:00 | true | false | true | true | knx.png | Climate | 0.25 | Local Polling |
The knx
climate platform is used as in interface with KNX thermostats.
The knx
component must be configured correctly, see KNX Component.
To use your KNX thermostats in your installation, add the following lines to your configuration.yaml
file:
# Example configuration.yaml entry
climate:
- platform: knx
name: HASS-Kitchen.Temperature
temperature_address: '5/1/1'
setpoint_shift_address: '5/1/2'
setpoint_shift_state_address: '5/1/3'
target_temperature_address: '5/1/4'
operation_mode_address: '5/1/5'
Alternatively, if your device has dedicated binary group addresses for frost/night/comfort mode:
# Example configuration.yaml entry
climate:
- platform: knx
name: HASS-Kitchen.Temperature
temperature_address: '5/1/1'
setpoint_shift_address: '5/1/2'
setpoint_shift_state_address: '5/1/3'
target_temperature_address: '5/1/4'
operation_mode_frost_protection_address: '5/1/5'
operation_mode_night_address: '5/1/6'
operation_mode_comfort_address: '5/1/7'
{% configuration %} name: description: A name for this device used within Home Assistant. required: false default: KNX Climate type: string temperature_address: description: KNX group address for reading current room temperature from KNX bus. required: true type: string target_temperature_address: description: KNX group address for reading current target temperature from KNX bus. required: true type: string setpoint_shift_address: description: KNX address for setpoint_shift. required: false type: string setpoint_shift_state_address: description: Explicit KNX address for reading setpoint_shift. required: false type: string setpoint_shift_step: description: Defines for step size in Kelvin for each step of setpoint_shift. required: false default: 0.5 type: float setpoint_shift_min: description: Minimum value of setpoint shift. required: false default: -6 type: integer setpoint_shift_max: description: Maximum value of setpoint shift. required: false default: 6 type: integer operation_mode_address: description: KNX address for operation mode (Frost protection/night/comfort). required: false type: string operation_mode_state_address: description: Explicit KNX address for reading operation mode. required: false type: string controller_status_address: description: KNX address for HVAC controller status (in accordance with KNX AN 097/07 rev 3). required: false type: string controller_status_state_address: description: Explicit KNX address for reading HVAC controller status. required: false type: string operation_mode_frost_protection_address: description: KNX address for switching on/off frost/heat protection mode. required: false type: string operation_mode_night_address: description: KNX address for switching on/off night mode. required: false type: string operation_mode_comfort_address: description: KNX address for switching on/off comfort mode. required: false type: string {% endconfiguration %}
operation_mode_frost_protection_address
/ operation_mode_night_address
/ operation_mode_comfort_address
are not necessary if operation_mode_address
is specified.